  1.  
  2.                         ScanTek 3.3
  3.  
  4.                     A scanner driver for
  5.                Microtek, Highscreen and Mustek
  6.                       Flatbed Scanner
  7.  
  8.  
  9.             ⌐ Copyright 1995/96/97 Waldemar Z÷hner
  10.  
  11.                   Get It, Feel It, Love It
  12.  
  13.  
  14.  Overview
  15. ----------
  16.  
  17.  The ScanTek scanner driver has the following features:
  18.  
  19.  1. Support of the following SCSI Microtek scanner models:
  20.         MICROTEK IISP, MICROTEK II, HIGHSCREEN Flatbed Color IIs,
  21.         ScanMaker E3, ScanMaker 35t, ScanMaker E6,
  22.         Highscreen PerfectScan, Highscreen HighScan
  23.  
  24.     Support of the following SCSI Mustek scanner models:
  25.         Three Pass Scanners:
  26.         6000CX, 8000CX (not tested), 12000CX (not tested) all should work
  27.  
  28.         One or Single Pass Scanners:
  29.         6000SP, 8000SP (not tested), 12000SP (not tested) all should work
  30.         6000CZ (not tested), 8000CZ (not tested)
  31.  
  32.         600IISP, 800IISP (not tested) all should work
  33.  
  34.     If your scanner is not mentioned in the list above try it and
  35.     give me a response whether it works or not.
  36.  
  37.     Attention: In recent times Mustek has changed the scanner firmware.
  38.                I urge you to test Mustek scanners with your Amiga
  39.                configuration before buying it.
  40.  
  41.                Mustek scanners have a critical SCSI interface. It
  42.                was reported to me that these scanners may not work
  43.                with the A3000(T) internal SCSI interface. It is
  44.                possible that these scanners do not work with other
  45.                SCSI host adapters, either.
  46.                But the Mustek 6000CX works in combination with an
  47.                Oktagon SCSI host adapter.
  48.                Be sure to disable reselection for Mustek scanners
  49.                on your SCSI host adapter. Otherwise your system may
  50.                not boot.
  51.  
  52.  
  53.  2. Support of black/white, built-in halftone (dither), one-pass-color-scan,
  54.     three pass color scan, grey, red, green and blue scan.
  55.  
  56.  3. Individual setting of resolution, scanning frame, contrast, shadow,
  57.     midtone, highlight, exposure time and scanning speed for download to the
  58.     scanner.
  59.  
  60.  4. Download of a color look up table (gamma correction table ) to the scanner
  61.     supported.
  62.  
  63.  5. Scanning to IFF File of 1, 8 or 24 bit color depth. The maximum size of
  64.     the scanned image is independent from the RAM size. After the scanning
  65.     process it is possible to start an external program.
  66.  
  67.  6. GUI for preview and configuration of the driver. You need Kickstart 2.04
  68.     but Kickstart 3.0 is recommended.
  69.  
  70.  7. Sizeable preview window in black/white or grey scale. Color preview
  71.     on Cybergraphix screens (15, 16 or 24 bit necessary).
  72.     There are much more skilled programs to view and manipulate the scanned
  73.     images in color. (A tool like ADPRO, IMAGE FX or so is needed, if you
  74.     want to do sophisticated postproduction)
  75.  
  76.  8. ARexx support
  77.  
  78.  9. Screenmode requester to define custom screen for working. The actual public
  79.     screen is supported as well
  80.  
  81.  10. Configurable SCSI device and SCSI ID. The driver supports only SCSI
  82.      connectable scanners.
  83.  
  84.  11. The driver is tested with the following SCSI drivers: oktagon.device and
  85.      gvpscsi.device V4.5.
  86.  
  87.  12. ScanTek is written using SAS C 6.55.
  88.  
  89.  13. ScanTek is SHAREWARE.
  90.  
  91.  14. The non registered version of ScanTek is a full working version, but all
  92.      scanned images have black lines to motivate you to register.
  93.      Additionally the maximum size of the preview is restricted.
  94.  
  95.  
  96.  History
  97. ---------
  98.  
  99.  V3.3  1 August 1997
  100.  
  101.    - Detection of ScanMaker35t+ introduced 
  102.    - Faster preview scanning process on some scanner models
  103.    - "Accurate Coordinates" support for ScanMaker E6 and compatible
  104.  
  105.  
  106.  V3.2   8 June 1997
  107.  
  108.    - Workaround for surfsquirrel.device to avoid SCSI bus hangup
  109.    - AREXX scripts: Load scanned pictures into 
  110.                     ImageFX:   ST2ImageFX.strx
  111.                     ArtEffect: ST2ArtEffect.strx
  112.  
  113.  
  114.  V3.1  19 May 1997
  115.  
  116.    - Recognition of Highscreen PerfectScan (600dpi) introduced
  117.    - Recognition of Highscreen RealScan (300dpi) introduced
  118.    - Activation of newly opened windows works now correct
  119.  
  120.  
  121.  V3.0   16 Apr. 1997
  122.  
  123.    - AREXX support
  124.    - XBMI-chunk introduced to store DPI (dots per inch) information in
  125.      IFF File
  126.    - Handling of Microtek ScanMaker E6 enhanced
  127.    - Bugfixes: "Exposure Time" and "Contrast" parameters for Microtek
  128.                and some Mustek scanner models are now correct.
  129.                This bug could lead to images that where to light.
  130.                Grey preview of color image now work with all specified
  131.                settings.
  132.  
  133.  
  134.  V2.10 26 Mar. 1997
  135.  
  136.    - Full size preview on 400 dpi Mustek scanners adjustable
  137.  
  138.  
  139.  V2.9   9 Feb. 1997
  140.  
  141.    - Look Up Table Window redesigned to ensure font sensitivity
  142.  
  143.  
  144.  V2.8  11 Jan. 1997
  145.  
  146.    - New icons for ScanTek
  147.    - Recognition and handling of new Mustek scanners enhanced
  148.    - Minior bug fixes
  149.    - Introduction of the ScanTek Support WebSite
  150.  
  151.  
  152.  V2.7  6 Dec. 1996
  153.  
  154.    - Recognition and handling of new Mustek scanners enhanced
  155.    - Recognition of Microtek ScanMaker E6 adapted
  156.  
  157.  
  158.  V2.6  30 Oct. 1996
  159.  
  160.    - Full support of Mustek one pass scanners
  161.    - Recognition of Mustek scanners enhanced
  162.  
  163.  
  164.  V2.5  5 Oct. 1996
  165.  
  166.    - Workaround to handle strange color mode behaviour of Mustek
  167.      one pass scanners
  168.    - Reverse scanning in black and white mode introduced
  169.  
  170.  
  171.  V2.4 10 Sept. 1996
  172.  
  173.    - Support of Mustek SCSI one pass color scanners in color mode and
  174.      parameter ranges.
  175.    - ScanTek can now open its GUI windows on the actual public screen.
  176.  
  177.  
  178.  V2.3  6 Sept. 1996
  179.  
  180.    - Color Preview on Cybergraphix screens in true color mode
  181.      (15, 16 or 24 bit) for onepass flatbed scanners
  182.    - Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
  183.      (15, 16 or 24 bit) for threepass and onepass flatbed scanners
  184.    - Change and recall of predefined resolution values
  185.  
  186.  
  187.  V2.2 26 July 1996
  188.  
  189.    - Enhanced support for Mustek scanners
  190.      "Exposure Time" and "Contrast" parameters are now correct
  191.    - Gamma value "All" now works on threepass scanner
  192.    - Alternative Black/White scanning mode
  193.  
  194.  
  195.  V2.1  5 July 1996
  196.  
  197.    - Preview now fully supported for Mustek 6000CX
  198.    - Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame
  199.  
  200.  
  201.  V2.0  30 Apr. 1996
  202.  
  203.    - Preview in color mode with proper options values
  204.    - Use of expanded Contrast and Exposure Time selections on certain scanners
  205.    - X and Y Aspect Ratio in color images is correct now
  206.    - ScanMaker E3 does not support undocumentated red, gree and blue scanning
  207.    - Lookup Table command supported (Gamma Correction on certain scanner
  208.      possible)
  209.    - Scanning Frame Setting is now more intuitive
  210.    - Reverse image scanning supported (only on certain scanners possible)
  211.    - Accurate scanning supported. Scanning frame is now more precise.
  212.  
  213.  
  214.  V1.3  25 Feb. 1996
  215.  
  216.    - Detection of new ScanMaker E3 Flatbed scanner implemented
  217.    - Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
  218.      (due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
  219.    - No start of the external program, if the scanning process is aborted
  220.    - Higher dpi rates for ScanMaker 35t (slide scanner) possible
  221.      Preview image should look better now.
  222.    - "Main Control" window and gadgets modified
  223.    - Debug filename "ScanTek.log" can be overriden through CLI or Tooltype
  224.  
  225.  
  226.  V1.2   3 Jan. 1996
  227.  
  228.    - Debug output data revised and enhanced
  229.    - Max Frame Setting setting introduced
  230.    - Start of external program possible
  231.    - Window positions are remembered and saved
  232.    - Configuration file enhanced
  233.  
  234.  
  235.  V1.1  17 Dec. 1995
  236.  
  237.    - detection of Microtek scanner via SCSI inquiry enhanced
  238.    - stepping of resolution slider adapted to expanded base resolution
  239.    - calculation of scanning frame size data modified
  240.  
  241.  
  242.  V1.0  30 Nov. 1995
  243.  