  1.  
  2.  
  3. SB-934
  4.  
  5. TM-221A Final Module Hints    4/11/89
  6.  
  7. When the Final module is replaced in a TM-221A, there is a
  8. possiblity that the transmit power will not go higher than
  9. 47 watts, even witht he APC turned OFF.  This is due to 
  10. variances in input impedance of Final Modules.  To correct
  11. this condition, an 8 pF capacitor can be added between the 
  12. input of the module and ground.  With some modules, a value
  13. between 8 pF and 15 pF will be required.  Try to choose a
  14. value as close to 8 pF as possible to prevent oscillation.
  15. The capacitor should be designated as C19 on the Final Unit
  16. (X45-1360-02).
  17.  
  18. Required Part
  19.  
  20. 8pF Ceramic Capacitor   Part # CC45CH1H080D
  21.  
  22. Alignment:
  23.  
  24. 1.    Turn the APC off (TX-RX unit VR-6: Clockwise).
  25.  
  26. 2.    Adjust TC3 TC4 (TX-RX) for maximum power supply current.
  27.     Since the APC is off, the Final will produce very high
  28.     power output.  It is important to perform this step as
  29.     quickly as possible.
  30.  
  31. 3.    Adjust the APC for 45 Watts.
  32.  
  33. This modification may be performed under warranty.
  34. Time required for this modification is 0.25 hrs or less.
  35. (c) 42888TKC