ITK Telekommunikation AG
Tel.: (+49)231/9747-0
Emil-Figge-Strasse 80
D-44227 Dortmund
www.itk.de
Actual product information - Addendum to printed documentation
==============================================================
Contents
========
1. General
2. System Requirements
3. Capi2.0
4. X.25 Support
5. Network Protocol Variants
6. Leased Lines
7. Installation under Windows NT 3.51
8. Installation under Windows NT 4.0
9. Installation under DOS
10. Certification
11. Problems / Remarks / History
1. General
===========
This version includes the download software
V3.00 for the ix1-basic board
and the PC drivers for Windows NT and MS DOS.
This software is a part of the ix1 Installation and Interfaces manual.
This version of NT-drivers supports the ix1-basic board with ISA or
PCI bus interface.
With a separate download software and a fax/modem expansion it
supports also the modem operation via CAPI 2.0.
The bin file can be loaded from the express server (file name "ixmodem") or
from our web-server.
To use this bin file you have two possibilities:
a) Before the software installation copy the file "ix.bin" on your copy of the
installation diskette
b) Exchange the file "ix.bin" in the directory
[currentInstallation]\system32\itk (usually c:\WINNT351\system32\itk)
by the file "ixmodem" from the express server.
2. System Requirements
======================
You need the following system requirements in order to use the ix1-basic board
under Windows NT:
for the ix1-basic ISA: 1 free 16 bit ISA/EISA slot for the ix1-basic ISA
or
1 of the following free interrupts:
IRQ 5, 9, 10 or 11
8 free port addresses from one of the following
address ranges:
-0x380-0x387
-0x388-0x38F
-0x390-0x397
-0x398-0x39F
-0x3A0-0x3A7(hardware version 1.2 and higher)
-0x3A8-0x3AF(hardware version 1.2 and higher)
for the ix1-basic PCI: 1 free PCI slot for the ix1-basic PCI
1 free interrupt (IRQ) ix1-basic PCI supports all
available interrupts
3 blocks from port addresses
(64 Byte, 8 Byte and 8 Byte)
all possible addresses are supported
3. CAPI2.0
==========
At the application interface "DLL" the Windows NT driver supports exclusively
CAPI 2.0. On the other hand, the "device driver" interface is a "multiple" CAPI
interface. This means that it supports CAPI1.1, CAPI2.0 and CAPIplus. CAPI1.1,
CAPI2.0 and CAPIplus applications can be started at the same time.
The following B channel protocols are supported according to CAPI1.1 supplements:
* Bit Transparent,
* HDLC Transparent,
* V.110,
* T.90
* ISO 8208 and
* Fax group 3 with 14400 bit/s
The following B channel protocols are supported according to CAPI2.0:
* Bit Transparent,
* HDLC Transparent,
* T.30,
* X.75,
* Modem and
* LAPD for D channel X.25,
* T.90 NL and
* ISO 8208
For the protocols modem and T.30 the fax/modem hardware expansion is required.
4. X.25 Support
===============
This software supports the following X.25 modes:
B channel: X.31 Case A (no bitrate adaption)
X.31 Case B
D channel: X.31 Case B
5. Network Protocol Variants
============================
The default D channel protocol is set to Euro-ISDN (DSS-1).
To use another D channel protocol the ix1 board has to be configured by using
the tool SETLINE under MS DOS. In order to start SETLINE you have boot the PC
under MS DOS.
The use of SETLINE is described in the ix1 Installation and Interfaces manual.
The standard scope of delivery for the board software contains
the following protocols:
Euro protocol (Euro-ISDN/NET3/DSS-1),
1TR6 (Germany),
VN3 (France),
Norway Phase 1 (Norway),
Q.931 (CCITT blue book),
Cornet N and
ECMA Q.SIG.
If you wish to use the protocol type VN4 (France) then set Q.931.
The protocol DSS1-TK is designed for PBXs that are not supporting the
information element "sending complete".
Now some examples for settings: SETLINE -D 0 <RETURN> select 1TR6
or
SETLINE -D 15 <RETURN> select DSS1-TK
or
SETLINE -D 8 <RETURN> select Norway Phase 1
(Norway)
6. Leased Lines
===============
The ix1 software for the ix1-basic board supports the following leased lines in
the area of the Deutsche Telekom AG:
a) D64S (0 D channel, 1 B channel)
(The device driver interface is actually supported only via CAPIplus.)
b) DS01/TS01 (1 D channel, 1 B channel)
c) DS02/TS02 (1 D channel, 2 B channels)
The different types of lines can be set with SETLINE
(see point 5. Network protocol variants):
a) D64S (0 D channel, 1 B channel)
The settings for NT-TE side are ignored, because no D channel is available
For the bandwidth set bit 3 on 2x64 Kbit.
The Line Access value is therefore:
10111=23 (dez) (setline -1 23)
b) DS01/TS01 (1 D channel, 1 B channel)
Both subscribers (A and B) of leased lines have to be configured
differently for a proper operation.
Bit 2 must be set:
- on A of NT-side and
- on B of TE-side.
For the bandwidth set bit 3 on 2x64 Kbit.
The Line Access values are therefore:
A (NT) = 00111 = 7 (setline -d 0 -l 7)
B (TE) = 00011 = 3 (setline -d 0 -l 3)
c) DS02/TS02 (1 D channel, 2 B channel)
Both subscribers (A and B) of leased lines have to be configured
differently for a proper operation.
Bit 2 must be set:
- on A of NT-side and
- on B of TE-side.
For the bandwidth set bit 3 on 1x128 Kbit this means that both
B channels are bundled.
The Line Access values are therefore:
A (NT) = 01111 = 15(dez) (setline -d 0 -l 15)
B (TE) = 01011 = 11(dez) (setline -d 0 -l 11)
7. Installation under Windows NT 3.51
=====================================
(1) In Windows NT double click the icon "Main".
(2) Double click on "Control Panel".
(3) Double click on "Network".
(4) Click on "Add Adapter".
(5) In the dialog box "Add Network Adapter" choose the option
" <Others> Requires disk from manufacturer"
(last point on the appearing list).
(6) Click on "Continue".
You are asked to insert the installation diskette in drive A:\
(7) Insert the installation diskette in drive A:\
(8) Click on ITK ix1-basic and confirm with "OK".
Windows NT setup copies all necessary files in the system directory of Windows NT.
!
! For the PCI board it is not necessary to execute steps 9 to 17 because your PC
! detects the necessary resources by itself.
!
(9) Choose the register tab "Resources".
(10) Click on the option of "Interrupt".
The possible interrupt values are displayed.
(11) Please take note of these values.
(12) Activate the window "Administrative Tools" of Windows NT now.
(13) Double click the icon "Windows NT Diagnostics".
(14) Choose the window "IRQ/Port Status".
You can ascertain which interrupts offered by ITK ix1-basic are not yet defined.
(15) Go back to the register tab "Resources" of "Properties of ITK ix1-basic".
(16) In the window "IRQ/Port Status" choose the interrupt(s) which is/are
not yet defined.
(17) Usually you can leave the default value of IO Base Address and
confirm the settings with "OK".
If you have configured the ix1-basic ISA board as EISA, enter the EISA slot
in which the board has been installed.
The dialog box "Network settings" is displayed again:
In the dialog box "Installed Adapter Cards" you can now see the ITK ix1-basic.
(18) Click on "OK".
Different Windows NT messages about the update, e.g. the network setting.
Before you answer the last message "Network Settings Change",
(19) Remove the installation diskette from drive A:\
(20) Click on "Restart Now" in the window "Network Settings Change"
The driver installation is completed and Windows NT will be restarted.
After the restart of Windows NT check whether the ITK ix1-basic was installed
correctly. Execute the following steps:
(1) Double click in Windows NT on the icon "Main".
(2) Double click on the icon "Control Panel".
(3) Double click on the icon "Devices".
A list with all drivers is displayed. Search for the driver
"ITK_ix1-active Treiber".
The ITK ix1-basic was installed correctly if the
"Status" is displayed as "Started".
If this is not the case, execute the following steps:
(1) Double click in Windows NT on the icon "Administrative Tools"
(2) Click on the "Event Viewer"
In the list displayed you find error descriptions.
To resolve the problem execute the following steps:
You can update the settings of ITK ix1-basic in the dialog box "Network Settings".
(1) Click in the dialog box "Network Settings" on ITK ix1-basic.
(2) Click on "Configure".
(3) Change in the register tab "Resources" the appropriate settings.
(4) Confirm with "OK".
When installing from the installation diskette the files needed for Windows NT are
copied on the hard disk in the corresponding directories for the NT installation.
The standard settings for the ITK ix1-basic board have the following parameters:
D channel protocol: DSS-1
bus configuration : point-to-multipoint
TEI: The TEI value is set on "Auto"
if you have to configure other values, you have to load (see point 8) the DOS-CAPI
from the diskette (PC must be booted under DOS !).
You can change the configuration with the utility setline.exe
(see in the manual chapter 4.7, SETLINE).
8. Installation under Windows NT 4.0
=====================================
(1) In Windows NT, click on the button "Start".
(2) Highlight "Settings".
(3) Click on "Control Panel".
(4) Click on "Network"
The dialog box "Network" will appear.
(5) Choose the register tab "Adapters" and click on "Add"
The dialog box "Select Network Adapter" will appear.
(6) In the dialog box "Select Network Adapter" click on "Have Disk..."
You are asked to insert the installation diskette in drive A:\
(7) Insert the installation diskette in drive A:\
The dialog box "Select OEM Option" will appear.
(8) Click on "ITK ix1-basic" and confirm with "OK".
Windows NT setup copies all the necessary files in the system directory
of Windows NT
The window "Properties of ITK ix1-basic" appears.
(9) In the register tab "General":
Usually no settings have to be made. In the installation from diskette
the binary- and the boot-files are copied into the system directory of
Windows NT.
In the respective files information about the version are displayed.
Settings in the register tab will be necessary when you have copied current
versions of the binary- and boot-files in a directory chosen by yourself.
In this case you have to enter the directory into the corresponding boxes
of the files.
(10) Configure your ISDN connection in the register tab "Line".
! For the PCI board, it is not necessary to execute steps 11 to 18 !
! because your PC detects the necessary ressources by itself. !
(11) Choose the register tab "Resources"
(12) Click on the option of "Interrupt"
The possible interrupt values are displayed.
(13) Please note down these values.
(14) Now activate the window "Windows NT Diagnostics".
For this, click on the button "Start". Highlight "Program".
Highlight "Administrative Tools (Common).
Click on "Windows NT Diagnostics".
(15) Choose the register tab "Resources"
(16) Choose IRQ.
You can find out which interrupts offered by ITK ix1-basic are not yet defined.
(17) Return to the register tab "Ressources of Properties of ITK ix1-basic".
(18) In the window "IRQ/Port Status" choose the interrupt(s) which is/are
not yet defined.
(19) Usually you do not have to alter the default value of I/O Base Address.
In this case, confirm the settings with "OK".
If you have configured the ITK ix1-basic ISA board as EISA, enter the address
range of the EISA slot in which the board has been installed.
The dialog box "Select Network Adapter" is displayed again: you can now see the
ITK ix1-basic.
(20) Click on "OK".
Different Windows NT messages about the update (e.g. the network settings)
appear.
Before you reply the last message "Network Settings Change",
(21) Remove the installation diskette from drive A:\
(22) In the window "Network Settings Change" click on "Yes".
The driver installation is completed and Windows NT will be restarted.
After the restart of Windows NT check whether the ITK ix1-basic was installed
properly. For this, execute the following steps:
(1) Click on the button "Start"
(2) Highlight "Settings"
(3) Click on "Control Panel"
(4) Double click on "Devices"
The window "Devices" will apppear. A list with all the drivers is displayed
Search for the driver ITK ix1-active driver.
The ITK ix1-basic was installed properly if the "Status"
is displayed as "Started".
Then: (5) Click on "Close".
If this is not the case, execute the following steps:
(1) Click on the button "Start".
(2) Highlight "Programs".
(3) Highlight "Administrative Tools (Common)".
(4) Click on "Event Viewer".
A list of error descriptions is displayed.
(5) Double click on the driver ITK_ix1_active.
A detailed error description is given.
(6) Click on "OK".
In order to resolve the problem execute the following steps:
You can update the settings of ITK ix1-basic in the register tab "Adapters"
in the dialog box "Network".
(1) In the register tab "Adapters" click on ITK ix1-basic.
(2) Click on "Properties".
(3) In the register tab "Resources" change the appropriate settings.
(4) Confirm with "OK"
The standard settings for the ITK ix1-basic board have
the following parameters:
D-channel protocol: DSS-1
Bus configuration: point-to-multipoint
TEI: the TEI-value is set to "Auto"
If you have to configure other values, you must load the DOS-CAPI from the
diskette (PC must be booted under DOS!). You can then change the configuration
with the utility SETLINE.
9. Installation under DOS
==========================
If your PC has been booted under DOS (with the tools it is possible to generate a
diskette that is able to boot under DOS) you can run the supplied batch file
CAPI.BAT with following parameters:
CAPI <RETURN> load the board and the PC driver
or
CAPI -D <RETURN> unload the PC driver (IXCAPI.COM)
or
CAPI ? <RETURN> displays the description of the possible
parameters for CAPI.BAT
This additional parameter is not mentioned in the manual.
10. Certification
=================
The ix1 boards with ISA bus and PCI bus are licensed by the german "Bundesamt fⁿr
Zulassungen in der Telekommunikation" (BZT) with the number A103702C and D128251H.
The ISA board was licensed with the CE number CE 0167X in Belgium, Denmark,
Finland, Great Britain, Ireland, Italy, Luxembourg, The Netherlands, Norway,
Austria, Portugal, Spain and Sweden.
The PCI board was licensed under the number CE 0560X in the above mentioned
countries. In France the ISA board is licensed with the number 95231B.
In Switzerland the ISA board is licensed with the number 95.0488.I.N,
the PCI board is licensed with the number 96.0600.I.N.
The licenses were issued for point-to-multipoint connections,
point-to-point connections (NT-1) and for leased lines.
For more information contact the product support with the extension -250.
11. Problems / Remarks / History
=================================
a) In this version the fax/modem expansion is recognized automatically.
b) The actual version is not compatible to previous versions regarding the
compression.
Data connections between the actual version and previous versions work
uncompressed.
c) The update download file needs the supplied bootfile ixboot.scr.
d) For each ITK ix1-basic board you have to execute an installation.
An existing installation can -at the moment- only be deinstalled completely.
This means that boards can't be deinstalled separately.
If you wish to operate two boards instead of three, you first have to
deinstall all boards and then execute the installation for the remaining
two boards.
e) If you wish to install an ITK ix1-basic PCI board in a PC with several
PCI buses (not PCI slots!) you have to enter the chosen bus in the
registry database (if it is not already set to the default bus 0).
In case of questions please contact our support.