; M7MOL-2.ASM -- Overlay file for MOLECULAR SuperMicro series.
;
; Use the "SET" command to change baudrate when desired.
;
; Edit this file for your preferences then follow the "TO USE:" example
; shown below.
;
;
; TO USE: First edit this file filling in answers for your own
; equipment. Then assemble with ASM.COM or equivalent
; assembler. Then use DDT to overlay the the results
; of this program to the original .COM file:
;
; A>DDT MDM7xx.COM
; DDT VERS 2.2
; NEXT PC
; 4x00 0100
; -IM7MOL-2.HEX (note the "I" command)
; -R ("R" loads in the .HEX file)
; NEXT PC
; 4x00 0000
; -G0 (return to CP/M)
; A>SAVE 73 MDM7xx.COM (now have a modified .COM file)
; ^
; May vary depending upon version of MDM7xx
;
; = = = = = = = = = = = = = = = = = =
;
; 04/30/84 - Renamed and revised for MDM7xx.COM - Dennis Recla
; 12/07/83 - Revised for MOLECULAR SuperMicros - Gene Head
;
; = = = = = = = = = = = = = = = = =
;
BELL: EQU 07H ;bell
CR: EQU 0DH ;carriage return
ESC: EQU 1BH ;escape
LF: EQU 0AH ;linefeed
;
YES: EQU 0FFH
NO: EQU 0
;
;
; Change the value at MODDATP if it does not match what you are using.
;
MODDATP: EQU 062H ;data port for Multi I/O
MODCTL1: EQU MODDATP+1 ;status port for Multi I/O
MODCTL2: EQU 31H ;speed control port
MODRCVB: EQU 1H ;bit to test for received data
MODRCVR: EQU 1H ;modem receive ready
MODSNDB: EQU 4H ;bit to test for ready to send
MODSNDR: EQU 4H ;modem send ready bit
;
;
ORG 100H
;
; Change the clock speed if needed, to match your system
;
DS 3 ;(for "JMP START" instruction)
;
PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
SMARTMODEM: DB NO ;yes=HAYES Smartmodem, no=non-Hayes 104H
TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H
;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED: DB 5 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
;6=2400 7=4800 8=9600 9=19200 default
BYTDLY: DB 9 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
;default time to send character in ter-
;minal mode file transfer for slow BBS.
CRDLY: DB 9 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
;default time for extra wait after CRLF
;in terminal mode file transfer
NOOFCOL: DB 5 ;number of DIR columns shown 10AH
SETUPTST: DB YES ;yes=user-added Setup routine 10BH
SCRNTEST: DB NO ;Cursor control routine 10CH
ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH
;no=resend a record after a valid NAK
BAKUPBYTE: DB YES ;yes=change any file same name to .BAK 10EH
CRCDFLT: DB YES ;yes=default to CRC checking 10FH
TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
CONVBKSP: DB NO ;yes=convert backspace to rub 111H
TOGGLEBK: DB NO ;yes=allow toggling of bksp to rub 112H
ADDLF: DB NO ;no=no LF after CR to send file in 113H
;terminal mode (added by remote echo)
TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
TRANLOGON: DB YES ;yes=allow transmission of logon 115H
;write logon sequence at location LOGON
SAVCCP: DB YES ;yes=do not overwrite CCP 116H
LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
;no=external command if EXTCHR precedes
TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
LSTTST: DB YES ;yes=allow toggling of printer on/off 119H
XOFFTST: DB YES ;yes=checks for XOFF from remote while 11AH
;sending a file in terminal mode
XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
;sending a file in terminal mode
TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
IGNORCTL: DB NO ;yes=CTL-chars above ^M not displayed 11DH
EXTRA1: DB 0 ;for future expansion 11EH
EXTRA2: DB 0 ;for future expansion 11FH
BRKCHR: DB '@'-40H ;^@ = Send a 300 ms. break tone 120H
NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
LOGCHR: DB 'L'-40H ;^L = Send logon 122H
LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
EXTCHR: DB '^'-40H ;^^ = Send next character 127H
;
;
DS 2 ; 128H
;
IN$MODCTL1: IN MODCTL1 ! RET ;in modem control port 12AH
DS 7
OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H
DS 7
IN$MODDATP: IN MODDATP ! RET ;input modem data port 13EH
DS 7
ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H
CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH
ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH
CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H
DS 12 ;PMMI only calls 154H
;
;
LOGONPTR: DW LOGON ;for user message. 160H
DS 6 ; 162H
JMP$GOODBYE: JMP GOODBYE ; 168H
JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
DS 9 ; 16EH
JMP$SETUPR: JMP SETUPR ; 177H
JMP$SPCLMENU: JMP SPCLMENU ; 17AH
JMP$SYSVER: JMP SYSVER ; 17DH
JMP$BREAK: JMP SENDBRK ; 180H
;
;
; Do not change the following six lines.
;
JMP$ILPRT: DS 3 ; 183H
JMP$INBUF DS 3 ; 186H
JMP$INLNCOMP: DS 3 ; 189H
JMP$INMODEM DS 3 ; 18CH
JMP$NXTSCRN: DS 3 ; 18FH
JMP$TIMER DS 3 ; 192H
;
;
; The following clear the screen for the H19 terminal
;
CLREOS: CALL JMP$ILPRT ; 195H
DB ESC,'J',0,0,0 ; 198H
RET ; 19DH
;
CLRSCRN: CALL JMP$ILPRT ; 19EH
DB ESC,'E',0,0,0 ; 1A1H
RET ; 1A6H
;
;
SYSVER: CALL JMP$ILPRT ; 1A7H
DB 'For Molecular Super Micro'
DB CR,LF
DB 'List Device must not be set to local'
DB CR,LF,0
RET
;.....
;
;
;-----------------------------------------------------------------------
;
; NOTE: You can change the SYSVER message to be longer or shorter. The
; end of your last routine should terminate by 0400H (601 bytes
; available after start of SYSVER) if using the Hayes Smartmodem
; or by address 0C00H (2659 bytes) otherwise.
;
;-----------------------------------------------------------------------
;
; You can put in a message at this location which can be called up with
; CTL-L if TRANLOGON has been set TRUE. You can put in several lines if
; desired. End with a 0.
;
LOGON: DB 0
;.....
;
;
; This routine sends a 300 ms. break tone to reset some time-share
; computers.
;
SENDBRK: MVI A,15H
OUT MODCTL1
MVI A,7FH
OUT MODCTL1
LXI B,300H
BREAK0: MVI A,0DCH
BREAK1: DCR A
NOP
JNZ BREAK1
DCX B
MOV A,B
ORA C
JNZ BREAK0
MVI A,15H
OUT MODCTL1
MVI A,6FH
OUT MODCTL1
RET
;.....
;
;
; This routine sends a 300 ms. break tgone and set DTR low for the same
; length of time to disconnect some modems such as the Bell 212A, etc.
;
GOODBYE: RET
;.....
;
;
; The following is used to initialize the Multi I/O 8250 port
;
INITMOD: MVI A,1 ;select write register one
OUT MODCTL1
XRA A ;turn off interupts
OUT MODCTL1
MVI A,4 ;select write register 4
OUT MODCTL1
MVI A,44H ;select 8 bit xsfr
OUT MODCTL1
MVI A,3 ;select write register 3
OUT MODCTL1
MVI A,0C1H ;8-bit receive - receive enable
OUT MODCTL1
MVI A,5 ;select write register 5
OUT MODCTL1
MVI A,0EAH ;8-bit transmit -transmit enable
OUT MODCTL1
MVI A,10H ;reset interupts - select register 0
OUT MODCTL1
RET
;
;
; The following routine changes the baud rate for the Multi I/O with the SET
; command.
;
SETUPR: LXI D,BAUDBUF ;point to input buffer for INLNCOMP
CALL JMP$ILPRT
DB 'Input Baud Rate (300, 1200, 2400, 4800, 9600): ',0
CALL JMP$INBUF
LXI D,BAUDBUF+2
CALL JMP$INLNCOMP ;compare BAUDBUF+2 with characters below
DB '300',0
LXI H,BD300
JNC LOADBD ;go if got match
CALL JMP$INLNCOMP
DB '1200',0
LXI H,BD1200
JNC LOADBD
CALL JMP$INLNCOMP ;compare BAUDBUF+2 with characters below
DB '2400',0
LXI H,BD2400
JNC LOADBD ;go if got match
CALL JMP$INLNCOMP ;compare BAUDBUF+2 with characters below
DB '4800',0
LXI H,BD4800
JNC LOADBD ;go if got match
CALL JMP$INLNCOMP
DB '9600',0
LXI H,BD9600
JNC LOADBD
CALL JMP$ILPRT ;all matches failed - tell operator
DB '++ Incorrect entry ++',CR,LF,BELL,0
JMP SETUPR ;try again
;
LOADBD: CALL INITMOD
MOV A,H
OUT MODCTL2
MOV A,L
OUT MODCTL2
RET
;
; Table of baud rate parameters
;
BD300: EQU 0734H
BD1200: EQU 4768H
BD2400: EQU 4734H
BD4800: EQU 471AH
BD9600: EQU 470DH
;
BAUDBUF: DB 10,0
DS 10
;-----------------------------------------------------------------------
;
; This routine can be used for your equipment, be sure to end with RET
; If using the Hayes Smartmodem this is unavailable without a special
; change.
;
SPCLMENU: RET
;
;-----------------------------------------------------------------------
; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
; 0C00H (without Smartmodem)
;