From: | Richard |
Date: | 3 Mar 2001 at 23:57:56 |
Subject: | Re: PFS2 wrong index block id & wrong dir block id |
--- In amigactive@y..., "Neil Bothwick" <neil@w...> wrote:
> Gerald Mellor said,
>
> >> Wrong index block id
> >> wrong dir block id
>
> > Yeah, DiskValid isn't really all that good at fixing errors like this.
> > Once they occur they tend to keep reoccurring. The only solution I've
> > found is to reformat the disk. Copy everything to a CD / Zip / other
> > partition and format that partition.
>
> That's a short term solution, the problem can recur. sometimes you only
> need to reboot to get rid of the errors, other times a reformat is
> needed. The long term solution is to upgrade to PFS3.
I found that a reboot fixed it once (I ran DiskValid and it came up with no errors)
As for the buffers, they are already at maximum, and yes I am using that partition for IB cache and YAM folders.
If I upgrade to PFS3 will I need to reformat my partitions or can I just "update file system"? I have plenty of spare empty partitions to copy files onto if I need to reformat, so I guess it doesn't really matter :)
One thing I will mention was that when I backup up Work2: onto Work3: (partitions on same drive) it took ages... Hard drive was thrashing for ages... It was alot quicker to copy from Work: (IDE drive) to Work3: (I thought I may as well back up *everything*)
Did I post that I seem to have fixed the problem now, with the physical relocation of the drive and fan blowing onto PCB side of it instead of across the top (label) side of it?