XCON: X.400 Connector Uses Session Selector on X.400 Connections |
The information in this article applies to:
-
Microsoft Exchange Server, versions 4.0, 5.0, 5.5
SYMPTOMS
If a Session Selector (S Sel) is defined for an X.400 connection defined
with X.410 conformance, communication to foreign X.400 systems may not
work properly.
The Windows NT application event log may contain the following entry:
Event ID: 51
Source: MSExchangeMTA
Description:
An unknown MTA has attempted to bind. The MTA name in bind is
<REMOTE MTA NAME>. The MTA presentation address is
/t:0x44454D4F/n:0x444545392D5443504950,
Association index: 2018. [MTA XFER-IN 35 42] (14)
CAUSE
Exchange Server incorrectly allows a configuration that sends and expects
to receive a Session Selector (S Sel) on an X.410 conformant connection if
defined to do so in the X.400 Connector Stack property pages.
The following is taken from the Red Book, X.410, Page 110, Note 2:
Message handling will not use Session Layer addressing, that is, a
session address will not be passed in the Connect SPDU of the Session
Layer.
An X.410 conformant connection is configured by choosing 1984 or 1988 X.410
mode in the message transfer agent (MTA) conformance pane of the Advanced
property page for the X.400 Connector.
Exchange should ignore the S Selector value for X.410 conformant
connections.
RESOLUTION
Exchange Server 5.0
A supported fix that corrects this problem is now available from Microsoft,
but has not been fully regression-tested and should be applied only to
systems experiencing this specific problem. If you are not severely
affected by this specific problem, Microsoft recommends that you wait for
the next Microsoft Exchange Server version 5.0 service pack that contains
this fix.
To resolve this problem immediately, contact Microsoft Product Support
Services to obtain the fix. For a complete list of Microsoft Product
Support Services phone numbers and information on support costs, please go
to the following address on the World Wide Web:
http://support.microsoft.com/support/supportnet/default.asp
The English version of this fix should have the following file attributes
or later:
Component: Message Transfer Agent (MTA)
File Name Version
-------------------------
Emsmta.exe 5.0.1461.37
Ems_rid.dll 5.0.1461.37
NOTE: If you contact Microsoft to obtain this fix, a fee may be charged.
This fee is refundable if it is determined that you only require the fix
you requested. However, this fee is non-refundable if you request
additional technical support, if your no-charge technical support period
has expired, or if you are not eligible for standard no-charge technical
support.
For more information about eligibility for no-charge technical support, see
the following article in the Microsoft Knowledge Base:
Q154871 Determining If Your Product Is Eligible for No-Charge
Technical Support
Exchange Server 5.5
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
version 5.5. This problem has been corrected in the latest U.S. service
pack for Microsoft Exchange Server version 5.5. For information on
obtaining the service pack, query on the following word in the Microsoft
Knowledge Base (without the spaces):
S E R V P A C K
WORKAROUND
To work around this problem, do not define X.400 systems with S Selector
values if X.410 conformant connections will be used. By manipulating the
OSI Protocol Information in the Stack Property Page of the X.400 Connector,
you may be able to configure the X.400 Connector to send an S Selector (if
necessary), but not to expect one in return.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
versions 4.0, 5.0, and 5.5.
Additional query words:
kbbug4.00 kbbug5.00 XFOR kbbug5.50 kbfix5.50.sp1
kbfix5.0.sp3
Keywords : XCON
Version : winnt:4.0,5.0,5.5
Platform : winnt
Issue type : kbbug