home *** CD-ROM | disk | FTP | other *** search
/ CP/M / CPM_CDROM.iso / cpm / gendoc / anti-aps.ckt < prev    next >
Internet Message Format  |  1985-06-28  |  2KB

  1. Date: Wednesday, 26 June 1985
  2. From: John Blalock
  3. Re:   Anti-APS Circuit
  4.  
  5. Summertime and the summer showers and power outages are almost here again.
  6. Most of us use the standard surge and/or transient suppressors to protect
  7. our systems from power line problems, but I also recommend use of the
  8. following circuit:
  9.  
  10.  
  11.                 ANTI-APS CIRCUIT
  12.  
  13.  
  14.                                                                    AC HIGH
  15.               / Main Switch                        ----------O------------->  
  16.        ,----o/ o-----------------------o-----------/\            TO SYSTEM
  17.        o       S1                      |                                   
  18.       (_  Main                         |           ----------O-,           
  19.   F1    ) Fuse                ,--------o-----------/\          |           
  20.        o                      |            ,-------------------'           
  21.        |          Momentary |_o S2         |      -------                  
  22. To 120 |          Start     | o            o------|     | 120 VAC DPST-NO  
  23. VAC    |          Switch      |            |      | K1  | RELAY            
  24.   _  HI|                      '------------'      |     |----.             
  25. -| \---'                                          -------    |             
  26. =|  |---|> Chassis Ground                                    |     AC NEUT   
  27. -|_/---------------------------------------------------------o------------->  
  28.      NEUT                                                        TO SYSTEM
  29.  
  30. Closing S1 does not turn on AC to the system, it just enables the
  31. circuit.  Once S1 is closed, closing momentary switch S2 energizes K1.
  32. One set of contacts on K1 provides AC to the system, the other
  33. contacts are in parallel with S2 and latch K1 on until S1 is opened or
  34. the main AC source goes off momentarily.  You need this circuit if you
  35. have a "public utility" known to have frequent, unpredictable, power
  36. outages.  If there is a momentary power failure, your system will shut
  37. down until you restart it by pressing S2.  This prevents frequent
  38. up/down AC surges like we see in Phoenix from being seen by your
  39. system.  Make sure that the current ratings of F1, S1, and K1 exceed
  40. your requirements.
  41.  
  42. John Blalock, W7AAY
  43.  
  44. uucp:     ...{amd,decvax,hao,ihnp4,seismo}!noao!terak!jb
  45. phone:     (602) 998-4800
  46. us mail: Terak Corp., 14151 N. 76th St., Scottsdale, AZ 85260
  47.          \\\\\
  48.           -----> Soon to be part of CalComp, A Sanders Company
  49.