  1.  
  2.  
  3. ***************************************************
  4. ****                                           ****
  5. **** ASC and ASCQ Assignments (byte 12 and 13) ****
  6. ****                                           ****
  7. ****                    from                   ****
  8. ****                                           ****
  9. ****               draft proposed              ****
  10. ****         American National Standard        ****
  11. ****          for information systems -        ****
  12. ****                                           ****
  13. ****    SMALL COMPUTER SYSTEM INTERFACE - 2    ****
  14. ****                 (SCSI-2)                  ****
  15. ****                                           ****
  16. ****              March 9, 1990                ****
  17. ****                                           ****
  18. ***************************************************
  19.  
  20.  
  21. 00 00 No additional sense information
  22. 00 01 Filemark detected
  23. 00 02 End-of-partition/medium detected
  24. 00 03 Setmark detected
  25. 00 04 Beginning-of-partition/medium detected
  26. 00 05 End-of-data detected
  27. 00 06 I/O process terminated
  28. 00 11 Audio play operation in progress
  29. 00 12 Audio play operation paused
  30. 00 13 Audio play operation successfully completed
  31. 00 14 Audio play operation stopped due to error
  32. 00 15 No current audio status to return
  33. 01 00 No index/sector signal
  34. 02 00 No seek complete
  35. 03 00 Peripheral device write fault
  36. 03 01 No write current
  37. 03 02 Excessive write errors
  38. 04 00 Logical unit not ready, cause not reportable
  39. 04 01 Logical unit is in process of becoming ready
  40. 04 02 Logical unit not ready, initializing command required
  41. 04 03 Logical unit not ready, manual intervention required
  42. 04 04 Logical unit not ready, format in progress
  43. 05 00 Logical unit does not respond to selection
  44. 06 00 No reference position found
  45. 07 00 Multiple peripheral devices selected
  46. 08 00 Logical unit communication failure
  47. 08 01 Logical unit communication time-out
  48. 08 02 Logical unit communication parity error
  49. 09 00 Track following error
  50. 09 01 Tracking servo failure
  51. 09 02 Focus servo failure
  52. 09 03 Spindle servo failure
  53. 0A 00 Error log overflow
  54. 0B 00
  55. 0C 00 Write error
  56. 0C 01 Write error recovered with auto reallocation
  57. 0C 02 Write error - auto reallocation failed
  58. 0D 00
  59. 0E 00
  60. 0F 00
  61. 10 00 ID CRC or ECC error
  62. 11 00 Unrecovered read error
  63. 11 01 Read retries exhausted
  64. 11 02 Error too long to correct
  65. 11 03 Multiple read errors
  66. 11 04 Unrecovered read error - auto reallocate failed
  67. 11 05 L-EC uncorrectable error
  68. 11 06 CIRC unrecovered error
  69. 11 07 Data resychronization error
  70. 11 08 Incomplete block read
  71. 11 09 No gap found
  72. 11 0A Miscorrected error
  73. 11 0B Unrecovered read error - recommend reassignment
  74. 11 0C Unrecovered read error - recommend rewrite the data
  75. 12 00 Address mark not found for id field
  76. 13 00 Address mark not found for data field
  77. 14 00 Recorded entity not found
  78. 14 01 Record not found
  79. 14 02 Filemark or setmark not found
  80. 14 03 End-of-data not found
  81. 14 04 Block sequence error
  82. 15 00 Random positioning error
  83. 15 01 Mechanical positioning error
  84. 15 02 Positioning error detected by read of medium
  85. 16 00 Data synchronization mark error
  86. 17 00 Recovered data with no error correction applied
  87. 17 01 Recovered data with retries
  88. 17 02 Recovered data with positive head offset
  89. 17 03 Recovered data with negative head offset
  90. 17 04 Recovered data with retries and/or CIRC applied
  91. 17 05 Recovered data using previous sector ID
  92. 17 06 Recovered data without ECC - data auto-reallocated
  93. 17 07 Recovered data without ECC - recommend reassignment
  94. 18 00 Recovered data with error correction applied
  95. 18 01 Recovered data with error correction and retries applied
  96. 18 02 Recovered data - data auto-reallocated
  97. 18 03 Recovered data with CIRC
  98. 18 04 Recovered data with LEC
  99. 18 05 Recovered data - recommend reassignment
  100. 19 00 Defect list error
  101. 19 01 Defect list not available
  102. 19 02 Defect list error in primary list
  103. 19 03 Defect list error in grown list
  104. 1A 00 Parameter list length error
  105. 1B 00 Synchronous data transfer error
  106. 1C 00 Defect list not found
  107. 1C 01 Primary defect list not found
  108. 1C 02 Grown defect list not found
  109. 1D 00 Miscompare during verify operation
  110. 1E 00 Recovered id with ECC correction
  111. 1F 00
  112. 20 00 Invalid command operation code
  113. 21 00 Logical block address out of range
  114. 21 01 Invalid element address
  115. 22 00 Illegal function (should use 20 00, 24 00, or 26 00)
  116. 23 00
  117. 24 00 Invalid field in CDB
  118. 25 00 Logical unit not supported
  119. 26 00 Invalid field in parameter list
  120. 26 01 Parameter not supported
  121. 26 02 Parameter value invalid
  122. 26 03 Threshold parameters not supported
  123. 27 00 Write protected
  124. 28 00 Not ready to ready transition (medium may have changed)
  125. 28 01 Import or export element accessed
  126. 29 00 Power on, reset, or bus device reset occurred
  127. 2A 00 Parameters changed
  128. 2A 01 Mode parameters changed
  129. 2A 02 Log parameters changed
  130. 2B 00 Copy cannot execute since host cannot disconnect
  131. 2C 00 Command sequence error
  132. 2C 01 Too many windows specified
  133. 2C 02 Invalid combination of windows specified
  134. 2D 00 Overwrite error on update in place
  135. 2E 00
  136. 2F 00 Commands cleared by another initiator
  137. 30 00 Incompatible medium installed
  138. 30 01 Cannot read medium - unknown format
  139. 30 02 Cannot read medium - incompatible format
  140. 30 03 Cleaning cartridge installed
  141. 31 00 Medium format corrupted
  142. 31 01 Format command failed
  143. 32 00 No defect spare location available
  144. 32 01 Defect list update failure
  145. 33 00 Tape length error
  146. 34 00
  147. 35 00
  148. 36 00 Ribbon, ink, or toner failure
  149. 37 00 Rounded parameter
  150. 38 00
  151. 39 00 Saving parameters not supported
  152. 3A 00 Medium not present
  153. 3B 00 Sequential positioning error
  154. 3B 01 Tape position error at beginning-of-medium
  155. 3B 02 Tape position error at end-of-medium
  156. 3B 03 Tape or electronic vertical forms unit not ready
  157. 3B 04 Slew failure
  158. 3B 05 Paper jam
  159. 3B 06 Failed to sense top-of-form
  160. 3B 07 Failed to sense bottom-of-form
  161. 3B 08 Reposition error
  162. 3B 09 Read past end of medium
  163. 3B 0A Read past beginning of medium
  164. 3B 0B Position past end of medium
  165. 3B 0C Position past beginning of medium
  166. 3B 0D Medium destination element full
  167. 3B 0E Medium source element empty
  168. 3C 00
  169. 3D 00 Invalid bits in identify message
  170. 3E 00 Logical unit has not self-configured yet
  171. 3F 00 Target operating conditions have changed
  172. 3F 01 Microcode has been changed
  173. 3F 02 Changed operating definition
  174. 3F 03 Inquiry data has changed
  175. 40 00 RAM failure (should use 40 NN)
  176. 40 NN Diagnostic failure on component NN (80H-FFH)
  177. 41 00 Data path failure (should use 40 NN)
  178. 42 00 Power-on or self-test failure (should use 40 NN)
  179. 43 00 Message error
  180. 44 00 Internal target failure
  181. 45 00 Select or reselect failure
  182. 46 00 Unsuccessful soft reset
  183. 47 00 SCSI parity error
  184. 48 00 Initiator detected error message received
  185. 49 00 Invalid message error
  186. 4A 00 Command phase error
  187. 4B 00 Data phase error
  188. 4C 00 Logical unit failed self-configuration
  189. 4D 00
  190. 4E 00 Overlapped commands attempted
  191. 4F 00
  192. 50 00 Write append error
  193. 50 01 Write append position error
  194. 50 02 Position error related to timing
  195. 51 00 Erase failure
  196. 52 00 Cartridge fault
  197. 53 00 Media load or eject failed
  198. 53 01 Unload tape failure
  199. 53 02 Medium removal prevented
  200. 54 00 SCSI to host system interface failure
  201. 55 00 System resource failure
  202. 56 00
  203. 57 00 Unable to recover table-of-contents
  204. 58 00 Generation does not exist
  205. 59 00 Updated block read
  206. 5A 00 Operator request or state change input (unspecified)
  207. 5A 01 Operator medium removal request
  208. 5A 02 Operator selected write protect
  209. 5A 03 Operator selected write permit
  210. 5B 00 LOG exception
  211. 5B 01 Threshold condition met
  212. 5B 02 LOG counter at maximum
  213. 5B 03 LOG list codes exhausted
  214. 5C 00 RPL status change
  215. 5C 01 Spindles synchronized
  216. 5C 02 Spindles not synchronized
  217. 5D 00
  218. 5E 00
  219. 5F 00
  220. 60 00 Lamp failure
  221. 61 00 Video acquisition error
  222. 61 01 Unable to acquire video
  223. 61 02 Out of focus
  224. 62 00 Scan head positioning error
  225. 63 00 End of user area encountered on this track
  226. 64 00 Illegal mode for this track
  227. 65 00
  228. 66 00
  229. 67 00
  230. 68 00
  231. 69 00
  232. 6A 00
  233. 6B 00
  234. 6C 00
  235. 6D 00
  236. 6E 00
  237. 6F 00
  238. 70 00
  239. 71 00
  240. 72 00
  241. 73 00
  242. 74 00
  243. 75 00
  244. 76 00
  245. 77 00
  246. 78 00
  247. 79 00
  248. 7A 00
  249. 7B 00
  250. 7C 00
  251. 7D 00
  252. 7E 00
  253. 7F 00
  254.