  1.  
  2.                                   Page 1 of 2
  3.  
  4.                          BTU Heating/Cooling Analysis
  5.  
  6.  
  7.    01-29-1990
  8.  
  9.    A to Z Unlimited
  10.    901 Ferndale Blvd.
  11.    High Point, NC 27262
  12.  
  13.  
  14. ****************************************************************************
  15. ****************************************************************************
  16.  
  17.    This analysis prepared especially for: John Doe
  18.  
  19.    John Doe
  20.    1234 Anywhere Ct.
  21.    High Point, NC 27260
  22.  
  23.  
  24.                           *********** HEATING ***********
  25.  
  26.        The heating outside design temperature is  10 degrees fahrenheit.
  27.        The heating  inside design temperature is  72 degrees fahrenheit.
  28.        The heating  temperature  differential is  62 degrees fahrenheit.
  29.  
  30.    The heat loss for this building is      79,616 BTU's.
  31.  
  32.    The heating unit must handle     904 CFM's for proper heating.
  33.  
  34.    Any heating unit must be rated as close as possible to the heat loss
  35.    calculated in this study, but not less than that amount.
  36.  
  37.    The above CFM allows an 80 degrees rise in inlet to outlet air temperature.
  38.  
  39.  
  40.                           *********** COOLING ***********
  41.  
  42.        The cooling outside design temperature is  95 degrees fahrenheit.
  43.        The cooling  inside design temperature is  72 degrees fahrenheit.
  44.        The cooling  temperature  differential is  23 degrees fahrenheit.
  45.  
  46.    The heat gain for this building is      43,101 BTU's.
  47.  
  48.           This translates into       3.6 tons of cooling.
  49.  
  50.    The preferred cooling CFM is   1,293 CFM's for proper cooling.
  51.  
  52.                  For high humidity areas use     1,077 CFM's
  53.                  For normal humidity areas use   1,293 CFM's
  54.                  For low humidity areas use      1,508 CFM's
  55.  
  56.    Any cooling unit must be rated as close as possible to the heat gain
  57.    calculated in this study, but not less than that amount.
  58.  
  59. ****************************************************************************
  60.    The writers of the software that was used in generating the above in-
  61.    formation assumes no responsibilities for any losses that may be 
  62.    incurred by the use of the above information.
  63.  
  64.                                   Page 2 of2
  65.  
  66.                          BTU Heating/Cooling Analysis
  67.  
  68.  
  69.    01-29-1990
  70.  
  71.    John Doe
  72.    1234 Anywhere Ct.
  73.    High Point, NC 27260
  74.  
  75.  
  76. ****************************************************************************
  77. ****************************************************************************
  78.  
  79.  
  80.      *********** Commercial analysis based on the following data ***********
  81.  
  82.    There are  18 persons used for this analysis.
  83.  
  84.    There are  10 office equipment units used for this analysis.
  85.  
  86.    There are  40 office lighting units used for this analysis.
  87.  
  88.  
  89.      *********** Structural analysis is based on the following data ***********
  90.  
  91.    Based on 1055 square feet, total exposed outside wall area.
  92.  
  93.        Wall construction is : Frame wall w/R-11. 
  94.        The wall has a heat transfer factor of .07 heating or cooling.
  95.  
  96.    Based on 2 doors, assuming 20 square feet per door.
  97.  
  98.        Door construction is : Solid wood, no storm.
  99.        The door has a heat transfer factor of .713 heating and .46 cooling.
  100.  
  101.    Based on 23 windows, assuming 15 square feet per window.
  102.  
  103.        All window construction is : Single glazed, plain, no storm. 
  104.        All windows have a heating factor of  1.505 
  105.  
  106.    There are 5 windows facing north, with a cooling factor of 30 
  107.    There are 0 windows facing northeast/west, with a cooling factor of 65 
  108.    There are 13 windows facing east/west, with a cooling factor of 90 
  109.    There are 0 windows facing southeast/west, with a cooling factor of 80 
  110.    There are 5 windows facing south, with a cooling factor of 50 
  111.  
  112.    Based on 1800 square feet total floor area.
  113.  
  114.    The foundation is : Over uncond. basement/enclosed crawl. 
  115.    The floor has a heat transfer factor of .312 heating and 0 cooling.
  116.  
  117.    The ceiling is : Ceiling under/vent. attic/uncond. room. 
  118.    Ceiling insulation is : R-11. 
  119.    The ceiling has a heat transfer factor of .088 heating and .083 cooling.
  120.  
  121. ****************************************************************************