home *** CD-ROM | disk | FTP | other *** search
- 0 Null XYSee 3.0 Demonstration MACRO... 0sineTest.MAC 5/91.
- 0 Null (c) 1991, Insight Advantage. All Rights Reserved.
- 0 BEEP
- 0 MESSAGE
- Example of using XYSee for :
- 3 MESSAGE
- ** TESTING **
- 1 MESSAGE {Blank out line}
-
- 1 MESSAGE
- ** TESTING **
- 1 MESSAGE {Blank out line}
-
- 1 MESSAGE
- Your requirements may be more sophisticated,
- 4 MESSAGE
- but don't worry...
- 3 MESSAGE
- XYSee MACROs are SIMPLE to prepare !
- 4 MESSAGE
- You may print a copy of this testing routine...
- 4 MESSAGE
- with the Editor. The Macro name is "0SINTEST"
- 4 MESSAGE
- Locking the Keyboard...Click !
- 2 OFF-KEY
- 0 MESSAGE {Blank out line}
-
- 0 ACCEPT Select the FAMILY Menu.
- 0 DOWN
- 1 DOWN
- 1 ACCEPT Select the TRIGONOMETRIC Menu.
- 1 ACCEPT Select the SINE module.
- 0 MESSAGE
- First let's set some initial conditions.
- 4 UP
- 1 UP
- 0 MESSAGE
- We'll set the model to Y=Asin(BX+C).
- 4 ACCEPT Select the Select Model option.
- 0 ENTRY Selected model is Y=Asin(BX+C)
- 4
- 1 ACCEPT Select the VARIABLE UPDATE Menu.
- 0 MESSAGE
- And initialize our variables.
- 4 DOWN Enter an initial set of values.
- 1 ACCEPT "A"
- 1 8.0 Enter values for the variables...
- 1 DOWN
- 1 DOWN
- 1 ACCEPT "B"
- 1 1.0
- 1 UP
- 1 ACCEPT "C"
- 1 0.0
- 0 MESSAGE {Blank out line}
-
- 1 CANCEL To plot the initial values.
- 1 DOWN
- 1 DOWN
- 1 ACCEPT Select the OVERLAY Menu.
- 0 MESSAGE
- Let's STORE the initial conditions.
- 4 ACCEPT STORE the initial plot.
- 0 MESSAGE {Blank out line}
-
- 1 DOWN
- 0 BEEP Time to start...
- 1 ACCEPT Select the CURSOR option.
- 0 MESSAGE
- == Ready? ... Let's Begin ==
- 4 RIGHT * 15 Move to the Minimum Amplitude point.
- 0 DOWN * 2
- 0 MESSAGE MINIMUM AMPLITUDE
- What is this point on a wave called?
- 9 LEFT * 6 Move to the Maximum Amplitude point.
- 0 UP * 33
- 0 MESSAGE MAXIMUM AMPLITUDE
- What is this point on a wave called?
- 9 MESSAGE
- The magnitude from this point...
- 5 DOWN * 66
- 0 RIGHT * 13
- 0 MESSAGE PEAK-TO-PEAK AMPLITUDE
- To the opposite point is called?
- 9 CANCEL Exit the CURSOR option.
- 0 MESSAGE {Blank out line}
-
- 1 ACCEPT Select the VARIABLE UPDATE Menu.
- 1 UP
- 1 ACCEPT "C"
- 1 -1.5
- 1 CANCEL Replot with the new values.
- 1 DOWN
- 1 ACCEPT Select the CURSOR option.
- 0 LEFT * 7
- 0 UP * 66
- 0 MESSAGE
- What is the distance from this point on the wave...
- 5 LEFT * 26 Position the cursor to the second point/wave.
- 0 MESSAGE WAVELENGTH
- To this point on the wave called?
- 9 CANCEL Exit the CURSOR option.
- 0 MESSAGE PERIOD
- What is the time duration for a single cycle?
- 9 MESSAGE FREQUENCY
- The number of cycles in one second is called?
- 7 MESSAGE HERTZ
- It's unit of measurement is the?
- 7 MESSAGE {Blank out line}
-
- 0 DOWN
- 1 DOWN
- 1 ACCEPT Select the OVERLAY option.
- 1 DOWN
- 1 ACCEPT RESTORE our previous plot.
- 1 DOWN
- 1 ACCEPT Select the CURSOR option.
- 0 MESSAGE
- What is the difference from this point...
- 5 LEFT * 7
- 0 MESSAGE PHASE SHIFT
- To the same point on a different wave called?
- 9 MESSAGE {Blank out line}
-
- 0 CANCEL Exit the CURSOR option.
- 1 ACCEPT Select the VARIABLE UPDATE Menu.
- 1 DOWN
- 1 ACCEPT "A"
- 1 5.0 Amplitude value first.
- 1 UP
- 1 ACCEPT "C"
- 1 0.0 Followed by the Phase Shift. (none here)
- 1 CANCEL Replot with the new values.
- 1 DOWN
- 1 DOWN
- 1 ACCEPT Select the OVERLAY option.
- 1 DOWN
- 1 ACCEPT RESTORE the initial plot again.
- 1 DOWN
- 1 ACCEPT Select the CURSOR option.
- 0 MESSAGE
- What is the variation from this point...
- 5 DOWN * 12
- 0 MESSAGE AMPLITUDE DIFFERENCE
- To the matching point called?
- 9 MESSAGE {Blank out line}
-
- 0 CANCEL Exit the CURSOR option.
- 1 ACCEPT Select the VARIABLE UPDATE Menu.
- 1 DOWN
- 1 ACCEPT "A"
- 1 8.0 Enter an additional set of values.
- 1 DOWN
- 1 DOWN
- 1 ACCEPT "B"
- 1 2.0
- 1 CANCEL Replot with the new values.
- 1 DOWN
- 1 DOWN
- 1 ACCEPT Select the OVERLAY option.
- 1 DOWN
- 1 ACCEPT RESTORE once again.
- 1 DOWN
- 1 ACCEPT Select the CURSOR option.
- 0 UP * 12
- 0 MESSAGE
- What is the Frequency Ratio of this wave...
- 5 RIGHT * 10 Reposition the cursor.
- 0 MESSAGE FREQUENCY RATIO
- To this other wave on the display?
- 9 CANCEL Exit the CURSOR option.
- 0 MESSAGE FUNDAMENTAL
- What is the term given to...
- 5 MESSAGE
- the lowest frequency wave?
- 7 MESSAGE HARMONIC
- What is the term given to...
- 5 MESSAGE
- the higher frequency wave?
- 7 MESSAGE {Blank out line}
-
- 0 ACCEPT Select the VARIABLE UPDATE Menu.
- 1 DOWN
- 1 ACCEPT "A"
- 1 -8.0 Enter the final set of values.
- 1 DOWN
- 1 DOWN
- 1 ACCEPT "B"
- 1 1.0
- 1 CANCEL Replot with the new values.
- 1 DOWN
- 1 DOWN
- 1 ACCEPT Select the OVERLAY option.
- 1 DOWN
- 1 ACCEPT Restore the last time.
- 1 MESSAGE OUT OF PHASE
- Are these waves IN or OUT of phase?
- 7 MESSAGE {Blank out line}
-
- 0 CANCEL Exit the SINE module.
- 1 CANCEL Exit the TRIGONOMETRIC Menu.
- 1 CANCEL To the MAIN Menu.
- 0 MESSAGE
- Unlocking the Keyboard...Click !
- 2 ON-KEY
- 0 MESSAGE
- It's time to check your answers.
- 4 MESSAGE
- While we're covering the answers, you may...
- 4 MESSAGE
- Press <ACCEPT> to allow time to...
- 4 MESSAGE
- correct your sheet.
- 2 MESSAGE
- Ready to start?
- 0 WAIT Until ready...
- 0 MESSAGE
- The first question was an easy warmup,
- 4 MESSAGE
- It is the MINIMUM AMPLITUDE.
- 6 MESSAGE
- Another easy one, recognize the...
- 6 MESSAGE
- MAXIMUM AMPLITUDE point?
- 6 MESSAGE
- The third one was a little harder...
- 6 MESSAGE
- It's PEAK to PEAK.
- 6 MESSAGE
- I hope you remembered the...WAVE LENGTH.
- 6 MESSAGE
- Number five is the...PERIOD.
- 6 MESSAGE
- A couple of basic ones...FREQUENCY and...
- 6 MESSAGE
- It's unit of measurement...HERTZ or Hz.
- 6 MESSAGE
- Number eight was harder...PHASE SHIFT.
- 6 MESSAGE
- The variation here is in the...AMPLITUDE.
- 6 MESSAGE
- I hope you looked closely, the ratio was 1:2.
- 6 MESSAGE
- The lowest frequency is the...FUNDAMENTAL.
- 6 MESSAGE
- Multiples of the fundamental are...HARMONICS.
- 6 MESSAGE
- Another easy one, the waves are OUT of PHASE.
- 6 MESSAGE
- We've covered a lot, I hope you did well !
- 4 MESSAGE
- Please retain your answer sheet for review.
- 4 BEEP Notify the Instructor.
- 0 BEEP Once again for good measure.
- 0 STOP Terminate this testing MACRO.