home *** CD-ROM | disk | FTP | other *** search
/ CP/M / CPM_CDROM.iso / cpm / modems / modem / usr-v32.lbr / USR-V32.IZF / USR-V32.INF
Text File  |  1988-11-20  |  8KB  |  184 lines

  1.                            Courier V.32 modem
  2.  
  3.      The Courier V.32 modem uses state-of-the-art modem chip technology
  4. to bring a cost-effective, easy-to-use data communications solution to
  5. users requiring true full-duplex or international standard operation.
  6.  
  7.      In addition to CCITT V.32 capability, the Courier V.32 provides
  8. full CCITT and Bell standards compatibility at 2400, 1200 and 300 bps,
  9. with industry-standard MNP Class 1 through 5 error control and data
  10. compression, increasing error-free throughput up to 80 percent.
  11.  
  12.      Courier V.32 is designed for applications requiring true
  13. full-duplex and/or synchronous transmission at high speeds.  These
  14. applications include host-to-host or micro-to-mainframe communication,
  15. remote LAN bridging, dedicated leased line service, leased line dial
  16. backup and situations requiring high-speed international standards
  17. compatibility.
  18.  
  19.      The Courier V.32 provides asynchronous or synchronous transmission
  20. on dial-up or two-wireleased lines.  Its synchronous capability is
  21. available at all speeds except 300 bps.
  22.  
  23.      While most synchronous modems offer no auto-dialing capability, the
  24. Courier V.32 modem provides a synchronous auto-dialing capability, in
  25. which the modem automatically dials a phone number stored in nonvolatile
  26. RAM, then establishes a synchronous data link.
  27.  
  28.      For asynchronous operations, Courier V.32 uses the
  29. industry-standard "AT" auto-dialing command set for compatibility with
  30. all micro-computer data communications software.
  31.  
  32.      The Courier V.32 fully conforms to CCITT's V.32 data-signalling
  33. specifications.  It simultaneously operates high-speed "send" and
  34. "receive" frequencies using trellis-coded modulation and
  35. echo-cancelling.  These advanced technologies keep Courier V.32 online
  36. and error-free under even the harshest telephone network conditions.
  37.  
  38.      U.S. Robotics offers the Courier V.32 modem in external and
  39. rackmounted models.  The rackmounted version is designed for use in U.S.
  40. Robotics Rackmount 30 Modular Modem System, which includes a
  41. 19-inch-wide chassis housing up to 15 modem and interface boards along
  42. with two 140-watt power supplies.
  43.  
  44.      The Courier V.32 carries USRUs standard two-year parts and service
  45. warranty, extendable for $20.50 per year.
  46.  
  47.  
  48. DESCRIPTION
  49.  
  50. Transmits/Receives at 9600, 7200, 4800,  2400, 1200 and 300 bps.
  51.  
  52. Data Compression MNP Service Class 5 compression, available at all
  53. transmission speeds above 300 bps, increases effective throughput by up
  54. to 80 percent.  Maximum effective throughput is 17,400 bps.
  55.  
  56. Error Checking MNP Service Classes 1 through 4 at all speeds above 300
  57. bps.
  58.  
  59. Hardware/software flow control allows fixed RS-232 rates up to 19.2
  60. Kbps.
  61.  
  62. Asynchronous or synchronous transmission on dial-up or leased lines.
  63. Synchronous available at all speeds >300 bps.
  64.  
  65. Auto-dial, auto-answer "AT" command auto-dialing in asynchronous mode.
  66. Synchronous auto-dialing of phone number stored in RAM.
  67.  
  68. Ease of Use Features:
  69.  
  70. Automatic transmission-speed adjustment, in V.32 mode, falls back from
  71. 9600 to 7200 or 4800 bps, guaranteeing highest possible speed under  a
  72. wide range of conditions.
  73.  
  74. Automatically adapts to the highest data rate supported by the remote
  75. modem.
  76.  
  77. Speaker with volume control for audio call-progress monitoring.
  78. On-screen and bottom label help summaries.
  79.  
  80. RS232-C pins 2 and 3 (Send and Receive data) switch-reversible for easy
  81. use with terminal, computer or printer.
  82.  
  83. Technical Specs:
  84.  
  85. Twelve LED front panel indicators.
  86. Local analog and digital loopback, and remote digital loopback self-testing.
  87. U.S./CCITT answer sequences.
  88. Includes power adapter and RJ11C phone cord.
  89. Two phone jacks for voice/data communications.
  90. Size: 8.3" wide, 12.65" deep, 1.57" tall.
  91. Power consumption: 10 watts
  92. Power adapter UL listed, CSA approved.  Supply voltage:
  93.      115 VAC, 60 Hz, 16 VAC output.
  94. Receive sensitivity -43 dBm.  Transmit level -9 dBm.
  95.  
  96.  
  97. SPECIAL FEATURES
  98.  
  99.      High-Speed Operation V.32 capability provides 9600, 7200 and 4800
  100. bps data transmission.
  101.  
  102.      Trellis-coded modulation delivers maximum immunity to a variety of
  103. line conditions and impairments.
  104.  
  105.      Symmetrical full-duplex operation yields fastest possible round
  106. trip response time.
  107.  
  108.      Courier V.32 is well suited to all data communications
  109. applications, including high-speed file transfer, interactive two-way
  110. communications, micro-to-mainframe synchronous communications,
  111. synchronous LAN bridging, dedicated leased lines and leased line dial
  112. backup.
  113.  
  114.      Nonvolatile Random Access Memory (NRAM)  Easily programmable
  115. nonvolatile memory stores user-defined default configuration.
  116.  
  117.      Phone Number Storage Creates auto dial directory of four frequently
  118. called phone numbers.
  119.  
  120.      Automatic Dialing "AT" command dialing and automatic dialing of
  121. stored phone number at power on, reset command or when terminal turns on
  122. DTR.
  123.  
  124.      Synchronous Auto-Dialing Automatically dials stored phone number,
  125. then establishes synchronous data link.
  126.  
  127.      Diagnostics =  Local and remote loopback testing provides DTE,
  128. modem and phone line diagnostic capabilities.
  129.  
  130.  
  131. COMPATIBILITY
  132.  
  133. CCITT V.32-compatible at 9600, 7200 and 4800 bps.
  134. CCITT V.22 bis-compatible at 2400 bps.
  135. CCITT V.22- and Bell 212A-compatible at 1200 bps.
  136. CCITT V.21- and Bell 103-compatible at 300 bps.
  137. Uses "AT" auto-dial command set in asynchronous mode.
  138. CCITT V.42-compatible (MNP Class 1-4 error control).
  139. MNP Class 5 data compression.
  140. FCC, DOC certified.
  141.  
  142.  
  143. A WORD ABOUT U.S. ROBOTICS
  144.  
  145.  
  146.      When you purchase a modem, you buy more than data communications
  147. hardware.  When you purchase a modem, you buy a relationship with an
  148. organization.  To help in your evaluation, I would like to introduce us
  149. to you.
  150.  
  151.      We are U.S. Robotics.  We are more than 175 people dedicated to
  152. designing, manufacturing and providing quality products, services and
  153. systems to enhance the capabilities of business and professional
  154. customers worldwide.  Our mission is to strive to be "the best data
  155. communications company."
  156.  
  157.      Since our start in 1976, we have sold more than one million modems,
  158. and led the industry with many technological firsts.  For example, we
  159. built the first modem using off-the-shelf microprocessor technology
  160. (1982), and the first surface-mount-technology modem (1987).  Over the
  161. years, we have honed our quality control and manufacturing capabilities
  162. by making modems for Apple, Commodore, Zenith, Kaypro, and Grid.  This
  163. is reflected in our own Courier and Sportster products.  For three out
  164. of four years, we have made the INC. 500 list of fastest growing private
  165. firms.
  166.  
  167.      I know you have a modem choice.  As you will discover, the
  168. difference between vendors is partially technological Q Data
  169. Communications magazine rated our Courier HST as the #1 high-speed
  170. modem (April 1988).  Part of it is the way the vendor relates to its
  171. customers.  USR was ranked as the #1 overall performing modem vendor by
  172. modem users surveyed by Datapro Research (October 1988).
  173.  
  174.      We are proud of our accomplishments and of the service we provide
  175. to our customers.  Thank you for considering U.S. Robotics products.  I
  176. believe we have much to offer, and we look forward to satisfying your
  177. data communications needs.
  178.  
  179.  
  180.      Sincerely yours,
  181.  