home *** CD-ROM | disk | FTP | other *** search
/ Simtel MSDOS 1992 June / SIMTEL_0692.cdr / msdos / desqview / xdvee11.arc / REMMSYS.BUG < prev    next >
Text File  |  1989-01-16  |  2KB  |  29 lines

  1.                         REMM.SYS 4.X AND DESQVIEW 2.XX
  2.  
  3.  
  4. Users of DESQview 2.01 (or above) may experience system lock-up when using a
  5. version of REMM.SYS of 4.10 (or above).  The lock-up occurs when running an
  6. interrupt-intensive application such as a serial communications program.
  7.  
  8. The reason that this particular combination causes this symptom lies in the
  9. fact that the LIM 4.0 functions are being executed in software, requiring a
  10. large amount of processing time.  This amount of overhead becomes critical
  11. when processing time must also be devoted to servicing the stream of
  12. interrupts generated by a communications program.  Any application that must
  13. devote a great deal of time to both expanded memory operations and serial
  14. communications will eventually be unable to keep pace and cease to function.
  15.  
  16. It is recommended that those users who operate in this environment and
  17. experiencing problems, replace the 4.xx version of the REMM.SYS driver with a
  18. 3.xx version.  For AST Systems products, version 3.50 of REMM.SYS is
  19. recommended.  For AST board-level expanded memory products version 3.10 of
  20. REMM.SYS will operate in this environment.
  21.  
  22. Those users with expanded memory hardware which fully supports the LIM 4.0
  23. Specification, (i.e., AST RAMpage Plus/286 or AST Premium/286 using Advanced
  24. FastRAM), will not experience any of the difficulties outlined here.
  25.  
  26. Please note: It advisable to verify that the correct DESQview configuration