  1. ******************************************************
  2. *                                                    *
  3. * FastTrak Utility Diskette Version 1.30 Build 42    *
  4. *                                                    *
  5. ******************************************************
  6.  
  7. ====================
  8. Contents on the disk
  9. ====================
  10. UTIL           <DIR>    Directory that contains setup files for FastCheck
  11.                         utility as follows:
  12.   README   TXT          This file
  13.   SETUP    EXE          Setup utility to install FastCheck
  14.   LAYOUT   BIN          Setup file
  15.   SETUP    BMP          Setup file
  16.   DATA1    CAB          Setup file
  17.   _SYS1    CAB          Setup file
  18.   _USER1   CAB          Setup file
  19.   LANG     DAT          Setup file
  20.   OS       DAT          Setup file
  21.   _SETUP   DLL          Setup file
  22.   _ISDEL   EXE          Setup file
  23.   _INST32I EX_          Setup file
  24.   SETUP    INI          Setup file
  25.   SETUP    INS          Setup file
  26.   SETUP    LID          Setup file
  27.   DATA     TAG          Setup file
  28.   INSTALL  TXT          Text file
  29.  
  30. ================
  31. Software Version
  32. ================
  33. FastCheck utility for Promise FastTrak  1.30 (Build 42)
  34. FastTrak Log Service for Windows NT     1.30 (Build 42)
  35. FastTrak DMI Service for Windows NT     1.30 (Build 42)
  36.  
  37. To install FastCheck, please use the SETUP.EXE.
  38.  
  39. ==================
  40. FastTrak Utilities
  41. ==================
  42.  
  43. The FastCheck utility is used to monitor or perform maintenance
  44. on a FastTrak Mirrored (RAID 1) or Striped/Mirrored (RAID 0/1) 
  45. array. Visual and audible messages are available to warn of 
  46. possible problems with the disk array or controller. This utility
  47. runs under Windows 95-98, Windows Millennium, Windows NT 4.0,
  48. and Windows 2000.
  49.  
  50.  
  51. ========================
  52. FastCheck Utility README
  53. ========================
  54.  
  55. ------------
  56. Installation
  57. ------------
  58.  
  59. Refer to the INSTALL section above for instructions on installing
  60. the FastCheck utility.
  61.  
  62. ---------------------------------------
  63. Getting Around in the FastCheck Utility
  64. ---------------------------------------
  65.  
  66. Task Bar Icon
  67. On the Windows 95-98/NT taskbar, the FastCheck icon appears as a stack
  68. of disks. To launch the utility double-click on the task bar icon.
  69. Windows NT 3.51 does not have a task bar; FastCheck will appear 
  70. as a minimized icon on the desktop. 
  71.  
  72. Array Tab View
  73. From the Array view, status is shown for drives in the array. On 
  74. the left window pane, drive models are shown. On the right pane, 
  75. array type, mapping, and size are displayed. This is followed by 
  76. array status. The status will be either working, error, or 
  77. degraded. If an error is found, the array needs to be synchronized.
  78. If degraded, a disk has failed or is not responding and most likely
  79. needs to be physically replaced followed by a data rebuild.
  80.  
  81. Controller Tab View
  82. This view displays configuration and system resource data for the
  83. controller. The left pane shows the actual connector Channel and 
  84. Master/Slave ID of attached IDE drives. The right pane lists the 
  85. PCI Slot#, IRQ, and Bus Master address.
  86.  
  87. Options Tab View
  88. The FastCheck Utility uses pop-up text for instruction on options. 
  89. Hover the mouse cursor for description.
  90.  
  91.  
  92. -------------------------------------
  93. Configuration and Maintenance Options
  94. -------------------------------------
  95.  
  96. To run a maintenance operation, simply right click the icon of the 
  97. array and choose either synchronization or rebuild array functions.
  98.  
  99. - SYNCHRONIZATION
  100.  
  101. This is a maintenance operation for Mirrored (RAID1) arrays. It 
  102. will compare data on drives for differences.  If there are 
  103. differences it will automatically copy data from the first disk to 
  104. the second disk in the array. This needs to be performed 
  105. periodically to maintain data integrity. To synchronize, choose the 
  106. Array Tab View, right click the array, and choose "Synchronize" 
  107. from the context menu. You can also "Schedule the array
  108. synchronization" under the Options Tab view.
  109.  
  110. - EVENT LOG FILE
  111.  
  112. In this Options Tab View, you may keep a record of alerts and 
  113. status reports of the FastTrak arrays. Click the "Use Log file" 
  114. check box to enable this feature followed by a logfile name. If 
  115. a filename is entered but the path is left blank, the default 
  116. directory will be the same as the FastCheck utility. Typically, 
  117. this directory would be "C:\Program Files\Promise\Fasttrak". 
  118. Because this file must be locked while the FastCheck utility is
  119. running, you must exit the utility in order for the log file to
  120. be read.
  121.  
  122. - Use NT System Event Log
  123.  
  124. If this option is checked, events and errors will be written
  125. to the Windows NT Event Log. You can view these events by 
  126. clicking on the Start button then going to PROGRAMS -> 
  127. ADMINISTRATIVE TOOLS (COMMON) -> EVENT VIEWER. From the Event
  128. Viewer menu bar choose "Log", and then check "Application".
  129. In the "Source" column, all FastCheck events will show up
  130. with the designation "FastCheck", or "FastTrakSvc".
  131. Double-clicking on an event will display additional
  132. information.
  133.  
  134. - REBUILD
  135.  
  136. This user command will effectively copy/overwrite data from an 
  137. existing data drive in the array onto a blank drive. The operation 
  138. will be typically used when a failed drive has been replaced with 
  139. a new drive. To perform a Rebuild, choose the Array Tab View, right 
  140. click the array, and choose Rebuild from the context menu.
  141.  
  142. When a spare drive is installed, a rebuild will automatically be
  143. performed from the working drive. You can disable the automatic
  144. rebuild by turning on the "Disable Hot Spare/Auto Rebuild" option.
  145.  
  146.  
  147.  
  148.  