TR-7625 Final Module Relpacement 3-20-80
When replacing the output hybrid with a "Red" Mitsubishi logo, and
additional 47pF cap must be installed between teh M57712H output terminal
and the RFO wrap post.
Install the M57712H with white silicone heatsink compound. Install a 47pF
as shown between the hybird output and the RFO terminal. Spread L21 as
necessary for at least 30W output at approximately 5.5 A total current
consumption.
Note: Hybirds not having a red mitsubishi logo do not require the
additional cap or adjustment.