(at the controller & harddisk.)
(At the cable.)
50 PIN IDC MALE at the controller & harddisk.
50 PIN IDC FEMALE at the cable.
Pin | Name | Dir | Description |
---|---|---|---|
01 | GND | ![]() |
Ground |
02 | GND | ![]() |
Ground |
03 | +DB0 | ![]() |
+Data Bus 0 |
04 | -DB0 | ![]() |
-Data Bus 0 |
05 | +DB1 | ![]() |
+Data Bus 1 |
06 | -DB1 | ![]() |
-Data Bus 1 |
07 | +DB2 | ![]() |
+Data Bus 2 |
08 | -DB2 | ![]() |
-Data Bus 2 |
09 | +DB3 | ![]() |
+Data Bus 3 |
10 | -DB3 | ![]() |
-Data Bus 3 |
11 | +DB4 | ![]() |
+Data Bus 4 |
12 | -DB4 | ![]() |
-Data Bus 4 |
13 | +DB5 | ![]() |
+Data Bus 5 |
14 | -DB5 | ![]() |
-Data Bus 5 |
15 | +DB6 | ![]() |
+Data Bus 6 |
16 | -DB6 | ![]() |
-Data Bus 6 |
17 | +DB7 | ![]() |
+Data Bus 7 |
18 | -DB7 | ![]() |
-Data Bus Parity7 |
19 | +DBP | ![]() |
+Data Bus Parity (odd Parity) |
20 | -DBP | ![]() |
-Data Bus Parity (odd Parity) |
21 | DIFFSENS | ? | ??? |
22 | GND | ![]() |
Ground |
23 | res | - | Reserved |
24 | res | - | Reserved |
25 | TERMPWR | ![]() |
Termination Power |
26 | TERMPWR | ![]() |
Termination Power |
27 | res | - | Reserved |
28 | res | - | Reserved |
29 | +ATN | ![]() |
+Attention |
30 | -ATN | ![]() |
-Attention |
31 | GND | ![]() |
Ground |
32 | GND | ![]() |
Ground |
33 | +BSY | ![]() |
+Bus is busy |
34 | -BSY | ![]() |
-Bus is busy |
35 | +ACK | ![]() |
+Acknowledge |
36 | -ACK | ![]() |
-Acknowledge |
37 | +RST | ![]() |
+Reset |
38 | -RST | ![]() |
-Reset |
39 | +MSG | ![]() |
+Message |
40 | -MSG | ![]() |
-Message |
41 | +SEL | ![]() |
+Select |
42 | -SEL | ![]() |
-Select |
43 | +C/D | ![]() |
+Control or Data |
44 | -C/D | ![]() |
-Control or Data |
45 | +REQ | ![]() |
+Request |
46 | -REQ | ![]() |
-Request |
47 | +I/O | ![]() |
+In/Out |
48 | -I/O | ![]() |
-In/Out |
49 | GND | ![]() |
Ground |
50 | GND | ![]() |
Ground |