SB-050
TR-7600/7625 Optional Ceramic Filter 8-9-79
Adjacent channel rejection may be improved by changing one capacitor and
installing an optional narrow ceramic filter.
On the TX RX unit X44-1320-10, change:
* L41, CFG-455 F2 to CFL-455F
* C101, from 470pF to .001uF
Old part L41 L72-0309-05 CFT-455 F2
New part L41 L72-0306-05 CFL-455 F
Please annotate your service manual.
JEB/yn