home *** CD-ROM | disk | FTP | other *** search
/ MacAdvocate 2 / apple-mac-advocate-ii-fall-1997.iso / mac / MacOS / Helpful Hints and FAQs / Apple Tech Info Library / Energy Saving Cntrl Pnls Desc < prev    next >
Encoding:
Text File  |  1996-12-02  |  13.1 KB  |  198 lines  |  [TEXT/ttxt]

  1. Revised:       11/12/96
  2. Security:      Everyone
  3.  
  4. Energy Saving Control Panels: Description & Compatibility 10/96
  5.  
  6. ======================================================================
  7.  
  8. Article Created: 10 July 1995
  9. Article Reviewed/Updated: 1 October 1996
  10.  
  11. TOPIC -----------------------------------------------------------
  12.  
  13. What is the difference between all the different energy-saving control panels, and how do I know when to use them?
  14.  
  15. DISCUSSION ------------------------------------------------------
  16.  
  17. Energy Related Control Panels Overview
  18. ======================================
  19.  
  20. There are four different energy-related control panels in System 7.5.
  21.  
  22. • Auto Power On/Off: Turns the computer ON and OFF at specified times.
  23.  
  24. • CPU Energy Saver: Turns the computer OFF at specified times, but not ON.
  25.  
  26. • Energy Saver 1.0: Puts an external monitor into energy-saving mode.
  27.  
  28. • Screen: Puts an internal monitor into energy-saving mode.
  29.  
  30. • Energy Saver 2.0: Combines functionality of CPU Energy Saver, Energy Saver 1.0, and Auto Power On/Off. Energy Saver 2.0 is compatible only on PCI-based Power Macintosh computers, which includes the Power Macintosh 5400, 6400, 7200, 7500, 7600, 8500, and 9500 series computers.
  31.  
  32.  
  33. These control panels only work on certain Macintosh computers. In addition, the Energy Saver 1.0 control panel requires an Energy Star-compliant monitor as well as a Macintosh computer compatible with this software. See the chart at the end of this article for a list of compatible systems.
  34.  
  35. Although many Energy Saver control panels are compatible with many Macintosh Performa computers, not all Energy Saver control panels are bundled with Macintosh Performa computers. Many Macintosh Performa computers include modems and MegaPhone software, which allow you to use your computer as an answering machine. If you have installed Auto Power On/Off, it is possible for your computer to be inadvertently shut down while your computer is set to answer phone messages. To avoid this, Macintosh Performa computers do not ship with the Auto Power On/Off control panel.
  36.  
  37. None of the energy-related control panels mentioned here are supported on PowerBook or PowerBook Duo products.
  38.  
  39. Auto Power On/Off
  40. -----------------
  41. This feature lets you set your Macintosh computer to power ON and OFF at a pre-determined time, on a daily basis, or for one particular day. It also has a check box labelled "Automatically restart after power failure". If you check this box and the power goes off, the computer automatically restarts. You can use the Auto Power On/Off feature in conjunction with other System 7.5 features. For example, you could set your system to power on at night and run an AppleScript that re-indexes all of your database files or backs up your hard drive.
  42.  
  43. This control panel can only be used on computers that can be turned off by using the Shut Down command (soft power off) and that have the "Cuda" ADB controller chip or a version of the Motorola 68HC05 microcontroller chip. The chart at the end of this article lists the Macintosh models this control panel is compatible with.
  44.  
  45. NOTE: Not included with all system software prior to System 7.5
  46.  
  47. CPU Energy Saver
  48. ----------------
  49. This feature lets you set your Macintosh to turn OFF at a specified time. However, you cannot set your system to turn ON with this feature. It can only be used on computers that can be turned off by using the Shut Down command (soft power off), such as the Quadra 700. This feature is only installed by System 7.5 if Auto Power On/Off is NOT compatible with the Macintosh and CPU Energy Saver IS compatible with the Macintosh.
  50.  
  51. NOTE: This control panel did not ship with system software older than System 7.5, although it was released separately before System 7.5.
  52.  
  53.  
  54. Energy Saver 1.0
  55. ----------------
  56. This feature lets you set your Macintosh to put external monitors into sleep mode. It was originally designed to work with the built-in video of Macintosh LC III, Quadra 610-950, Power Macintosh, and Performa 450-467, 63x, 611x.
  57.  
  58. This feature requires an Energy Star-compliant monitor. Compliant models include:
  59.  
  60. • Apple Color Plus 14-in. Display
  61. • Macintosh Color Display (newer M1198LL/B version)
  62. • Apple AudioVision 14 Display
  63. • Apple Multiple Scan 14, 15, 17, and 20 Displays
  64.  
  65. NOTE:
  66. Not included with system software prior to System 7.5, although it was made available separately.
  67.  
  68. This feature did not come preinstalled on some Performa 630- and 6110-series systems and was not included on the backup CDs that shipped with these systems. Customers who want the Energy Saver software can copy it from the disk that comes with the Multiple Scan 15 Display. (Be sure not to copy the Display Enabler extension, since the Performa 630- and 6110-series systems have the Display Enabler's functionality built into the hardware.)
  69.  
  70. If Energy Saver is installed on a computer that has an incompatible monitor, the monitor goes black after the specified inactivity period has passed, but the incompatible monitor is NOT in low power mode, and therefore is NOT saving energy. Monitors that do not support this Energy Saver function, or monitors that use video cards, are not harmed by the installation of this control panel, but they do not save energy with Energy Saver installed.
  71.  
  72. The Energy Saver control panel has a slider bar to adjust the monitor inactivity period, from 15 to 60 minutes. Energy Saver can be turned on by clicking the check box nearest the slider bar. The settings take effect immediately; you do not need to restart the computer.
  73.  
  74. When the Apple Energy Star-compliant monitor has been inactive (that is, you have not used the mouse or keyboard) for the time specified in the Energy Saver control panel, the screen of the monitor goes black. This indicates that the monitor is in low-power mode, and is saving energy. The computer is still functioning.
  75.  
  76. The monitor returns to a fully active state approximately 20 seconds after you use the keyboard or mouse. You hear a number of beeps while the screen is updated to reflect its current state. (The beep volume cannot be adjusted; it is independent of all system sound controls.)
  77.  
  78. Screen
  79. ------
  80. This control panel lets you set your Macintosh computer to put internal monitors into sleep mode.
  81.  
  82. The Screen control panel can only be used on certain "all-in-one" Macintosh systems, such as the LC/Performa 500-series.
  83.  
  84. This feature shipped with some Performa 630-series systems and appears to work, but does not really save energy. The Screen control panel should be removed from these systems. Use the Energy Saver control panel in its place.
  85.  
  86. Energy Saver 2.0
  87. ----------------
  88. This control panel combines functionality of CPU Energy Saver, Energy Saver 1.0, and Auto Power On/Off. Energy Saver 2.0 is compatible only on PCI-based Power Macintosh computers, which includes the Power Macintosh 5400, 7200, 7500, 7600, 8500, and 9500 series computers.
  89.  
  90. NOTE: Energy Saver 2.0 is available only in System 7.5.2 or later when used on a PCI-based Power Macintosh computer.
  91.  
  92. Begin_Table
  93.  
  94. WHEN TO USE WHICH ENERGY-SAVING CONTROL PANELS
  95. -----------------------------------------------------------------------------
  96.                                       | < FOR MONITORS>  | < FOR COMPUTER>
  97.  YES = preferred                      |                  |
  98.   OK = compatible, but not preferred  |                  | Auto     CPU
  99.   NO = incompatible                   |  Energy          | Power    Energy
  100.                                       |  Saver   Screen  | On/Off   Saver
  101. --------------------------------------+------------------+------------------
  102. COMPACT MACINTOSH SYSTEMS             |                  |
  103.                                       |                  |
  104. Macintosh 128K, 512K, 512Ke, XL       |    NO      NO    |   NO       NO
  105. Macintosh Plus, SE, SE/30             |    NO      NO    |   NO       NO
  106. Classic, Classic II, Performa 200     |    NO      NO    |   NO       NO
  107. Color Classic, Color Classic II       |    NO      YES   |   YES      OK
  108. --------------------------------------+------------------+------------------
  109. MACINTOSH II SYSTEMS                  |                  |
  110.                                       |                  |
  111. Macintosh II, IIx, IIfx               |    YES     NO    |   NO       YES
  112. Macintosh IIcx, IIci                  |    YES     NO    |   NO       YES
  113. Macintosh IIsi, IIvi, IIvx            |    YES     NO    |   YES      OK
  114. --------------------------------------+------------------+------------------
  115. MACINTOSH LC SYSTEMS                  |                  |
  116.                                       |                  |
  117. Macintosh LC, LC II                   |    NO      NO    |   NO       NO
  118. Macintosh LC III, LC 475              |    YES     NO    |   NO       NO
  119. Macintosh LC 520, 550, 575, 580       |    NO      YES   |   YES      OK
  120. Macintosh LC 630                      |    YES     NO    |   YES      OK
  121. --------------------------------------+------------------+------------------
  122. MACINTOSH CENTRIS & QUADRA SYSTEMS    |                  |
  123.                                       |                  |
  124. Macintosh Quadra 605                  |    NO      NO    |   NO       NO
  125. Macintosh Centris/Quadra 610          |    YES     NO    |   NO       NO
  126. Macintosh Quadra 630                  |    YES     NO    |   YES      OK
  127. Macintosh Centris/Quadra 650          |    YES     NO    |   NO       YES
  128. Macintosh Centris/Quadra 660AV        |    YES     NO    |   NO       NO
  129. Macintosh Quadra 700                  |    NO      NO    |   NO       YES Macintosh Quadra 800                  |    YES     NO    |   NO       YES
  130. Macintosh Quadra 840AV, 950           |    YES     NO    |   YES      OK
  131. Macintosh Quadra 900                  |    NO      NO    |   YES      OK
  132. --------------------------------------+------------------+------------------
  133. MACINTOSH PERFORMA SYSTEMS            |                  |
  134.                                       |                  |
  135. Performa 200                          |    NO      NO    |   NO       NO
  136. Performa 250, 275                     |    NO      YES   |   YES      OK
  137. Performa 400, 405, 410, 430           |    NO      NO    |   NO       NO
  138. Performa 450, 460, 466, 467           |    YES     NO    |   NO       NO
  139. Performa 475, 476                     |    YES      NO   |   NO       NO
  140. Performa 520, 550, 560                |    NO      YES   |   YES      OK
  141. Performa 570-, 580-series             |    NO      YES   |   YES      OK
  142. Performa 600                          |    YES     NO    |   YES      OK
  143. Performa 630-, 640-series             |    YES     NO    |   YES      OK
  144. Performa 5200-series                  |    NO      YES   |   YES      OK
  145. Performa 6100-series                  |    YES     NO    |   NO       NO
  146. Performa 6200-series                  |    YES     NO    |   OK*      NO
  147. Performa 6300-series                  |    YES     NO    |   OK       YES
  148. Performa 6400 series                  |    YES•    NO    |   NO•      NO
  149. --------------------------------------+------------------+------------------
  150. POWER MACINTOSH SYSTEMS               |                  |
  151.                                       |                  |
  152. Power Macintosh 5200/75 LC            |    NO      YES   |   YES      OK
  153. Power Macintosh 5260                  |    NO      YES   |   YES      OK
  154. Power Macintosh 5400                  |    YES•    NO    |   NO•      NO
  155. Power Macintosh 6100/60, 6100/66      |    YES     NO    |   NO       NO
  156. Power Macintosh 6200/75               |    YES     NO    |   YES      NO
  157. Power Macintosh 7100/66               |    YES     NO    |   YES      OK
  158. Power Macintosh 7100/80               |    YES     NO    |   YES      NO*
  159. Power Macintosh 7200 Series           |    YES•    NO    |   NO•      NO
  160. Power Macintosh 7500 Series           |    YES•    NO    |   NO•      NO
  161. Power Macintosh 7600 Series           |    YES•    NO    |   NO•      NO
  162. Power Macintosh 8100/80               |    YES     NO    |   YES      OK
  163. Power Macintosh 8100/100, 8100/110    |    YES     NO    |   YES      NO*
  164. Power Macintosh 8500 Series           |    YES•    NO    |   NO•      NO
  165. Power Macintosh 9500 Series           |    YES•    NO    |   NO•      NO
  166. --------------------------------------+------------------+------------------
  167. MACINTOSH WORKGROUP SYSTEMS           |                  |
  168.                                       |                  |
  169. Workgroup Server 95                   |    YES     NO    |   YES      NO
  170. Workgroup Server 8150                 |    YES     NO    |   YES      NO
  171. Workgroup Server 9150                 |    YES•    NO    |   NO•      NO
  172. --------------------------------------+------------------+------------------
  173.  
  174. End_Table
  175.  
  176. * These Power Macintosh computers included the Connectix Desktop Utility (CDU) software. The Connectix Desktop Utility makes these units Energy Star compliant.
  177.  
  178. • Use Energy Saver 2.0.x included with System 7.5.2 for this function.
  179.  
  180.  
  181. This article was published in the "Information Alley":
  182. Volume II, Issue 8, Page 6
  183.  
  184.  
  185. Article Change History:
  186. 01 Oct 1996 - Added current models.
  187. 24 Sep 1996 - Added 5400 and 6400.
  188. 23 Sep 1996 - Corrected typo.
  189.  
  190. Copyright 1995-96, Apple Computer, Inc.
  191.  
  192. ======================================================================
  193.  
  194. Created:       7/10/95
  195. Author:        78/MB