* CLIPMEM.PRG
*
* Date: February 1987
* Author: David Morgan
* Notes: Simulates Clipper Autumn '86 memory allocation
* groundrules explained in Nantucket News, Autumn
* 1986, p. 4.
* Requires DOS 3.x or greater for assembly routines
*
* Input: configuration information about machine environment
* as follows --
*
* tot_conv = amount of conventional memory installed (K)
* tot_exp = amount of expanded memory installed
* dos_size = size of DOS as loaded at runtime
* load_module = size of your application's load module
* CLIPPER = copy of the runtime CLIPPER environment
* string
*
* Output: memory allocation/distribution information as follows
*
* X = amt of mem excluded
* mem_vars = amt of mem devoted to storing memvars
* run_space = amt of mem for RUNning/perhaps indexing
* pool = amt of memory devoted to free pool
* exp_space = amt of expanded mem. devoted to indexing
* if zero, indexing shares run_space
* otherwise run_space is for exclusive use
* by RUN commands
*
PARAMETERS tot_conv,tot_exp,dos_size,load_module
param_count = PCOUNT()
CLEAR
CLIPPER=UPPER(GETE('CLIPPER')+' ')
numerals = '1234567890'
params = 'VREX'
error = .F.
DO CASE
CASE param_count=0 && get parameters from this machine
tot_conv = MEM_AMT()
tot_conv = 16 * iif(tot_conv<0,65536+tot_conv,tot_conv) / 1024
tot_conv = (INT(tot_conv+.5))
tot_exp = 16*EM_AMT()
dos_size = 16*DOS_SIZ()/1024
dos_size = (INT(dos_size+.5))
load_module = 0
@ 6,0
TEXT
CLIPMEM will read remaining memory configuration parameters
from this machine.
Alternative calling syntax you may use to specify parameters
yourself, reflecting any machine:
CLIPMEM tot_conv tot_exp dos_size load_module
ENDTEXT
@ 4,0 SAY 'What is the load module size? ' GET load_module;
RANGE 100,600
READ
CASE param_count=4 && take parameters from command line
tot_conv=VAL(tot_conv)
tot_exp=VAL(tot_exp)
dos_size=VAL(dos_size)
load_module =VAL(load_module)
OTHERWISE
DO TERMINATE
ENDCASE
* range checking
DO CASE
CASE tot_conv<256 .OR. tot_conv>640
error = .T.
CASE tot_exp<0 .OR. tot_exp>8192
error = .T.
CASE dos_size<20 .OR. dos_size>200
error = .T.
CASE load_module<100 .OR. load_module>600
error = .T.
ENDCASE
IF error
DO TERMINATE
ENDIF
* analyze CLIPPER string
p2 = 1
DO WHILE p2 <= 4
curr_par = SUBSTR(params, p2, 1)
error = .F.
IF AT('&curr_par',CLIPPER)>0
p1 = AT('&curr_par',CLIPPER)+1
no_chars = 0
DO WHILE SUBSTR(CLIPPER,P1,1)$numerals
no_chars = no_chars + 1
p1 = p1 + 1
ENDDO
error = IIF(no_chars=0, .T., .F.)
IF .NOT.error
&curr_par = VAL(SUBSTR(CLIPPER,p1-no_chars,no_chars))
ELSE
CLEAR
? 'Error in CLIPPER string format. Calculation canceled.'
CANCEL
ENDIF
ELSE
&curr_par=0
ENDIF
p2 = p2 + 1
ENDDO :p2<=4
* follow the groundrules to calculate each memory category
left_over = tot_conv - dos_size - load_module
excluded = X
left_over = left_over - excluded
pool=24
left_over = left_over - pool
mem_vars = IIF(V>0,V,IIF( .2*left_over > 44 , 44, .2*left_over))
left_over = left_over - mem_vars
run_space = IIF(R > 0 , R, left_over/3 )
run_space = IIF(tot_exp=0.AND.run_space < 16, 16, run_space)
left_over = left_over - run_space
pool = pool + left_over
IF AT('E',CLIPPER) > 0 && 'E' param present
IF E=0
exp_space = 0
ELSE
exp_space = E && E specified, but
* can't exceed 1MB:
exp_space = IIF(exp_space>1024, 1024, exp_space)
* or EMM total:
exp_space = IIF(exp_space>tot_exp, tot_exp, exp_space)
* need 16K at least:
exp_space = IIF(exp_space<16, 0, exp_space)
ENDIF
ELSE && no 'E' param
exp_space = IIF(tot_exp>1024, 1024, tot_exp) && gets all EMM
exp_space = IIF(exp_space<16, 0, exp_space) && up to 1MB
ENDIF
IF mem_vars<=0.OR.pool<=0
DO TERMINATE
ENDIF
* print results
CLEAR
? "Approximate Memory Distribution for Clipper Autumn '86"
?
? 'Configuration:'
? ' Installed conventional memory: '+STR(tot_conv)
? ' Installed expanded memory: '+STR(tot_exp)
? ' DOS memory consumption: '+STR(dos_size)
? ' Application memory consumption: '+STR(load_module)
? ' CLIPPER environment string: '
IF ' '=CLIPPER
?? 'NONE'
ELSE
?? CLIPPER
ENDIF
?
? 'Conventional Memory:'
? SUBSTR(' DOS'+SPACE(20),1,20)+STR(dos_size)
? SUBSTR(' Application module'+SPACE(20),1,20)+STR(load_module)
? SUBSTR(' Excluded'+SPACE(20),1,20)+STR(X)
? SUBSTR(' Memory variables'+SPACE(20),1,20);
+STR(INT(mem_vars+.5))
IF exp_space > 0
? SUBSTR(' RUN'+SPACE(20),1,20)+STR(INT(run_space+.5))
ELSE
? SUBSTR(' RUN+Indexing'+SPACE(20),1,20)+STR(INT(run_space+.5))
ENDIF
? SUBSTR(' Free pool'+SPACE(20),1,20)+STR(INT(pool+.5))
?
? 'Expanded Memory:'
? SUBSTR(' Indexing'+SPACE(20),1,20)+STR(exp_space)
?
? '>>> All values approximate <<<'
@ 22,0
QUIT
PROCEDURE TERMINATE
CLEAR
?? CHR(7)
TEXT
Error occurred. Calling syntax is either:
CLIPMEM tot_conv tot_exp dos_size load_module (no commas)
or
CLIPMEM
You must supply either 4 or 0 command line parameters. If you do not
supply them they are read internally from the current machine or
you are prompted for them. The current CLIPPER string is read from memory.
Requires DOS 3.x or greater. Calculated values must be positive.
Significance of parameters: Allowed Range
tot_conv = amount of conventional memory installed (K) 256 - 640
tot_exp = amount of expanded memory installed 0 - 8192
dos_size = size of DOS as loaded at runtime 20 - 200
load_module = size of your application's load module 100 - 600
CLIPPER = copy of the runtime CLIPPER environment string
ENDTEXT
@ 22,0
QUIT
RETURN