CSD APAR KEYWORD COMPONENT ABSTRACT
------- ------- -------- --------- --------------------------------------
UR22624 IR79395 ABEND XMA2EMS PS/2 mod 50Z cannot use DOS 4.00 EMS
UR22624 IR79403 INCORROUT APPEND APPEND /PATH:OFF not working properly
UR22624 IR79404 WAIT IBMBIO INT 2FH for INT 67H causes hang
UR22624 IR79405 INCORROUT SHELLC SHELL HELP index entries not alphabetic
UR22624 IR79406 INCORROUT MODE MODE overwrites user's application
UR22624 IR79407 INCORROUT SELECT Using CTRL/BREAK with SHELL can hang
UR22624 IR79408 INCORROUT MODE MODE allows 19200 rate on PS/2 mod 25,30
UR22624 IR79409 MSGPANEL SHELLC SHIFT+F9= overlays F10=
UR22624 IR79410 INCORROUT SHELLC Pull down menu in files gives wrong help
UR22624 IR79411 INTEG IBMDOS BUFFERS=XX /X problem (BUFFERS to XMA)
UR22624 IR79413 INCORROUT SHELLC SHELL place hdwr cursor with selection
UR22624 IR79415 INCORROUT IBMDOS problem copying large files across NET
UR22624 IR79416 MSG PRINT First time PRINT non-exist file msg
UR22624 IR79417 INCORROUT SHELLC SHELL does not give error for / or \
UR22624 IR79423 MSG SELECT Listing of printers should be reordered
UR22624 IR79425 ABEND XMA2EMS Hangs with Token Ring NET CARD in slot 0
UR22624 IR79426 ABEND SHELLC SHELL will not run after run Comp. BASIC
UR22624 IR79427 MSG MODE MODE not handling trans. correctly
UR22624 IR79428 MSG SHELLC SHELL not handling trans. correctly
UR22624 IR79429 MSG SELECT SELECT correct defaults for keyboards
UR22624 IR79430 ABEND SELECT SELECT/SHELL translated too big for 256K
UR22624 IR79459 * INCORROUT SHELL PS/2 mod 30 with 8512 error color change
UR22624 IR79460 UNPRED XMA2EMS Unpredictable results using DMA to EMS
-------------------------------------------------------------------------------
PTF Identifier ....... UR22624 Last Changed ........ 88/09/08
AVAIL. AS CORRECTIVE SVC. - - - -
PTF UR22803 IP PAGE FULL
Environment: 400
Component .......... 560119301 Date Available ...... 88/09/08
Release .................. 400 PTF Status ........ CLOSED COR
Superseded by PTF .... Volume identifier ....... 1301
PE APAR LIST:
MODULES/MACROS: XMA2EMS APPEND IBMBIO SHELLC MODE
SELECT IBMDOS IFSFUNC PRINT KEYBOARD SHELL
APPLICABLE RELEASE: AR400
ENVIRONMENT: DOS
APARS FIXED: IR79395 IR79403 IR79404 IR79405 IR79406
IR79407 IR79408 IR79409 IR79410 IR79411 IR79413 IR79415
IR79416 IR79417 IR79423 IR79425 IR79426 IR79427 IR79428
IR79429 IR79430 IR79459 IR79460
SUPERSEDES:
PRE-REQS/CO-REQS:
COMMENTS:
APPLICABLE LEVEL: 400
------------------------------------------------------------------------
Apar Identifier ...... IR79395 Last Changed ........ 88/09/08
PS/2 MOD 50Z WITH 2MB ON PLANAR CANNOT USE DOS 4.00 EMS
Reported Symptom AB ABEND Status ........... CLOSED PER
Severity ................... 2 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
A PS/2 MODEL 50Z WITH A 2MB SIP ON THE PLANAR CANNOT USE EMS.
THE ERROR RETURNED FROM CONFIG.SYS IS EXPANDED MEMORY NOT
AVAILABLE . THIS ERROR DOES NOT OCCUR IF A 1MB SIP IS INSTALLED
ON THE PLANAR.
LOCAL FIX:
PROBLEM SUMMARY: XMA2EMS DID NOT SUPPORT 2MB ON THE PLANAR.
PROBLEM CONCLUSION: XMA2EMS HAS BEEN MODIFIED TO SUPPORT 2MB
PLANAR. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: XMA2EMS PS25060 EMSINIT
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
-----------------------------------------------------------------------
Apar Identifier ...... IR79403 Last Changed ........ 88/09/08
DOS 4.00 APPEND /PATH:OFF NOT WORKING PROPERLY
Reported Symptom IN INCORROUT Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
IF APPEND IS SET SO THAT ITS PATH IS OFF AND SEARCH & PROCESS
IS ON: APPEND /PATH:OFF /X:ON
PATH IS NULL: PATH=:
THEN A PROGRAM IN THE APPEND STRING OF DIRECTORIES IS NOT FOUND.
LOCAL FIX:
PROBLEM SUMMARY: /PATH AND /X ARE TWO DISTINCT AND SEPARATE THIN
GS.
PROBLEM CONCLUSION: CODE CORRECTED.
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: APPEND
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79404 Last Changed ........ 88/09/08
DOS 4.00 INT 2FH FOR INT 67H HOOK CAUSES HANG
Reported Symptom UN WAIT Status ........... CLOSED PER
Severity ................... 2 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
WHEN THE FOLLOWING CONFIG.SYS IS INVOKED THE SYSTEM WILL HANG:
DEVICE=XMA2EMS.SYS FRAME=C000
BUFFERS=15,4 /X
LOCAL FIX:
PROBLEM SUMMARY: WHEN BUFFERS TELLS THE INT 2FH INTERFACE THAT
IT IS A FFH PAGE USER, EVEN THOUGH A LOGICAL FFH IS NOT
AVAILABLE, INT 2FH RETURNS A BOGUS PAGE. BUFFERS BELIEVES
EVERYTHING IS ALRIGHT AND PROCEEDS IN EMS MEMORY.
PROBLEM CONCLUSION: A MODIFICATION TO LOGIC THAT CHECKS THE
ARRAY FOR THE PRESENCE OF A PAGE FOR BUFFERS. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SYSCONF
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79405 Last Changed ........ 88/09/08
DOS 4.00 SHELL HELP HAS SOME INDEX ENTRIES NOT ALPHABETIZED
Reported Symptom IN INCORROUT Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
FOUR ENTRIES IN THE SHELL HELP INDEX ARE NOT ALPHABETIZED:
MULTIPLE FILE LIST
SINGLE FILE LIST
SYSTEM FILE LIST
ARRANGE HELP
LOCAL FIX:
PROBLEM SUMMARY: ENTRIES REWORDED BUT NOT RE-ALPHABETIZED.
PROBLEM CONCLUSION: RE-ALPHABETIZED. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: USAINC
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79406 Last Changed ........ 88/09/08
DOS 4.00 MODE OVERWRITES USER S APPLICATION
Reported Symptom UN INCORROUT Status ........... CLOSED PER
Severity ................... 2 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
MODE ASSUMES DS SEGMENT, WHEN DS IS STILL SET TO THE USER S DS V
ALUE. USER S APPLICATION IS OVERWRITTEN.
LOCAL FIX:
PROBLEM SUMMARY: INTERNAL VARIABLE RETRY FLAG DID NOT HAVE
A CORRECT CODE SEGMENT OVERRIDE FOR THE ASSUME STATEMENT THAT
PRECEDED IT.
PROBLEM CONCLUSION: A CS: OVERRIDE WAS INCLUDED SO THE
VARIABLE WAS STORED ADN RETRIEVED CORRECTLY IN THE MODE RESIDENT
SEGMENT. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: RESCODE
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79407 Last Changed ........ 88/09/08
DOS 4.00 USING CTRL/BREAK WITH THE SHELL CAN HANG THE SYSTEM
Reported Symptom UN INCORROUT Status ........... CLOSED PER
Severity ................... 2 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
CTRL/BREAK CAN HANG THE SYSTEM UNDER THE FOLLOWING CONDITIONS:
1. BRING UP THE SHELL
2. GO TO THE COMMAND LINE AND TURN BREAK ON
3. RETURN TO THE SHELL AND PRESS CTRL/BREAK.
ALSO RUNNING A PROGRAM OR BATCH FILE THAT TURNS BREAK ON WILL GI
VE THE SAME RESULTS.
LOCAL FIX:
PROBLEM SUMMARY: DOSSHELL.BAT SHOULD CONTAIN BREAK=OFF
PROBLEM CONCLUSION: ADD @BREAK=OFF AFTER :COMMON STATEMENT
IN DOSSHELL.BAT. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SELECT0 GENCOMS
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79408 Last Changed ........ 88/09/08
DOS 4.00 MODE ALLOWS RATE OF 19200 TO BE SET ON PS/2 MOD 25,30
Reported Symptom IN INCORROUT Status ........... CLOSED PER
Severity ................... 4 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
MODE ALLOWS PS/2 MOD 25 AND MOD 30 MACHINES, WITH MAXIMUM
9600 RATE, TO BE SET TO RATE OF 19200.
LOCAL FIX:
PROBLEM SUMMARY: MODEL BYTE OF PS/2 MOD 25 AND MOD 30 SAME AS
MODEL BYTE OF ANOTHER MACHINE THAT SUPPORTS 19200 RATE.
PROBLEM CONCLUSION: USED CODING SEQUENCE THAT WILL DISTINQUISH
808X-BASED MACHINES. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: MODEPARS
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79409 Last Changed ........ 88/09/08
DOS 4.00 SHIFT+F9=COMMAND PROMPT OVERLAYS F10=ACTIONS
Reported Symptom MS MSGPANEL Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
THE SHIFT+F9=COMMAND PROMPT ON THE LAST LINE OF THE SHELL PANELS
OVERLAYS PART OF THE F10=ACTIONS ON THE SAME LINE.
LOCAL FIX:
PROBLEM SUMMARY: THE PANEL TO DISPLAY SHIFT+F9 HAS TO BE MADE
RELATIVE TO THE F10 PANEL. IT IS CURRENTLY IN STATIC POSITION
15.
PROBLEM CONCLUSION: EQUATE FOR LOCATION OF SHIFT+F9 PANEL MADE
RELATIVE TO F10 ENDING POSITION. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SHELLDA
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79410 Last Changed ........ 88/09/08
DOS 4.00 PULL DOWN MENU IN FIELS GIVES WRONG HELP TEXT BACKWARDS
Reported Symptom IN INCORROUT Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
WHEN YOU ARE IN THE SHELL FIEL SYSTEM AND CHOOSE FILE, YOU GET A
PULL DOWN PANEL TEXT STARTING WITH OPEN. IF YOU GO DIRECTLY TO
THE BOTTOM LINE WITH THE ARROW UP KEY (WRAPPING AROUND) AND THE
N LOOK AT THE HELP TEXT (F1) YOU DO NOT SEE THE CORRECT ONE. YOU
SEE THE HELP FOR THE CHOICE ABOVE. THIS ONLY OCCURS WHEN GOING
UP, NOT STARTING FROM THE TOP.
LOCAL FIX:
PROBLEM SUMMARY: HELP TEXT NOT BEING CORRECTLY POINTED TO.
PROBLEM CONCLUSION: CHANGED CODE TO SET THE CORRECT HELP TEXT
FOR THE LAST ENTRY ON THE FILE PULLDOWN. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SHELLRD
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79411 Last Changed ........ 88/09/08
DOS 4.00 BUFFERS=XX /X PROBLEM (BUFFERS TO XMA)
Reported Symptom UN INTEG Status ........... CLOSED PER
Severity ................... 2 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
WHEN IN CONFIG.SYS YOU HAVE:
BUFFERS=XX /X
TO PUT IBMDOS FILE BUFFERS IN EXTENDED MEMORY, DATA MAY GET CORRU
PTED BECAUSE DOS DOES NOT SAVE AND RESTORE XMA MAPPING FOR
BUFFERS.
LOCAL FIX:
PROBLEM SUMMARY: DOS DOES NOT SAVE AND RESTORE XMA MAPPING FOR
BUFFERS.
PROBLEM CONCLUSION: RE-MAP EXTENDED MEMORY FOR EACH USE OF THE
BUFFERS. MOVE THE VARIABLE FOR THIS TO IBMDOS SWAPPABLE DATA
AREA. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: DISP MKNODE MSTABLE MSDATA
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79413 Last Changed ........ 88/09/08
DOS 4.00 SHELL PLACE THE HARDWARE CURSOR IN THE ACTION BAR.
Reported Symptom IN INCORROUT Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
IN THE SHELL, THE HARDWARE CURSOR SHOULD BE PLACED WITHIN THE
CURRENT ACTION BAR.
LOCAL FIX:
PROBLEM SUMMARY: HARDWARE CURSOR IS NOT KEPT WITH SELECTION
CURSOR.
PROBLEM CONCLUSION: SUPPORT ADDED TO ALLOW THE HARDWARE CURSOR
TO FOLLOW THE SELECTION CURSOR. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SHELLRD
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79415 Last Changed ........ 88/09/08
DOS 4.00 PROBLEM WITH COPYING LARGE FILES ACROSS NETWORK USING
SHELL
Reported Symptom IN INCORROUT Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
WHEN YOU ARE RUNNING THE SHELL AND COPY A LARGE FILE THAT
ALREADY EXISTS ON A NETWORK DRIVE, YOU GET A GENERAL ERROR
MESSAGE. HOWEVER IF YOU SWITCH TO THE COMMAND LINE YOU CAN COPY
THE FILE.
LOCAL FIX:
PROBLEM SUMMARY: PROBLEM IN FAT ALLOCATION ROUTINE.
PROBLEM CONCLUSION: CORRECTED FAT ALLOCATION ROUTINE.
PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: ROM
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79416 Last Changed ........ 88/09/08
DOS 4.00 FIRST TIME PRINT WITH NON-EXIST FILE GARBLED MESSAGE
APPEARS.
Reported Symptom UN MSG Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
IF PRINT NONEXIST.FIL IS TYPED TO LOAD PRINT FOR THE FIRST
TIME AND THE FILE DOES NOT EXIST, INSTEAD OF GETTING THE
MESSAGE FILE NOT FOUND - X:\NONEXIST.FIL , YOU GET %$#*& - X:\
NONEXIST.FIL . %$#*& MAY BE ANY COMBINATION OF GARBAGE.
LOCAL FIX:
PROBLEM SUMMARY: FIRST TIME PRINT IS LOADED, TRANSIENT PART
MOVED OUT TO MAKE ROOM FOR THE PRINT QUEUE AND PRINT BUFFER.
TRANSIENT PORTION THAT IS MOVE OUT CONTAINS ALL OF THE
MESSAGE CODE. MESSAGE CODE IS LINKED INTO PRINT AS NEAR SO AS
TO ISOLATE IT FROM THE SEGMENT MOVE. MESSAGE RETRIEVER KEEPS
TRACK OF OFFSET AND SEGMENT FOR EXTENDED AND PARSE ERRORS.
PROBLEM CONCLUSION: CALL SYSLOADMSG A SECOND TIME, IMMEDIATELY
AFTER THE MOVE. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: PRINTT PRINT
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79417 Last Changed ........ 88/09/08
DOS 4.00 SHELL DOES NOT GIVE ERROR MSG FOR / AND \ IN CREATE
DIRECTORY FIELD.
Reported Symptom IN INCORROUT Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
IF / OR \ IS ENCOUNTERED IN THE CREATE DIRECTORY FIELD,
DISPLAY AN ERROR MESSAGE.
LOCAL FIX:
PROBLEM SUMMARY: BACKSLASHES NOT PARSED AS AN ERROR.
PROBLEM CONCLUSION: BACKSLASHES PARSED AS ERROR AND ERROR
MESSAGE DISPLAYED. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SHELLC
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79423 Last Changed ........ 88/09/08
DOS 4.00 LISTING OF PRINTERS ON SELECT MENU SHOULD BE RE-ORDERED
Reported Symptom MS MSG Status ........... CLOSED PER
Severity ................... 4 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
THE 5204 QUICKWRITER PRINTER (SERIAL) SHOULD BE AFTER THE
PARALLEL ENTRY IN THE SELECTION LIST OF THE PRINTER MENU. OTHER
PRINTERS ARE LISTED WITH PARALLEL FIRST. ALSO PUT ALL PRINTERS
IN NUMERICAL ORDER.
LOCAL FIX:
PROBLEM SUMMARY: LISTING OF THE PRINTERS NOT CONSISTENT WITH
EACH OTHER. PARALLEL PRINTERS SHOULD COME BEFORE SERIAL PRINTER
PROBLEM CONCLUSION: PRINTERS REARRANGED INTO TWO GROUPS IN
ASCENDING NUMERICAL ORDER IN EACH GROUP.
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: USA.PRT
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79425 Last Changed ........ 88/09/08
DOS 4.00 HANGS WITH TOKEN RING NETWORK CARD IN SLOT 0
Reported Symptom AB ABEND Status ........... CLOSED PER
Severity ................... 2 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
WHEN XMA2EMS IS LOADED WITH AN IBM 2MB EXPANDED MEMORY ADAPTER/
IBM PS/2 80286 EXPANDED MEMORY ADAPTER/A/IBM PS/2 80286 MEMORY
EXPANSION OPTION IN SLOT 4 AND A TOKEN RING NETWORK CARD IN SLOT
0, THE SYSTEM HANGS.
LOCAL FIX:
PROBLEM SUMMARY: XMA2EMS ACCESSED PAST THE LAST VALID SLOT
DESCRIPTOR ENTRY IN THE TABLE THAT DEINES EACH SLOT. SINCE ALL
ENTRIES ARE INITIALIZED TO 0, XMA2EMS ATTEMTPED TO ACCESS SLOT 0
WHEN A CARD OTHER THAN THE CORRECT MEMORY ADAPTER CARD IS
ADDRESSED, PROBLEMS CAN ARISE.
PROBLEM CONCLUSION: MODIFY XMA2EMS TO NOT ACCESS TABLE ENTRIES
BEYOND THE LAST VALID ENTRY FOR SLOT INFORMATION. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: XMA2EMS PS25060
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79426 Last Changed ........ 88/09/08
DOS 4.00 SHELL WILL NOT RUN AFTER RUNNING A COMPILED BASIC
PROGRAM
Reported Symptom AB ABEND Status ........... CLOSED PER
Severity ................... 2 Date Closed ......... 88/08/04
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
AFTER RUNNING ANY COMPILED BASIC PROGRAMS, THE SHELL CANNOT BE B
ROUGHT UP. THE SYSTEM HANGS OR OTHER STRANGE THINGS OCCUR.
LOCAL FIX:
PROBLEM SUMMARY: AN INT 3 WAS INCLUDED IN THE SHELL CODE.
COMPILED BASIC PROGRAMS DO NOT RESTORE INT 3 AFTER BEING RUN.
THE INT3 IN THE SHELL WAS REMOVED.
PROBLEM CONCLUSION: THE INT3 IN THE SHELL CODE WAS REMOVED.
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SHELLRD INC
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79427 Last Changed ........ 88/09/08
DOS 4.00 MODE NOT HANDLING TRANSLATIONS CORRECTLY
Reported Symptom MS MSG Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
MODE MESSAGES ARE BEING TRUNCATED WHEN TRANSLATED AND NOT
HANDLING THE Y/N PROMPT CORRECTLY.
LOCAL FIX:
PROBLEM SUMMARY: MODE CHECKS FOR Y OR N . MAXIMUM FIELD
LENGTHS NOT ALLOWING FOR TRANSLATIONS.
PROBLEM CONCLUSION: USE INT21 CALL TO CHECK FOR Y/N RESPONSE.
CORRECT MXIMUM FIELD LENGTHS FOR MESSAGE RETRIEVER. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: MODESCRN MODESUBS
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79428 Last Changed ........ 88/09/08
DOS 4.00 SHELL NOT HANDLING TRANSLATED MESSAGES CORRECTLY
Reported Symptom MS MSG Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
SOME MESSAGE AND PANELSTOO SMALL TO HANDLE TRANSLATED MESSAGES
AND PANELS.
LOCAL FIX:
PROBLEM SUMMARY: FIELD LENGTH USED IN CODE NOT BIG ENOUGH TO
HANDLE TRANSLATIONS.
PROBLEM CONCLUSION: FIELD LENGTHS CHANGED. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SHDOSDIS SHELLRD
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79429 Last Changed ........ 88/09/08
DOS 4.00 SELECT MUST CORRECT DEFAULTS FOR COUNTRY KEYBOARD IDS
Reported Symptom MS MSG Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
SELECT MUST CORRECT THE HIGHLIGHTED DEFAULTS FOR UK, FRANCE, AND
ITALY FOR THE KEYBOARD IDS.
LOCAL FIX:
PROBLEM SUMMARY: DEFAULTS FOR COUNTRY KEYBOARD IDS INCORRECT.
PROBLEM CONCLUSION: CHANGE THE DEFAULT INDEX FOR ALTERNATE
KEYBOARDS. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: KDFNOW SELECT0 SELECT1 SELECT2 USAINF
ROUTINES VAR GEN_COMS
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79430 Last Changed ........ 88/09/08
DOS 4.00 SELECT/SHELL WHEN TRANSLATED TOO BIG FOR 256KB MACHINE
Reported Symptom AB ABEND Status ........... CLOSED PER
Severity ................... 2 Date Closed ......... 88/08/05
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
WHEN TRANSLATED, THE SHELL AND SELECT WILL NOT RUN ON A 256KB
MACHINE. GET MESSAGE SAYING NOT ENOUGH MEMORY OR PROGRAM TOO
BIG TO FIT IN MEMORY.
LOCAL FIX:
PROBLEM SUMMARY: SIZE OF COMPONENTS INCREASED WITH TRANSLATION.
PROBLEM CONCLUSION: SIZE REDUCED AS MUCH AS POSSIBLE IN SELECT
AND SHELL. A SYSTEM FULLY CONFIGURED FOR NLS SUPPORT WILL
REQUIRE 320KB MINIMUM. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SELECT0 PCINPUT
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79459 Last Changed ........ 88/09/08
DOS 4.00 PS/2 MOD 30 WITH 8512 GET ERROR SELECTING COLOR CHANGE
PROGRAM FROM SHELL MAIN MENU
Reported Symptom IN INCORROUT Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/08
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
USING THE PS/2 MOD 30 WITH AN 8512 ATTACHED, AN ERROR OCCURS
WHEN SELECTING THE COLOR CHANGE PROGRAM FROM THE SHELL MAIN
MENU. THE ERROR READS SHELL FUNCTION NOT ACTIVE AND WHEN HELP
IS SELECTED THE TEXT READS OPTION NOT SPECIFIED IN THE DOSSHELL
.BAT FILE. THE TEXT STATES TO ADD THE NECESSARY OPTION TO THE
BAT ILE. THE /COLOR OPTION IS ALREADY IN THE BAT FILE.
LOCAL FIX:
PROBLEM SUMMARY: ON THE PS/2 MOD 25 AND MOD 30 THE DOS 4.0
SHELL DEFAULTS TO GRAPHICS MODE ON THE COLOR DISPLAYS SO THAT
GRAPHICS AND THE SCROLL BAR CAN BE USED. ON THESE MODELS,
GRAPHICS MODE PUTS THE COLOR DISPLAY IN BLACK/WHITE.
PROBLEM CONCLUSION: TO USE COLOR IN THIS SITUATION, ADD THE
STARTUP OPTION /TEXT IN THE DOSSHELL.BAT FILE. HELP HAS
BEEN ADDED TO INDICATE THIS. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: SHELLHLP SHELLMEU
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79460 Last Changed ........ 88/09/08
DOS 4.00 UPREDICTABLE RESULTS WHEN USING DMA TO NON-CONTIGUOUS
EMS PAGES
Reported Symptom UN UNPRED Status ........... CLOSED PER
Severity ................... 3 Date Closed ......... 88/08/08
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............ 999
Component Name DOS OP SYS Special Activity ....
PE PTF List:
PTF List: UR22624 For Rel: 400 Avail: 88/09/08 (1301 )
ERROR DESCRIPTION:
APPLICATION USING DMA TO EMS PAGES HAS UNPREDICTABLE RESULTS
OCCURRING.
LOCAL FIX:
PROBLEM SUMMARY: APPLICATION USES DMA TO EMS PAGES. THE DMA
REQUEST CROSSES 16KB BOUNDARY AND THE EMS PAGES ARE NOT
CONTIGUOUS. IN THIS SITUATION THE APPLICATION WILL LOSE DATA
AND CAN CAUSE UPREDICTABLE RESULTS.
PROBLEM CONCLUSION: THIS SITUATION IS A RESTRICTION IN DOS 4.00.
TO LESSEN THE OCCURENCE OF THE PROBLEM, THE LINKED LIST FOR
EMS PAGES WAS CHANGED TO AN ASCENDING LINKED LIST, INSTEAD OF A
DESCENDING LINKED LIST. PTF UR22624
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: EMSINIT
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
========================================================================
Apar Identifier ...... IR79306 Last Changed ........ 88/08/03
INT 19H DOES NOT REBOOT CORRECTLY
Reported Symptom IN INCORR Status ........... OPEN
Severity ................... 3 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
DOS 4.00 - INT 19H DOES NOT REBOOT SYSTEM. AFTER SELECTING
DRIVE AND RESETTING THE PRINTER, THE SYSTEM STOPS WITH NO DRIVE
INDICATORS ON AND ONLY A CURSOR ON THE SCREEN. NO COMMANDS CAN
BE ENTERED, HOWEVER CTRL-ALT-DEL DOES FUNCTION. MACHINE TYPE IS
PS/2 MOD 80. IT WORKS CORRECTLY UNDER DOS 3.30.
LOCAL FIX:
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: USA.PRT
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
MESSAGE TO SUBMITTER:
------------------------------------------------------------------------
Apar Identifier ...... IR79568 Last Changed ........ 88/08/17
DOCUMENTATION DISCREPANCIES IN DOS 4.00 COMMAND REFERENCE
Reported Symptom DD DOC Status ........... OPEN
Severity ................... 4 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
THE FOLLOWING ARE DOCUMENTATION DISCREPANCIES/ERRORS FOUND IN
THE DOS 4.00 COMMAND REFERENCE:
PG1...SUMMARY OF CHANGES: STATES 5 NEW COMMANDS, ACTUALLY 6.
PG36..RESET MODE (RM): ESC(=L AND ESC(=0L: IS THE L AN I OR AN
L. (LOWER CASE L IS DIFFICULT TO DISTINGUISH FROM A 1)
PG42..BOTTOM OF PAGE (LAST SYNTAX DIAGRAM): INDICATES THAT THE
SEMI-COLON IS OPTIONAL TO CANCEL PATH - IT IS NOT.
PG52..EXAMPLE 3 S SECOND EXAMPLE: ACCORDING TO SYNTAX DIAGRAM,
THIS IS INCORRECT.
PG53..BACKUP SYNTAX DIAGRAM STATES FILENAME IS REQUIRED. THIS
CONFLICTS WITH THE EXAMPLES ON PG56&57 WHICH HAVE NO
FILENAME.
PG109.DISKCOMP, UNDER PARAMETER /8: ..CONTAINS 9 OR 15 SECTORS
SHOULD READ ..CONTAINS 9, 15 OR 18 SECTORS
PG121.DISPLAY.SYS, ADAPTER TABLE: UNDER IBM PERSONAL SYSTEM/2
THERE IS NO MOD 70 INCLUDED.
PG91..COUNTRY, PARAMETER MMM: THERE IS NO LISTING OF SIMILAR
COUNTRIES DATE/TIME FORMATS TO SELECT A SIMILAR COUNTRY,
AS IT RECOMMEND YOU DO IF YOUR COUNTRY ISN T LISTED.
PG147.FORMAT, PARAMETER /B: ...9 OR 15 SECTORS.. SHOULD READ
...9, 15 OR 18 SECTORS...
PG150.FORMAT, THIRD BULLET: ..COMMAND REQUIRES A VOLUME LABEL
SHOULD READ ..COMMAND REQUESTS A VOLUME LABEL.
PG154.FORMAT, EXAMPLE 3 & 4: INDICATES YOU ARE FORMATTING THE
HARD DISK FROM THE SAME DRIVE (C:).
PG156.GOTO, PARAMETER LABEL: A LABEL IS NOT CASE SENSITIVE.
PG194.MKDIR, REMARKS FOURTH BULLET: USER IS LIMITED TO THE
NUMBER OF ROOT DIRECTORIES.
PG250.RESTORE, 2ND EXAMPLE: ONLY RESTORES THE FILES IN THE
THE CURRENT DIRECTORY.
PG251.RESTORE, LAST TWO EXAMPLES: /A:2:14:89 SHOULD READ
/A:2-14-89
PG255.SET, THIRD BULLET: INSTRUCTIONS ARE VERY CONFUSING AS TO
WHEN AND HOW THE ENVIRONMENT CAN BE CHANGED IN SIZE.
PG273.SYS, SECOND EXAMPLE: THIS IS TECHNICALLY POSSIBLE BUT
TAKES SPECIAL TOOLS TO GET THE HIDDEN SYSTEM FILES TO
A SUBDIRECTORY.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79594 Last Changed ........ 88/08/30
CANNOT SEE CURSOR ON 3270/PC AT DATA ENTRY SCREENS IN SHELL
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 3 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
PANELS IN THE DOSSHELL THAT REQUIRE DATA ENTRY WHEN USING A
3270/PC AT HAVE A WHITE BACKGROUND. THE CURSOR IS ALSO
WHITE. IN ORDER TO FIND THE CURSOR, YOU MUST PLACE THE
KEYBOARD IN INSERT MODE. ALL FOUR DOSSHELL COLOR COMBINATIONS
HAVE THE SAME PROBLEM.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79596 Last Changed ........ 88/08/30
COPY /A /B OPTIONS NOT FUNCTIONING PROPERLY
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 4 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
THE COMMAND COPY M*.P /A M*.NEW /B SHOULD PRODUCE SEVERAL
.NEW FILES WITH NO CTRL-Z (EOF) CHARACTER. WHEN EXECUTED,
THE FIRST .NEW FILE DOES NOT CONTAIN A CTRL-Z, AS DESIRED,
BUT ALL SUBSEQUENT .NEW FILES CONTAIN A CTRL-Z EOF
CHARACTER.
DOS 3.3 PRODUCES THE SAME RESULTS.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79609 Last Changed ........ 88/08/30
FORMAT S VOLUME-ID ENTRY IS NOT WORKING PROPERLY ON 3270PC
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 3 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
WHEN USING DOSSHELL AND CHOOSING DOS UTILITIES TO FORMAT A 3.5
DISKETTE ON A 3270PC, AFTER THE FORMAT IS COMPLETE THE SCREEN
PROMPTS FOR A VOLUME ID OR ENTER. WHEN EITHER ENTERING A NAME
OR ENTERING, THE MESSAGE INVALID ID, RE-ENTER, IS DISPLAYED.
A CONTROL-BREAK IS REQUIRED TO GET OUT OF THIS. THE DISKETTE
IS FORMATTED BUT USER IS UNABLE TO GIVE IT A VOLUME ID. THE
STANDARD FORMAT A: FROM THE DOS PROMPT ALSO GIVES THE SAME
ERROR.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79699 Last Changed ........ 88/08/30
FASTOPEN & BUSINESS ADVISER RENAME/RESTORE
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 3 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
DOS 4.00 FASTOPEN MODE, USER TRIES TO EXECUTE A RESTORE IN
BUSINESS ADVISER AFTER RENAMING A FILE AND IT DOES NOT FUNCTION
CORRECTLY.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79700 Last Changed ........ 88/08/30
INT 21H AH=0B RETURNS INCORRECT STATUS UNDER SHELL
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 2 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
INT 21 AH=0B DOES NOT RETURN KEYBOARD STATUS CORRECTLY WHEN IN A
PROGRAM EXECUTED UNDER THE SHELL AS IT ALWAYS RETURNS ZEROS.
WHEN EXECUTED FROM THE COMMAND LINE IT FUNCTIONS CORRECTLY.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79728 Last Changed ........ 88/08/31
DATE DOES NOT CHANGE AT MIDNIGHT
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 2 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
WHEN USING DOS 4.00 ALONG WITH PC LAN, THE DATE IS NOT
INCREMENTED AT MIDNIGHT.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79733 Last Changed ........ 88/08/31
CHKDSK INDICATES ALLOCATION ERRORS WITH CREATION OF 32MEG FILE
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 2 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
AFTER THE CREATION OF 32MEG FILES, EXACTLY TO THE BYTE, CHKDSK
INDICATES ALLOCATION ERRORS. CHKDSK ALSO APPEARS TO REFLECT
A SMALLER FILE SIZE THAN THE FILE ACTUALLY IS.
SAMPLE ASSEMBLER CODE, WHICH DEMONSTRATES THE ABOVE PROBLEM, IS
BEING MAILED TO THE DOSSUPP ADDRESS.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79747 Last Changed ........ 88/09/07
CSD UR22624 DOCUMENTATION UNCLEAR
Reported Symptom DD DOC Status ........... OPEN
Severity ................... 4 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
DOCUMENTATION IN CSD UR22624 IS UNCLEAR:
IT DOES NOT STATE THAT YOU MUST INSERT DISKETTE #1 IN DRIVE A
AND RE-IPL.
IT IS NOT CLEAR THAT IR79459 MUST BE SEPARATELY INSTALLED.
THE SHELL.MEU FILE SHOULD NOT BE RENAMED AS THERE MUST BE A FILE
SHELL.MEU TO BE REPLACED.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79754 Last Changed ........ 88/09/07
APPEND /X:ON NOT WORKING PROPERLY WITH DIR COMMAND
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 3 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
APPEND /X:ON DOES NOT WORK PROPERLY WITH DIR COMMAND AS FOLLOWS:
APPEND C:-DOS <ENTER> (THE DASH REPRESENTS A BACKSLASH)
DIR A: <ENTER> (DRIVE A: S DIRECTORY IS DISPLAYED)
APPEND /X:ON <ENTER>
DIR A: <ENTER> (DRIVE C: S DIRECTORY IS DISPLAYED)
APPEND /X:OFF <ENTER>
DIR A: <ENTER> (DRIVE A: S DIRECTORY IS DISPLAYED)
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79756 Last Changed ........ 88/09/07
UNABLE TO READ OUT BEYOND ABOUT 500MB OF A 600MB FILE
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 3 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
WHEN WORKING WITH FILES OF 600MB IN SIZE, DOS IS UNABLE TO
ACCESS (READ OUT) BEYOND ABOUT 500MB OF THE FILE (BEYOND 64K
SECTORS). THE CALL TO THE CD ROM OPTICAL DISK DRIVER EITHER
NEVER OCCURS AND DOS RETURNS CARRY CLEAR OR COMPLAINS OF
A BAD FAT AND THEN RETURNS.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79791 Last Changed ........ 88/09/08
UNABLE TO USE SELECT ON MOD 80 THAT HAS BEEN LOW LEVEL FORMATTED
Reported Symptom IN INCORROUT Status ........... OPEN
Severity ................... 2 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
CUSTOMER INSTALLS DOS 4.00 ON A BRAND NEW MODEL 80 WITH A 44 MEG
HARDFILE, AFTER THE MACHINE HAS BEEN LOW LEVEL FORMATTED. THE
MACHINE IS FDISKED DURING THE SELECT PROCESS TO 1 (44 MEG)
PARTITION. ALL DEFAULTS ARE USED IN THE SELECT PROCEDURE.
WHEN IT IS COMPLETE, THE DISKETTES ARE REMOVED AND THE MACHINE
IS CTRL-ALT-DELETED. THE MACHINE DOES THE MEMORY COUNT AND THEN
HAS A BLANK SCREEN. THE CUSTOMER THEN HAD TO SYS THE C: DRIVE
FROM THE INSTALL DISKETTE IN ORDER TO BRING UP DOS 4.00 ON THE
MODEL 80.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79805 Last Changed ........ 88/09/08
DOS 4.00 NOT WORKING PROPERLY WITH PC LAN 1.3 REFERENCE PTF5184
Reported Symptom IN INCORROUT Status ........... INTRAN
Severity ................... 1 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
TWO REMOTE WORKSTATIONS BOOT OFF A DISKETTE THAT CONTAINS THEIR
AUTOEXEC.BAT THAT CONTAINS THEIR NETWORK START UP AND USE
COMMANDS. THEY LOGON TO THE SRV S DRIVE, EXECUTE THE BUSINESS
ADVISOR PROGRAM (ADV.EXE) WHICH WILL BRING UP A MENU. THE FIRST
TERMINAL CAN ACCESS THE PROGRAM FINE, BUT WHEN THE SECOND
TERMINAL TRIES TO ACCESS IT, THE SYSTEM IS LOCKED UP AFTER
TRYING TO EXECUTE BUSINESS ADVISOR. CUSTOMER WAS GIVEN UPDATED
RELEASE THAT FIXED PART OF THE PROBLEM. INSTEAD OF THE SECOND
SYSTEM HANGING, IT NOW IS GIVING AN ERROR MESSAGE: SHARING
VIOLATION CODE - 12 AND CLASS/ACTION/LOCUS CODE - 000 (WHICH
IS INVALID). THE ERROR CONDITION WAS BELIEVED TO BE THAT MODULE
IFS.EXE WAS DOING INFINITE RETRYS INSTEAD OF GIVING AN ERROR
CONDITION. DOS DEVELOPMENT HAS BEEN CONTACTED AND HAS CREATED
PTF 5184 IN REFERENCE TO THIS PROBLEM.
LOCAL FIX:
------------------------------------------------------------------------
Apar Identifier ...... IR79811 Last Changed ........ 88/09/08
PROBLEM WITH BACKUP COMMAND WITH PC LAN 1.3 REFERENCE PTF5185
Reported Symptom IN INCORROUT Status ........... INTRAN
Severity ................... 3 Date Closed .........
Component .......... 560119301 Duplicate of .........
Reported Release ......... 400 Fixed Release ............
Component Name DOS OP SYS Special Activity ....
PE PTF List:
ERROR DESCRIPTION:
THEY ARE USING THE IBM BUSINESS ADVISOR PROGRAM AND WITHIN ARE
TRYING TO EXECUTE THE BACKUP COMMAND, WHICH IS FOUND E:-DOS-
BACKUP.COM, ALL OF WHICH INFORMATION IS INDICATED WHEN
PERFORMING THE BACKUP COMMAND THAT IS MENU DRIVEN. THE ERROR
MESSAGE, CANNOT FIND FOMAT.COM IS GIVEN. NO PATH IS LISTED
ON EITHER MACHINE, THE SERVER OR THE WORKSTATION. THE
WORKSTATION IS LOGGED ONTO THE SERVER S DRIVE. THE PROBLEM CAN
BE RECREATED IN A STANDALONE CONFIG. DOS DEVELOPMENT HAS BEEN
CONTACTED AND PTF 5185 HAS BEEN CREATED FOR THIS PROBLEM.
LOCAL FIX:
------------------------------------------------------------------------