  1.  
  2.                           FIELD BULLETIN NUMBER 21
  3.                                 July 1983
  4.  
  5.                         TS 803: CHANGING BAUD RATE
  6.  
  7.         Baud rates for the serial printer port and  the  modem  port  are
  8.         controlled through the timer data registers of the Z80 STI.   The
  9.         modem port is set with timer A of the STI at address  %2A.    The
  10.         serial printer is on timer B at address %2B.   To change the baud
  11.         rates for either of these channels,  write the  hexadecimal  byte
  12.         corresponding  to  the  required  baud  rate into the appropriate
  13.         timer data register:
  14.  
  15.         Hex Byte           Decimal (ref)            Baud Rate
  16.           01                     01                  9600
  17.           02                     02                  4800
  18.           04                     04                  2400
  19.           08                     08                  1200
  20.           10                     16                   600
  21.           20                     32                   300
  22.           40                     64                   150
  23.           60                     96                   110
  24.           80                    128                    75
  25.  
  26.         Baud rates for the keyboard,  mouse,  and TS 803 option board are
  27.         fixed.
  28.  
  29.                       TS 816/40: TRANSFER I/O PROBLEMS
  30.  
  31.         Transfer  I/O  problems  are  occuring  on some TS 816/40 systems
  32.         When this occurs,  install jumpers on the  main  logic  board  as
  33.         listed below.   Transfer problems are associated with a TS 816/40
  34.         transfer out and a user station transfer in.   An XFO error  mes-
  35.         sage  will display on the service terminal with identification of
  36.         the associated user station.   This fix is only for those systems
  37.         that have persistent problems, and should not be performed on un-
  38.         affected  systems.    This  is a detailed modification and should
  39.         only be installed by  qualified technicians using  proper  equip-
  40.         ment.   Be especially careful of static electricity damage to the
  41.         logic board.   PERFORM THIS MODIFICATION ONLY IF THERE  ARE  PER-
  42.         SISTENT XFO ERRORS ASSOCIATED WITH THE SYSTEM.
  43.  
  44.         Device                Jumper
  45.         A23                  Pin 31 to pins 18 and 23
  46.         A24                  Pin 31 to pins 18 and 23
  47.         A36                  Pin 31 to pins 18 and 23
  48.         A37                  Pin 31 to pins 18 and 23
  49.         A66                  Pin 31 to pins 18 and 23
  50.         A67                  Pin 31 to pins 18 and 23
  51.         A81                  Pin 31 to pins 18 and 23