THE CALL STATEMENT
--------------------------------
There have been a number of requests for clarification of the
CALL statement in the various Microsoft langauges. Hopefully,
the following explanations will clear up several
misunderstandings.
First, let's look at the "Microsoft CALL standard". When any
Microsoft program issues a CALL statement, such as "CALL MYROUT",
control is passed to the address specified by MYROUT. In all
cases except the Basic Interpreter, MYROUT must be the name of a
SUBROUTINE program, or a GLOBAL/PUBLIC label within a Macro-80
routine. The calling and the called program must be linked
together by L80 into a single file.
In the Basic Interpreter (MBASIC), the variable MYROUT must be
set to the beginning address of the subroutine. If we complicate
things by adding a few paramaters to the CALL, such as: "CALL
MYROUT(A,B); the parameters are passed as follows. The
*ADDRESS* of the first parameter is passed in registers HL, the
second in DE, and the third in BC. If there are more than three
parameters, BC points to a block of memory containing the
*ADDRESS* of parameters three through N. Note that the address
and *NOT* the parameter itself is passed.
The arguments themselves correspond to the standard Microsoft
variable format, (2 bytes for an integer, 4 bytes for single
precision floating point, and 8 bytes for a double precision
floating point number) with two exceptions.
COBOL passes variables as they would appear to another COBOL
program (DISPLAY, COMP, or COMP-3).
Strings are also handled a bit differently. The address
pointed to by the register contains a three byte "string
descriptor". This string descriptor contains the length of the
string in byte one, and the address of the string in bytes two
and three. When passing strings, take care not to modify this
string descriptor, or unpredictable results will occur.
In all cases, it is the user's responsibility to ensure that
the arguments correspond *EXACTLY*, in both type and number.
Also, be sure to preserve *ALL* of the registers and use your own
local stack when you call Macro routines.
With the preliminaries out of the way, let's look at which
languages can call which other languages. In the following
table, "B" represents the Basic Interpreter (MBASIC), "BC" the
Basic Compiler (BASCOM), "F" the Fortran Compiler (F80), "C" the
Cobol Compiler, and "M" the Macro Assembler (M80). A "Y" in the
appropriate entry means that a CALL is possible.
CALLed Program
CALLing B BC F C M
Program +---+---+---+---+---+
B | | | | | Y |
BC | | | 1 | | Y |
F | | | Y | | Y |
C | | | 2 | Y | Y |
M | | | 3 | | Y |
+---+---+---+---+---+
Notes:
1 - When calling a FORTRAN routine from the Basic Compiler, only
one of the two languages may be used to perform I/O. When the
programs are linked, link the Basic program first, then search
BASLIB, then load the Fortran program, then search FORLIB. The
multiply defined global message may be ignored.
2 - When calling FORTRAN from COBOL, remember that the variable
types are different. Only COMP data items will be passed in such
a way that FORTRAN can deal with them without an ENCODE statement.
3 - While Macro-80 may not directly CALL Fortran subroutines, you
may make use of the routines in the FORTRAN Library. For more
information, see the Fortran Manual. Of course, from within M80,
you may initiate execution of any other .COM file by reading the
file and then jumping to the appropriate address.