home *** CD-ROM | disk | FTP | other *** search
/ Hacker Chronicles 2 / HACKER2.BIN / 050.SB820.DOC < prev    next >
Text File  |  1993-04-19  |  685b  |  25 lines

  1.  
  2. SB-820
  3.  
  4. TR-7625 Final Module Relpacement                        3-20-80
  5.  
  6.  
  7. When replacing the output hybrid with a "Red" Mitsubishi logo, and
  8. additional 47pF cap must be installed between teh M57712H output terminal
  9. and the RFO wrap post.
  10.  
  11. Install the M57712H with white silicone heatsink compound.  Install a 47pF
  12. as shown between the hybird output and the RFO terminal.  Spread L21 as
  13. necessary for at least 30W output at approximately 5.5 A total current
  14. consumption.
  15.  
  16. Note:  Hybirds not having a red mitsubishi logo do not require the
  17. additional cap or adjustment.
  18.  
  19.  
  20. JEB/yn
  21. (c) 32080TKC
  22.  
  23.  
  24. Downloaded From P-80 International Information Systems 304-744-2253