  12.                          BTU Heating/Cooling Analysis
  13.  
  14.  
  15.  
  16.  
  17.  
  18.  
  19.  
  20.  
  21.                                  Prepared by:
  22.  
  23.                                A to Z Unlimited
  24.                               901 Ferndale Blvd.
  25.                              High Point, NC 27262
  26.  
  27.  
  28.  
  29.  
  30.  
  31.  
  32.  
  33.                           Date Prepared: 08-29-1991
  34.  
  35.  
  36.  
  37.  
  38.  
  39.  
  40.  
  41.                                 Prepared for:
  42.  
  43.                                    John Doe
  44.                               1234 Anywhere Ct.
  45.                              High Point, NC 27260
  46.  
  47.                                  Page 1 of 3
  48.  
  49.                          BTU Heating/Cooling Analysis
  50.  
  51.    08-29-1991
  52.  
  53.    A to Z Unlimited
  54.    901 Ferndale Blvd.
  55.    High Point, NC 27262
  56.  
  57. ****************************************************************************
  58. ****************************************************************************
  59.  
  60.    This analysis prepared especially for: John Doe
  61.  
  62.    John Doe
  63.    1234 Anywhere Ct.
  64.    High Point, NC 27260
  65.  
  66.                           *********** HEATING ***********
  67.  
  68.        The heating outside design temperature is  10 degrees fahrenheit.
  69.        The heating  inside design temperature is  72 degrees fahrenheit.
  70.        The heating  temperature  differential is  62 degrees fahrenheit.
  71.  
  72.    The heat loss for this building is      77,790 BTU's.
  73.  
  74.    The heating unit must handle     883 CFM's for proper heating.
  75.  
  76.    The above figures include outside ventilation of     100 CFM's.
  77.  
  78.    Any heating unit must be rated as close as possible to the heat loss
  79.    calculated in this study, but not less than that amount.
  80.  
  81.    The above CFM allows an 80 degrees rise in inlet to outlet air temperature.
  82.  
  83.  
  84.                           *********** COOLING ***********
  85.  
  86.        The cooling outside design temperature is  95 degrees fahrenheit.
  87.        The cooling  inside design temperature is  72 degrees fahrenheit.
  88.        The cooling  temperature  differential is  23 degrees fahrenheit.
  89.  
  90.    The heat gain for this building is      47,465 BTU's.
  91.  
  92.           This translates into       4.0 tons of cooling.
  93.  
  94.    The preferred cooling CFM is   1,423 CFM's for proper cooling.
  95.  
  96.                  For high humidity areas use     1,186 CFM's
  97.                  For normal humidity areas use   1,423 CFM's
  98.                  For low humidity areas use      1,661 CFM's
  99.  
  100.    The above figures include outside ventilation of     100 CFM's.
  101.  
  102.    Any cooling unit must be rated as close as possible to the heat gain
  103.    calculated in this study, but not less than that amount.
  104.  
  105. ****************************************************************************
  106.  
  107.                 Enchanted Tree Software - TROUBLESHOOTING Copy
  108.  
  109.                                  Page 2 of 3
  110.  
  111.                          BTU Heating/Cooling Analysis
  112.  
  113.    08-29-1991
  114.  
  115.    John Doe
  116.    1234 Anywhere Ct.
  117.    High Point, NC 27260
  118.  
  119. ****************************************************************************
  120. ****************************************************************************
  121.  
  122.    *********** Commercial analysis based on the following data ***********
  123.  
  124.    There are  18 persons used for this analysis.
  125.  
  126.    This area is being analyzed as a Residence.
  127.  
  128.    There are  10 office equipment units used for this analysis.
  129.  
  130.    There are  40 office lighting units used for this analysis.
  131.  
  132.   *********** Structural analysis is based on the following data ***********
  133.  
  134.    Based on 1055 square feet, total exposed outside wall area.
  135.  
  136.        Wall construction is : 8 - 12 in. block w/19.
  137.        The wall has a heat transfer factor of .048 heating or cooling.
  138.  
  139.    Based on 2 doors, assuming 20 square feet per door.
  140.  
  141.        Door construction is : Solid wood, no storm.
  142.        The door has a heat transfer factor of .713 heating and .46 cooling.
  143.  
  144.    Based on 345 sq. ft. of window glass.
  145.  
  146.        All window construction is : Single glazed, plain, no storm. 
  147.        All windows have a heating factor of  1.505 
  148.  
  149.    There are 75 sq. ft. facing north, with a cooling factor of 30 
  150.    There are 0 sq. ft. facing northeast/west, with a cooling factor of 65 
  151.    There are 195 sq. ft. facing east/west, with a cooling factor of 90 
  152.    There are 0 sq. ft. facing southeast/west, with a cooling factor of 80 
  153.    There are 75 sq. ft. facing south, with a cooling factor of 50 
  154.  
  155.    Based on 1800 square feet total floor area.
  156.  
  157.    The foundation is : Over uncond. basement/enclosed crawl. 
  158.    The floor has a heat transfer factor of .312 heating and 0 cooling.
  159.  
  160.    The ceiling is : Roof on exposed beams or rafters. 
  161.    Ceiling insulation is : R-30. 
  162.    The ceiling has a heat transfer factor of .033 heating and .033 cooling.
  163.  
  164.    This analysis is based on a moisture content of  20  grains.
  165.  
  166. ****************************************************************************
  167.    All heat gain factors above are for a 20 degree differential; all cal-
  168.    culated values are corrected for the applicable temperatures.
  169.  
  170.                 Enchanted Tree Software - TROUBLESHOOTING Copy
  171.  
  172.                                  Page 3 of 3
  173.  
  174.                          BTU Heating/Cooling Analysis
  175.  
  176.    08-29-1991
  177.  
  178.    John Doe
  179.    1234 Anywhere Ct.
  180.    High Point, NC 27260
  181.  
  182. ****************************************************************************
  183. ****************************************************************************
  184.  
  185.                            ****   HEAT LOSSES  ****
  186.  
  187.                  Total wall heat loss of         3,139 BTU's.
  188.  
  189.                  Total window heat loss of      32,191 BTU's.
  190.  
  191.                  Total Door heat loss of         1,768 BTU's.
  192.  
  193.                  Total floor heat loss of       34,819 BTU's.
  194.  
  195.                  Total ceiling heat loss of      3,682 BTU's.
  196.  
  197.                  Miscellaneous heat loss of          0 BTU's.
  198.  
  199.                  Personnel heat gain of          5,400 BTU's.
  200.  
  201.                  Equipment heat gain of          2,000 BTU's
  202.  
  203.                  Lighting heat gain of           3,400 BTU's
  204.  
  205.                            ****   HEAT GAINS  ****
  206.  
  207.      Total wall heat gain of         1,012 BTU's.
  208.  
  209.      Total window heat gain of       2,250 BTU's, NORTHERN exposure.
  210.      Total window heat gain of           0 BTU's, NORTHWEST/EAST exposure.
  211.      Total window heat gain of      17,550 BTU's, EAST/WEST exposure.
  212.      Total window heat gain of           0 BTU's, SOUTHEAST/WEST exposure.
  213.      Total window heat gain of       3,750 BTU's, SOUTHERN exposure.
  214.  
  215.      Total Door heat gain of           368 BTU's.
  216.  
  217.      Total floor heat gain of            0 BTU's.
  218.  
  219.      Total ceiling heat gain of      1,187 BTU's.
  220.  
  221.      Miscellaneous heat gain of      1,600 BTU's.
  222.  
  223.      Personnel heat gain of          5,400 BTU's.
  224.  
  225.      Equipment heat gain of          2,000 BTU's
  226.  
  227.      Lighting  heat gain of          3,400 BTU's
  228.  
  229. ****************************************************************************
  230.    All heat gain amounts above, are for a 20 degree differential. All cal-
  231.    culated values are corrected for the applicable temperatures and duct