; MXO-HP1.ASM -- Hewlett Packard overlay file for MEX114. 04/27/89
;
; This overlay adapts the MEX114 program to the HP125 Series 100.
;
; You will want to look this file over carefully. There are a number of
; options that you can use to configure the program to suit your taste.
; You use the AIDS and SOFT KEYS to configure baud rate and other para-
; meters.
;
; The HP125 uses two Z80's one for I/O and the other for crunching.
; Needless to say HP doesn't let the number crunching Z80 talk directly
; to the I/O ports, so direct communication with the ports is out. As
; luck would have it HP did include RDR: and PUN: routines, these rou-
; tines have been used in this implementation. NOTE: Special routines
; were required to device map the PUN: and RDR: to PORT 1 and to get all
; 8 bits of data in and out of the port.
;
; Edit this file for your preferences then follow the "TO USE:" example
; shown below.
;
; TO USE: First edit this file filling in answers for your own
; equipment. Then assemble with ASM.COM or equivalent
; assembler. Then use MLOAD to overlay the the results
; of this program to the original .COM file:
;
; A>MLOAD MEX-HP1=MEX114.COM,MXO-HP1.HEX ;Overlay MEX114.COM to produce
; MEX-HP1.COM
;
; = = = = = = = = = = = = = = = = = =
;
; 04/27/89 - Adapted from M7-HP1.ASM for use with MEX114 - Mike Freeman
; 11/11/83 - Renamed to M7-HP1.ASM, no changes - Irv Hoff
; 07/20/83 - Renamed to work with MDM712 - Irv Hoff
; 07/20/83 - Revised to work with HP125 - John Bingel
; 07/01/83 - Revised to work with MDM711 - Irv Hoff
; 07/01/83 - Revised to work with MDM710 - Irv Hoff
; 05/27/83 - Updated to work with MDM709 - Irv Hoff
; 05/15/83 - Revised to work with MDM708 - Irv Hoff
; 04/11/83 - Updated to work with MDM707 - Irv Hoff
; 04/04/83 - First version of this file - Irv Hoff
;
; = = = = = = = = = = = = = = = = =
;
BDOS: EQU 05H
BELL: EQU 07H ;bell
CR: EQU 0DH ;carriage return
ESC: EQU 1BH ;escape
LF: EQU 0AH ;linefeed
;
YES: EQU 0FFH
NO: EQU 0
;
;
; Change the following information to match your equipment
;
RDRST: EQU 70FFH ;READER STATUS SFC
RDRIN: EQU 03H ;READER INPUT SFC
PUNOUT: EQU 04H ;PUNCH OUTPUT SFC
BITS8: EQU 73FFH ;8 BIT SFC
BITS7: EQU 74FFH ;RESET TO NORMAL 7 BIT SFC
JVT: EQU 7EFFH ;JUMP VECTOR TABLE SFC
MODRCVB: EQU 1 ;BIT TO TEST FOR RECEIVE
MODRCVR: EQU 1 ;VALUE WHEN READY
MODSNDB: EQU 0 ;BIT TO TEST FOR SEND
MODSNDR: EQU 0 ;VALUE WHEN READY
;
ORG 100H
;
;
; Change the clock speed to suit your system
;
DS 3 ;(for "JMP START" instruction)
;
PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
SMARTMODEM: DB NO ;yes=HAYES Smartmodem, no=non-PMMI 104H
TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H
;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED: DB 5 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
;6=2400 7=4800 8=9600 9=19200 default
BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
;default time to send character in ter-
;minal mode file transfer for slow BBS.
CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
;default time for extra wait after CRLF
;in terminal mode file transfer
NOOFCOL: DB 5 ;number of DIR columns shown 10AH
SETUPTST: DB NO ;yes=user-added Setup routine 10BH
SCRNTEST: DB NO ;Cursor control routine 10CH
ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH
;no=resend a record after a valid-NAK
BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
CRCDFLT: DB YES ;yes=default to CRC checking 10FH
TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
CONVBKSP: DB NO ;yes=convert backspace to rub 111H
TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H
ADDLF: DB NO ;no=no LF after CR to send file in 113H
;terminal mode (added by remote echo)
TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
TRANLOGON: DB YES ;yes=allow transmission of logon 115H
;write logon sequence at location LOGON
SAVCCP: DB YES ;yes=do not overwrite CCP 116H
LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
;no=external command if EXTCHR precedes
TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
LSTTST: DB YES ;yes=printer available on printer port 119H
XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH
;sending a file in terminal mode
XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
;sending a file in terminal mode
TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
IGNORCTL: DB NO ;yes=CTL-chars above ^M not displayed 11DH
EXTRA1: DB 0 ;for future expansion 11EH
EXTRA2: DB 0 ;for future expansion 11FH
BRKCHR: DB '@'-40H ;^@ = Send 300 ms. break tone 120H
NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
LOGCHR: DB 'L'-40H ;^L = Send logon 122H
LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
EXTCHR: DB '^'-40H ;^^ = Send next character 127H
;
;
DS 2 ; 128H
;
IN$MODCTL1: JMP INCTL ;in modem control port 12AH
DS 7
OUT$MODDATP: JMP OUTDATA ;out modem data port 134H
DS 7
IN$MODDATP: JMP INDATA ;in modem data port 13EH
DS 7
ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H
CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH
ANI$MODSNDB: MVI A,MODSNDB ! RET ;bit to test for send ready 14EH
CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H
DS 6 ; 156H
;
OUT$MODCTL1: NOP ! NOP ! RET ;out modem control port #2 15AH
OUT$MODCTL2: NOP ! NOP ! RET ;out modem control port #1 15DH
;
LOGONPTR: DW LOGON ;for user message. 160H
DS 6 ; 162H
JMP$GOODBYE: JMP GOODBYE ; 168H
JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
JMP$SETUPR: JMP SETUPR ; 177H
JMP$SPCLMENU: JMP SPCLMENU ; 17AH
JMP$SYSVER: JMP SYSVER ; 17DH
JMP$BREAK: JMP SENDBRK ; 180H
;
;
; Do not change the following six lines.
;
JMP$ILPRT: DS 3 ; 183H
JMP$INBUF DS 3 ; 186H
JMP$INLNCOMP: DS 3 ; 189H
JMP$INMODEM DS 3 ; 18CH
JMP$NXTSCRN: DS 3 ; 18FH
JMP$TIMER DS 3 ; 192H
;
;
; Routine to clear to end of screen. If using CLREOS and CLRSCRN, set
; SCRNTEST to YES at 010AH (above).
;
CLREOS: CALL JMP$ILPRT ; 195H
DB 0,0,0,0,0 ; 198H
RET ; 19DH
;
CLRSCRN: CALL JMP$ILPRT ; 19EH
DB 0,0,0,0,0 ; 1A1H
RET ; 1A6H
;
SYSVER: LXI B,BITS8 ;SFC 115 SET PORT 1 TO 8 BITS
CALL BDOS
CALL JMP$ILPRT ; 1A7H
;
;
; DEVICE MAP RDR: & PUN: TO USE PORT 1
;
DB 1BH,'&i0s25d2M',1BH,'&i10s16d2M',CR,LF
;
;
; NOW PRINT LOGON
;
DB 'Version for the HP125 Series 100'
DB CR,LF,LF,LF,0
;
; NOW SET UP READER ROUTINE SO WE REALLY GET 8 BITS
;
LHLD REAL ;GET REAL READER RTN ADDRESS
MOV A,H ;BEEN HERE BEFORE (I.E. "COLD" COMMAND)?
ORA L ;...
RNZ ;YES - DON'T DIDDLE JUMP TABLE/RTN ADDRESS
LXI B,JVT ;SFC 126
LXI D,JBUF ;ADDRESS OF JUMP BUFFER
CALL BDOS ;READ JUMP TABLE INTO JBUF
LHLD JUMP ;GET ADDRESS RETURNED IN JBUF
SHLD REAL ;AND STORE AS REAL RDRIN
LXI H,INEIGHT ;GET ADDRESS OF 8 BIT INPUT
SHLD JUMP ;AND STORE IN JBUF
MVI A,1 ;MOVE A WRITE CODE INTO A
STA FLAG ;STORE IT IN JBUF
LXI B,JVT ;SFC 126
LXI D,JBUF ;ADRESS OF JUMP BUFFER
CALL BDOS ;WRITE JUMP TABLE FROM JBUF
RET
;
;
; MODEM I/O PRIMITIVES
;
OUTDATA: PUSH B
PUSH D
PUSH H
MOV E,A ;MOVE OUTPUT BYTE FROM A TO E
MVI C,PUNOUT ;GET PUN: SFC
CALL BDOS ;OUTPUT BYTE
POP H
POP D
POP B
RET
;
INDATA: PUSH B
PUSH D
PUSH H
MVI C,RDRIN ;GET RDR: SFC
CALL BDOS ;GET BYTE FROM RDR:
POP H
POP D
POP B
RET
;
INEIGHT: CALL READIN ;BYPASS BIT 8 STRIP IN
MOV A,B ;RDR: ROUTINE
RET
;
INCTL: PUSH B
PUSH D
PUSH H
LXI B,RDRST ;GET RDR: STATUS SFC
CALL BDOS ;GET RDR: STATUS
POP H
POP D
POP B
RET
;.....
;
;
;-----------------------------------------------------------------------
;
; NOTE: You can change the SYSVER message to be longer or shorter. The
; end of your last routine should terminate by 0400H (601 bytes
; available after start of SYSVER) if using the Hayes Smartmodem
; or by address 0C00H (2659 bytes) otherwise.
;
;-----------------------------------------------------------------------
;
; You can put in a message at this location which can be called up with
; CTL-O if TRANLOGON has been set TRUE. You can use several lines if
; desired. End with a 0.
;
LOGON: DB 'How are you today?',CR,LF,0
;.....
;
;
; Routine to send a break tone to reset some time-share computers, if
; desired.
;
SENDBRK: MVI A,02H
CALL OUTDATA
RET
;.....
;
;
; Routine to put DTR low (to disconnect) and/or send a break tone.
;
GOODBYE:LXI B,BITS7 ;Reset DAta Comm 1 to pass 7-bit data only
CALL BDOS ;...
LHLD REAL ;Get real Reader routine address
SHLD JUMP ;and put it back into dispatch table
LXI H,0 ;RESET SO INIT WILL DIDDLE JUMP TABLE
SHLD REAL ;...
LXI B,JVT ;...
LXI D,JBUF ;...
CALL BDOS ;...
CALL JMP$ILPRT
;*** Delete this! *** DB 1BH,'E',0 ;COLD BOOT SYSTEM
DB 1BH,'&i0s25d8M' ;Unmap Data Comm 1 to Reader
DB 1BH,'&i10s16d9M',0;and Punch to Data Comm 1
RET
;.....
;
;
READIN: DB 0C3H ;JUMP OPCODE
REAL: DB 0,0 ;SAVE 2 BYTES FOR ADDRESS
JVN: DB 7 ;READER BIOS CODE
FLAG: DB 0 ;READ/WRITE CODE
OPCODE: DS 1 ;RESERVE 1 BYTE FOR JMP CODE
JUMP: DS 2 ;AND 2 BYTES FOR ADDRESS
JBUF: EQU JVN ;NAME ENTIRE BUFFER JBUF
;
;.....
;
;
; You can use this area for any special initialization or setup you may
; wish to include. Each must stop with a RET. You can check the other
; available overlays for ideas how to write your own routines if that
; may be of some help.
;
INITMOD: RET
;
SETUPR: RET
;
;
; If using the Hayes Smartmodem this is unavailable without a special
; change.
;
SPCLMENU: RET
;
;
; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
; 0C00H (without Smartmodem)
;.....
;
END
;