home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
CP/M
/
CPM_CDROM.iso
/
cpm
/
mex
/
mxo-hu11.asm
< prev
next >
Wrap
Assembly Source File
|
1994-07-13
|
23KB
|
722 lines
; MXO-HU11.ASM -- U.S. Robotics S-100 overlay for MEX11.COM adapted for
; V.86/07/27 Heath/Zenith-100
;
; This overlay follows MEX coventions and is all you need to get MEX running.
;
; Significant quantities of ideas and code for this program have been
; drawn from M7US-2.ASM, M712US.ASM and MXO-SM13.ASM and I am greatfully
; taking this opportunity to extend credit to the people involved in
; the development of these overlays.
;
; This version will assemble directly for a Z-100 using the S-100 bus
; auto dial/auto answer modem by US Robotics. The port switches on the
; modem board should be set to 20h 21h as follows:
;
; DIP SWITCH SEGMENT(S6) SLIDE SWITCH(J6)
; 4 3 2 1
; OFF OFF ON OFF UP
;
; You will want to look this file over carefully. There are a number of
; options that you can use to configure the program to suit your taste.
; This file places particular emphasis on using the Heath/Zenith "100"
; equipment. Much of the information contained here is not in the main
; file.
;
; This overlay is capable of setting the baud rate and sending breaks.
; Although disconnecting the modem is not supported by use of a function to
; lower DTR. However, the control-N and DSC commands still work, as they use
; "+++" which causes the U.S.R. S-100 modem to hang up. Some do-nothing time
; wasting statements have beeen added to the INITMODEM routine to slow the
; computer down for the modem. The regular U.S.R. S-100 modem initialization
; routine will not work reliably with computer clock speeds above 4 MHz.
;
; Baud rates supported are 150, 300, 600 and 1200. Note that 150 baud has
; been included in place of 110 baud which is not supported by the U.S.R.
; S-100 modem. (The SET command when entered without argument will with
; 150 baud selected still indicate 110 baud unless MEX.COM is patched. For
; MEX114.COM this may be done by changing the contents of address 4FF8 from
; 31H to 35H.)
;
; TO USE: First edit this file filling in answers for your own
; equipment. Then assemble with ASM.COM or equivalent
; assembler. Then use MLOAD.COM to overlay the the results
; of this program to the original .COM file:
;
; MLOAD MEX11.COM=MEXHU.COM,MXO-HU11
;
; Refer to MEX10.INF, MEX10.DOC and updates for complete
; instructions.
;
; = = = = = = = = = = = = = = = = = =
;
; 86/07/86 - Code added to GOODBYE to warn user if - Bo Gedda
; modem is still on line upon use of
; BYE, CPM and SYSTEM commands.
;
; 85/12/26 - Initialization changed to include reset of - Bo Gedda
; modem (RESETST and minor code added).
;
; 85/08/03 - Dial routine changed to allow conditional - Bo Gedda
; assembly for Swedish pulse dialing which
; is different for some crazy reason.
; Set SWEPU true to allow this option, which
; differs as follows:
;
; Number International Swedish
; of pulses # #
; ---------------------------------------
; 1 1 0
; 2 2 1
; 3 3 2
; 4 4 3
; 5 5 4
; 6 6 5
; 7 7 6
; 8 8 7
; 9 9 8
; 10 0 9
;
; 84/11/22 - Call in INITMOD modified to follow MEX - Bo Gedda
; conventions. SMANAL modified to exclude
; busy and include error code. SMDIAL
; modified to add extra 2 second delay
; before dialing.
;
; 84/09/09 - Initialization modified to allow other - Bo Gedda
; default baud rate then 300 baud
;
; 84/08/29 - First version of this file. - Bo Gedda
;
; = = = = = = = = = = = = = = = = = =
;
; Use the MEX "SET" command to change the baudrate when desired. Default
; baud rate may be set to 150, 300, 600 or 1200 by modifying MSPEED below.
;
; MEX service processor stuff
;
MEX EQU 0D00H ;address of the service processor
INMDM EQU 255 ;get char from port to A, CY=no more in 100 ms
TIMER EQU 254 ;delay 100ms * reg B
TMDINP EQU 253 ;B=# secs to wait for char, cy=no char
CHEKCC EQU 252 ;check for ^C from KBD, Z=present
SNDRDY EQU 251 ;test for modem-send ready
RCVRDY EQU 250 ;test for modem-receive ready
SNDCHR EQU 249 ;send a character to the modem (after sndrdy)
RCVCHR EQU 248 ;recv a char from modem (after rcvrdy)
LOOKUP EQU 247 ;table search: see CMDTBL comments for info
PARSFN EQU 246 ;parse filename from input stream
BDPARS EQU 245 ;parse baud-rate from input stream
SBLANK EQU 244 ;scan input stream to next non-blank
EVALA EQU 243 ;evaluate numeric from input stream
LKAHED EQU 242 ;get nxt char w/o removing from input
GNC EQU 241 ;get char from input, cy=1 if none
ILP EQU 240 ;inline print
DECOUT EQU 239 ;decimal output
PRBAUD EQU 238 ;print baud rate
PRNTBL EQU 237 ;get MEX format command table pointer
PRID EQU 236 ;print MEX ID string on console
PRINT EQU 9 ;MEX/BDOS print-string function call
;
BELL: EQU 07H ;bell
CR: EQU 0DH ;carriage return
ESC: EQU 1BH ;escape
LF: EQU 0AH ;linefeed
;
YES: EQU 0FFH
NO: EQU 0
FALSE EQU 0
TRUE EQU NOT FALSE
;
; SYSTEM CONSTANTS
;
TPULSE EQU 0105H ;TONE/PULSE FLAG IN MODEM OVERLAY
DIALV EQU 0162H ;LOCATION OF DIAL VECTOR IN OVERLAY
DISCV EQU 0165H ;LOCATION OF DISCONNECT VECTOR IN OVERLAY
;
ORG DIALV ;OVERLAY THE DIALING VECTOR
JMP DIAL
;
ORG DISCV ;OVERLAY THE DISCONNECT VECTOR
JMP DISCON
;
;
; Change the following information to match your equipment
;
SWEPU EQU FALSE ;SET TRUE IF SWEDISH TYPE PULSE
; DIALING IS REQUIRED THIS FORCES
; PULSE DIALLING
PORT: EQU 020H ;SET TO MATCH MODEM SWITCHES
MODCTL1: EQU PORT+1 ;MODEM CONTROL PORT
MODDATP: EQU PORT ;MODEM DATA IN PORT
MODDATO: EQU PORT ;MODEM DATA OUT PORT
MODDCDB: EQU 080H ;CARRIER DETECT BIT
MODDCDA: EQU 080H ;VALUE WHEN ACTIVE
MODRCVB: EQU 2 ;BIT TO TEST FOR RECEIVE
MODRCVR: EQU 2 ;VALUE WHEN READY
MODSNDB: EQU 1 ;BIT TO TEST FOR SEND
MODSNDR: EQU 1 ;VALUE WHEN READY
;
FRMER EQU 20H ;FRAMING ERROR
ORUNER EQU 10H ;OVERRUN ERROR
PARER EQU 08H ;PARITY ERROR
;
ORG 100H
;
;
; Change the clock speed to suit your system
;
DS 3 ;(for "JMP START" instruction)
;
PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
SMARTMODEM: DB YES ;yes=HAYES Smartmodem, no=non-PMMI 104H
TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
CLOCK: DB 45 ;clock speed in MHz x10, 25.5 MHz max. 106H
;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED: DB 1 ;0=150 1=300 2=450 3=600 4=710 5=1200 107H
;6=2400 7=4800 8=9600 9=19200 default
BYTDLY: DB 5 ;0=0 delay 1=10 ms 5=50 ms 9=90 ms 108H
;default time to send character in ter-
;minal mode file transfer for slow BBS.
CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms 9=900 ms 109H
;default time for extra wait after CRLF
;in terminal mode file transfer
NOOFCOL: DB 5 ;number of DIR columns shown 10AH
SETUPTST: DB YES ;yes=user-added Setup routine 10BH
SCRNTEST: DB YES ;Cursor control routine 10CH
NORETRY DB NO ;yes=DON'T ALLOW RETRY/QUIT OPTION 10DH
;no=ALLOW RETRY/QUIT AFTER 10 TIMEOUTS
BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
CRCDFLT: DB YES ;yes=default to CRC checking 10FH
TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
CONVBKSP: DB NO ;yes=convert backspace to rub 111H
TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H
ADDLF: DB NO ;no=no LF after CR to send file in 113H
;terminal mode (added by remote echo)
TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
TRANLOGON: DB NO ;yes=allow transmission of logon 115H
;write logon sequence at location LOGON
SAVCCP: DB YES ;yes=do not overwrite CCP 116H
LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
;no=external command if EXTCHR precedes
TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
LSTTST: DB YES ;yes=printer available on printer port 119H
XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH
;sending a file in terminal mode
XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
;sending a file in terminal mode
TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
EXTRA1: DB 0 ;for future expansion 11EH
EXTRA2: DB 0 ;for future expansion 11FH
BRKCHR: DB '@'-40H ;^@ = Send 300 ms. break tone 120H
NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
LOGCHR: DB 'L'-40H ;^L = Send logon 122H
LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
EXTCHR: DB '^'-40H ;^^ = Send next character 127H
;
;
DS 2 ; 128H
;
IN$MODCTL1: IN MODCTL1 ! RET ;in modem control port 12AH
DS 7
OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H
DS 7
IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH
DS 7
maskr: ani 2
ret
testr: cpi 2
ret
masks: ani 1
ret
tests: cpi 1
ret
ds 12
DS 2 ; 160H
DS 6 ; 162H
JMP$GOODBYE: JMP GOODBYE ; 168H
JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
JMP$NEWBAUD: JMP NEWBAUD ;change baudrate 16EH
RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
JMP$SETUPR: JMP SETUPR ; 177H
DS 3 ; 17AH
JMP$SYSVER: JMP SYSVER ; 17DH
JMP$BREAK: JMP SENDBRK ; 180H
;
;
; Do not change the following six lines.
;
JMP$ILPRT: DS 3 ; 183H
JMP$INBUF DS 3 ; 186H
JMP$INLNCOMP: DS 3 ; 189H
JMP$INMODEM DS 3 ; 18CH
JMP$NXTSCRN: DS 3 ; 18FH
JMP$TIMER DS 3 ; 192H
;
;
; routine to clear to end of screen.
;
CLREOS: LXI D,EOSMSG
MVI C,PRINT
CALL MEX
RET
;
CLRSCRN: LXI D,CLSMSG
MVI C,PRINT
CALL MEX
RET
;
SYSVER: MVI C,ILP
call mex
DB 'Version for Heath/ZDS 100 Series Computers'
DB CR,LF
DB ' with the U.S. Robotics S-100 modem.'
IF SWEPU
DB CR,LF
DB 'Swedish type pulse dialing.'
ENDIF
DB CR,LF,0
RET
;
;.....
;
;
; The following routine sends a break "character" to the remote
; computer for 300 ms. The "MSPEED" value is needed to decide whether
; the modem is at 150, 300, 600, or 1200 baud. The routine must know
; this because U.S.R. set up the RTS bit of the command resgister as a
; baud rate selection bit. Note that the "MVI A, 01FH" does not change
; any flags.
;
SENDBRK: LDA MSPEED ; Get speed byte
CPI 1 ; Are we at 150 baud?
MVI A, 01FH ; Set up for 150/600 (no flag changes)
JZ SBRK2 ; And if we are, go do that
LDA MSPEED ; Get speed byte
CPI 3 ; Are we at 600 baud?
MVI A, 01FH ; Set up for 150/600
JZ SBRK2
MVI A, 03FH ; Otherwise, set up for 300/1200
SBRK2: OUT MODCTL1 ; Send break
MVI B, 3 ; 300 ms delay value
MVI C,TIMER
CALL MEX ; Wait that long
JMP INITMOD1 ; Restore USRT
;.....
;
;
; The U.S.R. S-100 does not have a "quick-disconnect" feature like
; the Hayes does (by lowering DTR). Therefore, "GOODBYE" is not
; implemented except to check if modem is connected. Control-N still
; works to hang up (see note above in introduction)
;
GOODBYE: IN MODCTL1 ;CHECK IF CARRIER
ANI MODDCDB
RZ
MVI B,10 ;WAIT 1 SECOND
MVI C,TIMER
CALL MEX
IN MODCTL1 ;CHECK IF STILL CARRIER
ANI MODDCDB
RZ
CALL DISCFAIL
RET
;.....
;
;
; You can use this area for any special initialization or setup you may
; wish to include. Each must stop with a RET. This initialization
; sets up 300 baud, 8 data bits, 1 stop bit, no parity. Due to a
; quirk in the U.S.R. S-100 (it seems to have plenty of 'em), after
; you change baud rates, you should send an "AT" followed by a
; carriage return. Therefore, this is done after every initialization
; when there is no carrier present.
;
;
; NOTE: The U.S.R. S-100 does not operate too well at clock speeds
; over 4 MHz. As we are running at that speed or higher, the
; lines with XCHG have been inserted. These serve as time wasting
; routines to let the U.S.R. S-100 catch up. This is not a
; problem when doing character I/O, as the program checks to see
; if the modem is ready to accept a character.
;
;
INITMOD: LDA MSPEED ; Get the default baude rate
CPI 0 ; Is it 150 baud?
JZ OK150 ; If so set up for 150 baud
CPI 1 ; Is it 300 baud?
JZ OK300 ; If so set up for 300 baud
CPI 3 ; Is it 600 baud?
JZ OK600
CPI 5 ; Is it 1200 baud?
JZ OK1200
MVI C,ILP
CALL MEX ; Tell user if not valid
DB '++ Incorrect default baud rate ++',CR,LF,BELL,0
INITMOD1: XRA A ; Zero accumulator
OUT MODCTL1 ; Clear 8251A
XCHG ; For fast systems
XCHG ; For fast systems
OUT MODCTL1 ; Twice
XCHG ; For fast systems
XCHG ; For fast systems
OUT MODCTL1 ; Three times, even
XCHG ; For fast systems
XCHG ; For fast systems
MVI A, 040H ; Reset UART command
OUT MODCTL1
XCHG ; For fast systems
XCHG ; For fast systems
MODEBT: MVI A, 04FH ; 8 bits, 1 stop, no parity
OUT MODCTL1
XCHG ; For fast systems
XCHG ; For fast systems
CMDBT: MVI A, 037H ; On hook, Tx/Rx enable, reset errs
OUT MODCTL1
XCHG ; For fast systems
XCHG ; For fast systems
BDCODE: MVI A, 1 ; 300 baud code
STA MSPEED
IN MODCTL1 ; Get the current status
ANI MODDCDB ; See if there is a carrier
RNZ ; If so, don't do AT stuff
MVI B, 1 ; 100 ms
MVI C,TIMER
CALL MEX ; Wait that long
LXI H,RESETST ; Point to resetstring
CALL SMSEND ; Reset modem
MVI B, 5 ; 500 ms
MVI C,TIMER
CALL MEX ; Wait that long
LXI H,INITST ; Point to initstring
CALL SMSEND ; Initialize command status
RET
;
RESETST:DB 'ATZ',CR,0 ; Reset modem command status
INITST: DB 'ATS0=0S7=45E1',CR,0 ; Don't answer, wait 45 s for carrier
;
; This routine is used to set up for a new baud rate
; which on the U.S.R. can be 150, 300, 600, or 1200.
; This modem does not have a provision for the MEX
; 110 rate and the U.S.R. 150 baud possibility is
; therefore utilized. You should not exepect 150 baud
; to work unless modems at both ends are set up for
; this same baud rate.
;
;
SETUPR: MVI C,SBLANK ;Any arguments?
CALL MEX
JC TELL ;If not, go display baud
LXI D,CMDTBL
MVI C,LOOKUP
CALL MEX ;Parse argument
PUSH H ;Save any parsed argument addrs on stack
RNC ;If we have one, return to it
POP H ;Oops, input not found in table
MVI C,ILP
CALL MEX ;Tell user input not valid
DB CR,LF,'Only 150, 300, 600 or 1200 allowed by SET',CR,LF,0
RET
;
CMDTBL: DB '15','0'+80H
DW OK150
DB '30','0'+80H
DW OK300
DB '60','0'+80H
DW OK600
DB '120','0'+80H
DW OK1200
DB 0
;
TELL: MVI C,ILP
CALL MEX ;Print current baud rate
DB CR,LF,'Baud rate is now: ',0
LDA MSPEED
MVI C,PRBAUD
CALL MEX
RET
;
;
OK150: MVI A,0 ;MSPEED 150
LHLD BD150 ;Get 150 baud values in (HL)
JMP LOADBD ;Go load them
OK300: MVI A,1 ;MSPEED 300
LHLD BD300 ;Get 300 baud values in (HL)
JMP LOADBD ;Go load them
OK600: MVI A,3 ;MSPEED 600
LHLD BD600 ;Get 600 baud values in (HL)
JMP LOADBD ;Go load them
OK1200: MVI A,5 ;MSPEED 1200
LHLD BD1200 ;Get 1200 baud values in (HL)
JMP LOADBD ;Go load them
;
LOADBD: STA BDCODE + 1 ; Change baud rate code value
MOV A,L ; Get mode byte value
STA MODEBT + 1 ; Change mode byte
MOV A,H ; Get cmd byte
STA CMDBT + 1 ; Change cmd byte
JMP INITMOD1 ; (Re)initialize modem
;
NEWBAUD: CPI 0
JZ OK150
CPI 1
JZ OK300
CPI 3
JZ OK600
CPI 5
JZ OK1200
RET
;
; Baud Rate Table
;
BD150 DW 274FH ;150 baud
BD300 DW 374FH ;300 baud
BD600 DW 274EH ;600 baud
BD1200 DW 374EH ;1200 baud
; __--
; \ \___ Mode Byte to select baud rate (4E or 4F)
; \_____ Command Byte to select speed (27 or 37)
;
BAUDBUF: DB 10, 0
DS 10
;
;
;
;
EOSMSG: DB ESC,'J',0,0,0,'$'
CLSMSG: DB ESC,'E',0,0,0,'$'
;
;
;
;
; This is the DIAL routine called by MEX to dial a digit. The digit
; to be dialed is passed in the A register. Note that two special
; codes must be intercepted as non-digits: 254 (start dial sequence)
; and 255 (end-dial sequence). Mex will always call DIAL with 254
; in the accumulator prior to dialing a number. Mex will also call
; dial with 255 in A as an indication that dialing is complete. Thus,
; the overlay may use these values to "block" the number, holding it
; in a buffer until it is completely assembled (in fact, that's the
; scheme employed here for the Smartmodem).
;
; After the 254-start-dial sequence, MEX will call the overlay with
; digits, one-at-a-time. Except as noted below, MEX will make no
; assumptions about the digits, and will send each to the DIAL routine
; un-inspected (some modems, like the Smartmodem, allow special
; non-numeric characters in the phone number, and MEX may make
; no assumptions about these).
;
; If SWEPU is set true MEX will modify numbers (0 to 9) to correct
; the number of pulses sent to the telephone switching equipment.
; Note that letters will not be modified and and should not be used
; with this special type of pulse dialing.
;
; After receiving the end-dial sequence (255) the overlay must take
; whatever end-of-dial actions are necessary *including* waiting for
; carrier at the distant end. The overlay should monitor the keyboard
; during this wait (using the MEX keystat service call), and return
; an exit code to MEX in the A register, as follows:
;
; 0 - Carrier detected, connection established
; 1 - Far end busy (only for modems that can detect this condition)
; 2 - No answer (or timed out waiting for modem response)
; 3 - Keyboard abort (^C only: all others should be ignored)
; 4 - Error reported by modem
; 5 - No ring
; 6 - No dialtone
;
; <No other codes should be returned after an end-dial sequence>
;
; The overlay should not loop forever in the carrier-wait routine, but
; instead use either the overlay timer vector, or the INMDMV (timed 100
; ms character wait) service call routine.
;
; The DIAL routine is free to use any of the registers, but must return
; the above code after an end-dial sequence
;
;
DIAL: LHLD DIALPT ;FETCH POINTER
CPI 254 ;START DIAL?
JZ STDIAL ;JUMP IF SO
CPI 255 ;END DIAL?
JZ ENDIAL ;JUMP IF SO
;
; Not start or end sequence, must be a digit to be sent to the modem
;
IF SWEPU
CALL CKDIG
NOMOD: MOV M,A ;PUT CHAR IN BUFFER
INX H ;ADVANCE POINTER
SHLD DIALPT ;STUFF PNTR
RET ;ALL DONE
CKDIG: CPI '9' + 1 ;0 TO 9 IS THE RANGE TO ADJUST
RNC ;TOO LARGE
MOV C,A ;SAVE THE NUMBER
SUI '0'
MOV A,C ;RECOVER IT
RC ;TOO SMALL
CPI '9' ;9 CORRESPONDS TO ZERO
JZ ZERO
ADI 1 ;ADD ONE PULSE TO ALL FROM 0 TO 8
RET
ZERO: MVI A,'0'
RET
ENDIF
;
IF NOT SWEPU
MOV M,A ;PUT CHAR IN BUFFER
INX H ;ADVANCE POINTER
SHLD DIALPT ;STUFF PNTR
RET ;ALL DONE
ENDIF
;
; Here on a start-dial sequence
;
STDIAL: LXI H,DIALBF ;SET UP BUFFER POINTER
SHLD DIALPT
IF SWEPU
MVI A,'P' ;FORCE PULSE DIALING
STA TPULSE
ENDIF
RET
;
; Here on an end-dial sequence
;
ENDIAL: MVI M,CR ;STUFF END-OF-LINE INTO BUFFER
INX H ;FOLLOWED BY TERMINATOR
MVI M,0
LDA TPULSE ;GET OVERLAY'S TOUCH-TONE FLAG
STA SMDIAL+3 ;PUT INTO STRING
LXI H,SMDIAL ;POINT TO DIALING STRING
CALL SMSEND ;SEND IT
WAITSM: MVI C,INMDM
CALL MEX ;CATCH ANY OUTPUT FROM THE MODEM
JNC WAITSM ;LOOP UNTIL NO MORE CHARACTERS
;
; THE FOLLOWING LOOP WAITS FOR A RESULT FROM THE MODEM (UP TO
; 75 SECONDS. YOU MAY CHANGE THIS VALUE IN THE FOLLOWING LINE).
; NOTE THAT THE SMARTMODEM HAS AN INTERNAL 30 SECOND TIMEOUT WHILE
; FOR A CARRIER ON THE OTHER END. YOU CAN CHANGE BY PLAYING WITH THE
; S7 VARIABLE (I.E. SEND THE SMARTMODEM "AT S7=20" TO LOWER THE 30 SECOND
; WAIT TO 20 SECONDS).
;
RESULT: MVI C,75 ;<<== MAXIMUM TIME TO WAIT FOR RESULT
SMWLP: PUSH B
MVI B,1 ;CHECK FOR A CHAR, UP TO 1 SEC WAIT
MVI C,TMDINP ;DO TIMED INPUT
CALL MEX
POP B
JNC SMTEST ;JUMP IF MODEM HAD A CHAR
PUSH B ;NO, TEST FOR CONTROL-C FROM CONSOLE
MVI C,CHEKCC
CALL MEX
POP B
JNZ SMNEXT ;IF NOT, JUMP
MVI B,CR ;YES, SHUT DOWN THE MODEM
MVI C,SNDCHR
CALL MEX
MVI A,3 ;RETURN ABORT CODE
RET
SMNEXT: DCR C ;NO
JNZ SMWLP ;CONTINUE
;
; 75 SECONDS WITH NO MODEM RESPONSE (OR NO CONNECTION)
;
SMTIMO: MVI A,2 ;RETURN TIMEOUT CODE
RET
;
; MODEM GAVE US A RESULT, CHECK IT
;
SMTEST: ANI 7FH ;IGNORE ANY PARITY
CALL SMANAL ;TEST THE RESULT
MOV A,B ;A=RESULT (CY SIGNIFICANT HERE TOO)
PUSH PSW ;SAVE IT
SMTLP: MVI C,INMDM ;FLUSH ANY REMAINING COMMAND LINE
CALL MEX
JC SMCHEK ;JUMP IF NO INPUT
CPI LF ;GOT SOME ... WAITING FOR EOL
JNZ SMTLP ;EAT ANY IN-BETWEEN
SMCHEK: POP PSW ;A HAS MEX RETURN-CODE, CY=1 IF UNKNOWN
JC RESULT ;IF RESULT UNKNOWN, IGNORE IT
RET
;
SMANAL: MVI B,0 ;PREP CONNECT CODE
CPI 'C' ;"CONNECT"?
RZ
MVI B,2 ;PREP NO CONNECT MSG B=2
CPI 'N' ;N=NO CONNECT
RZ
MVI B,4 ;PREP ERROR MSG B=4
CPI 'E' ;E=ERROR
RZ
STC ;UNKNOWN...
RET
;
; FOLLOWING ROUTINE DISCONNECTS THE MODEM USING SMARTMODEM
; CODES. ALL REGISTERS ARE AVAILABLE FOR THIS FUNCTION.
; RESULT IS RETURNED TO USER.
;
;
DISCON: MVI B,10
MVI C,TIMER ;WAIT 1 SECONDS
CALL MEX
LXI H,SMATN ;SEND '+++'
CALL SMSEND
MVI B,30 ;WAIT 3 MORE SECONDS
MVI C,TIMER
CALL MEX
IN MODCTL1 ;CHECK IF CARRIER
ANI MODDCDB
JZ DISCOK
MVI B,30 ;WAIT ANOTHER 3 SECONDS
MVI C,TIMER
CALL MEX
IN MODCTL1 ;CHECK IF STILL CARRIER
ANI MODDCDB
JNZ DISCFAIL ;IF STILL CARRIER TELL USER
DISCOK: MVI C,ILP
CALL MEX
DB CR,LF,'++DISCONNECTED++',CR,LF,0
RET
DISCFAIL:
MVI C,ILP
CALL MEX
DB CR,LF,'+++ WARNING !!! NOT DISCONNECTED +++',CR,LF,0
RET
;
SMATN: DB '+++',0
;
; SMARTMODEM UTILITY ROUTINE: SEND STRING TO MODEM
;
SMSEND: MVI C,SNDRDY ;WAIT FOR MODEM READY
CALL MEX
JNZ SMSEND
MOV A,M ;FETCH NEXT CHARACTER
INX H
ORA A ;END?
RZ ;DONE IF SO
MOV B,A ;NO, POSITION FOR SENDING
MVI C,SNDCHR ;NOPE, SEND THE CHARACTER
CALL MEX
JMP SMSEND
;
; DATA AREA
;
SMDIAL: DB 'ATDT, '
DIALBF: DS 52 ;2* 24 CHAR MAX, + CR + NULL + SLOP
DIALPT: DS 2 ;DIAL POSITION POINTER
;
END