home *** CD-ROM | disk | FTP | other *** search
/ Hacker Chronicles 2 / HACKER2.BIN / 025.SB043.DOC < prev    next >
Text File  |  1993-04-19  |  926b  |  28 lines

  1.  
  2. SB-043
  3.  
  4. TS-520S -6v Supply Failure                8-9-79
  5.  
  6.  
  7. When troubleshooting a TS-520S, check all power supply voltages, including
  8. the -6v DC supply.  Symptoms such as dead, blown 2A DC fuse and now dead,
  9. low RX, no TX, or similar may occur after switching between 80 and 40M.
  10.  
  11. Cause of failure may be traced to an intermittent shorting between the 14v
  12. dc and -6 dc supplies as the band switch is rotated between 40 and 80
  13. meters.  This will weaken or destroy D8, a 6v zener on the FIX CH AVR unit.
  14. To prevent repeat failures, break the White lead and install a 22 K ohm 1/2
  15. watt resistor at the bandswitch S5-6, between the -6v supply line and
  16. switch terminal.  An of course replace D8 on the FIX CH AVR unit, X43-1100-
  17. 00
  18.  
  19. New Part:  22 k ohm 1/2 W carbon resistor
  20.  
  21. Please annotate your service manual.
  22.  
  23. JEB/yn
  24. (c) 8979TKC
  25.  
  26.  
  27. Downloaded From P-80 International Information Systems 304-744-2253
  28.