home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
Chip 2003 September (Special)
/
Chip-Special_2003-09_cd.bin
/
vypal
/
instant
/
download
/
InstantCopy.msi
/
Cabs.w1.cab
/
vobhw.dll
/
0
/
TEXT
/
1000
next >
Wrap
Text File
|
2003-01-30
|
4KB
|
103 lines
0 00 00 NO ADDITIONAL SENSE INFORMATION
B 00 06 I/O PROCESS TERMINATED, PLAY OPERATION ABORTED
2 05 00 LOGICAL UNIT DOES NOT RESPOND TO SELECTION
5 07 00 MULTIPLE PERIPHERAL DEVICES SELECTED
4 08 00 LOGICAL UNIT COMMUNICATION FAILURE
4 08 01 LOGICAL UNIT COMMUNICATION TIME-OUT
4 08 02 LOGICAL UNIT COMMUNICATION PARITY ERROR
4 08 03 LOGICAL UNIT COMMUNICATION CRC ERROR (ULTRA-DMA/32)
6 0A 00 ERROR LOG OVERFLOW
1 0B 00 WARNING
1 0B 01 WARNING - SPECIFIED TEMPERATURE EXCEEDED
1 0B 02 WARNING - ENCLOSURE DEGRADED
5 1A 00 PARAMETER LIST LENGTH ERROR
4 1B 00 SYNCHRONOUS DATA TRANSFER ERROR
5 20 00 INVALID COMMAND OPERATION CODE
5 24 00 INVALID FIELD IN CDB
5 25 00 LOGICAL UNIT NOT SUPPORTED
5 26 00 INVALID FIELD IN PARAMETER LIST
5 26 01 PARAMETER NOT SUPPORTED
5 26 02 PARAMETER VALUE INVALID
5 26 03 THRESHOLD PARAMETERS NOT SUPPORTED
5 26 04 INVALID RELEASE OF ACTIVE PERSISTENT RESERVATION
6 28 00 NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED
6 28 01 IMPORT OR EXPORT ELEMENT ACCESSED
6 29 00 POWER ON, RESET, OR BUS DEVICE RESET OCCURRED
6 29 01 POWER ON OCCURRED
6 29 02 SCSI BUS RESET OCCURRED
6 29 03 BUS DEVICE RESET FUNCTION OCCURRED
6 29 04 DEVICE INTERNAL RESET
6 2A 00 PARAMETERS CHANGED
6 2A 01 MODE PARAMETERS CHANGED
6 2A 02 LOG PARAMETERS CHANGED
6 2A 03 RESERVATIONS PREEMPTED
5 2C 00 COMMAND SEQUENCE ERROR
6 2F 00 COMMANDS CLEARED BY ANOTHER INITIATOR
4 34 00 ENCLOSURE FAILURE
4 35 00 ENCLOSURE SERVICES FAILURE
5 35 01 UNSUPPORTED ENCLOSURE FUNCTION
2 35 02 ENCLOSURE SERVICES UNAVAILABLE
4 35 03 ENCLOSURE SERVICES TRANSFER FAILURE
5 35 04 ENCLOSURE SERVICES TRANSFER REFUSED
5 3D 00 INVALID BITS IN IDENTIFY MESSAGE
2 3E 00 LOGICAL UNIT HAS NOT SELF-CONFIGURED YET
4 3E 01 LOGICAL UNIT FAILURE
4 3E 02 TIMEOUT ON LOGICAL UNIT
6 3F 00 TARGET OPERATING CONDITIONS HAVE CHANGED
6 3F 01 MICROCODE HAS BEEN CHANGED
6 3F 02 CHANGED OPERATING DEFINITION
6 3F 03 INQUIRY DATA HAS CHANGED
4 40 00 RAM FAILURE (SHOULD USE 40 NN)
4 40 NN DIAGNOSTIC FAILURE ON COMPONENT NN (80H-FFH)
4 41 00 DATA PATH FAILURE (SHOULD USE 40 NN)
4 42 00 POWER-ON OR SELF-TEST FAILURE (SHOULD USE 40 NN)
5 43 00 MESSAGE ERROR
4 44 00 INTERNAL TARGET FAILURE
B 45 00 SELECT OR RESELECT FAILURE
4 46 00 UNSUCCESSFUL SOFT RESET
4 47 00 SCSI PARITY ERROR
B 48 00 INITIATOR DETECTED ERROR MESSAGE RECEIVED
B 49 00 INVALID MESSAGE ERROR
4 4A 00 COMMAND PHASE ERROR
4 4B 00 DATA PHASE ERROR
4 4C 00 LOGICAL UNIT FAILED SELF-CONFIGURATION
B 4D NN TAGGED OVERLAPPED COMMANDS (NN = QUEUE TAG)
B 4E 00 OVERLAPPED COMMANDS ATTEMPTED
4 54 00 SCSI TO HOST SYSTEM INTERFACE FAILURE
5 55 00 SYSTEM RESOURCE FAILURE
6 55 01 SYSTEM BUFFER FULL
6 5A 00 OPERATOR REQUEST OR STATE CHANGE INPUT
6 5A 01 OPERATOR MEDIUM REMOVAL REQUEST
6 5A 02 OPERATOR SELECTED WRITE PROTECT
6 5A 03 OPERATOR SELECTED WRITE PERMIT
6 5B 00 LOG EXCEPTION
6 5B 01 THRESHOLD CONDITION MET
6 5B 02 LOG COUNTER AT MAXIMUM
6 5B 03 LOG LIST CODES EXHAUSTED
1 5D 00 FAILURE PREDICTION THRESHOLD EXCEEDED - Predicted Logical Unit Failure
1 5D 01 FAILURE PREDICTION THRESHOLD EXCEEDED - Predicted Media Failure
1 5D 03 FAILURE PREDICTION THRESHOLD EXCEEDED - Predicted Spare Area Exhaustion
1 5D FF FAILURE PREDICTION THRESHOLD EXCEEDED (FALSE)
6 5E 00 LOW POWER CONDITION ON
6 5E 01 IDLE CONDITION ACTIVATED BY TIMER
6 5E 02 STANDBY CONDITION ACTIVATED BY TIMER
6 5E 03 IDLE CONDITION ACTIVATED BY COMMAND
6 5E 04 STANDBY CONDITION ACTIVATED BY COMMAND
4 65 00 VOLTAGE FAULT
4 67 00 CONFIGURATION FAILURE
4 67 01 CONFIGURATION OF INCAPABLE LOGICAL UNITS FAILED
4 67 02 ADD LOGICAL UNIT FAILED
4 67 03 MODIFICATION OF LOGICAL UNIT FAILED
4 67 04 EXCHANGE OF LOGICAL UNIT FAILED
4 67 05 REMOVE OF LOGICAL UNIT FAILED
4 67 06 ATTACHMENT OF LOGICAL UNIT FAILED
4 67 07 CREATION OF LOGICAL UNIT FAILED
2 68 00 LOGICAL UNIT NOT CONFIGURED
6 6A 00 INFORMATIONAL, REFER TO LOG
6 6B 00 STATE CHANGE HAS OCCURRED
6 6B 01 REDUNDANCY LEVEL GOT BETTER
6 6B 02 REDUNDANCY LEVEL GOT WORSE
3 6C 00 REBUILD FAILURE OCCURRED
3 6D 00 RECALCULATE FAILURE OCCURRED
4 6E 00 COMMAND TO LOGICAL UNIT FAILED