home *** CD-ROM | disk | FTP | other *** search
/ Simtel MSDOS 1992 September / Simtel20_Sept92.cdr / msdos / rbbs_pc / bilink15.arc / BILINK.DOC < prev    next >
Text File  |  1990-01-07  |  26KB  |  779 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7.  
  8.  
  9.  
  10.  
  11.  
  12.  
  13.  
  14.  
  15.  
  16.  
  17.  
  18.  
  19.  
  20.                      ╦           ╦                 ╦    ╦
  21.                      ║        ▄  ║       ▄         ╠══╦═╝
  22.                      ╠═════╗  ╦  ║       ╦  ╦═══╗  ║  ╚═╗
  23.                      ║     ║  ║  ║       ║  ║   ║  ║    ║
  24.                      ╚═════╝  ╩  ╚═════  ╩  ╩   ╩  ╩    ╩
  25.  
  26.  
  27.                             VERSION 1.5 - 1/7/90
  28.  
  29.  
  30.                   RBBS-PC Doorway for BiModem File Transfers
  31.  
  32.  
  33.         BILINK Copyright 1989, 1990 by MW Systems, Inc. and M.E. Wittl
  34.                              1998 Lullwater Circle
  35.                            Jonesboro, Georgia  30236
  36.  
  37.  
  38.  
  39.  
  40.  
  41.                       Bimodem Copyright 1989 by Erik Labs
  42.                  RBBS-PC Copyright 1983-1989 by D. Thomas Mack
  43.  
  44.  
  45.  
  46.  
  47.  
  48.  
  49.  
  50.  
  51.  
  52.  
  53.  
  54.  
  55.  
  56.  
  57.  
  58.                                BILINK 1.5 INDEX
  59.  
  60.  
  61.  
  62.  
  63.  
  64.  
  65.  
  66.               Index...........................................  1
  67.  
  68.               Overview/Features...............................  2
  69.  
  70.               Files/Licensing Agreement.......................  3
  71.  
  72.               Installation....................................  5
  73.  
  74.               Configuring Bilink..............................  5
  75.  
  76.               Configuring RBBS-PC.............................  7
  77.  
  78.               Set-Up of RBBS-PC files for BILINK..............  8
  79.  
  80.               Bimodem Configuration...........................  9
  81.  
  82.               Using Bilink.................................... 10
  83.  
  84.               Error Messages.................................. 11
  85.  
  86.               Registration.................................... 12
  87.  
  88.  
  89.  
  90.  
  91.  
  92.  
  93.  
  94.  
  95.  
  96.  
  97.  
  98.  
  99.  
  100.  
  101.  
  102.  
  103.  
  104.                                      - 1 -
  105.  
  106.  
  107.  
  108.  
  109.  
  110.  
  111.  
  112.  
  113.  
  114.  
  115.  
  116. OVERVIEW:
  117.  
  118.  
  119.      Bilink is a doorway program that allows RBBS-PC systems to add 
  120.      Bimodem as an external file transfer protocol as a door on the
  121.      bulletin board.
  122.      
  123.      Bimodem is an outstanding bidirectional file tranfer protocol with
  124.      speeds that rival those of Z-Modem but, with simultaneous uploading
  125.      and downloading of files.  This great protocol will also allow a user
  126.      to "chat" while transfers are taking place.
  127.      
  128.      Bilink has been written for ease-of-use for both the callers and for
  129.      the SYSOP.  Files can be specified either through the Bimodem program
  130.      or through a "create transfer list" routine that is unique to Bilink.
  131.      Once the files have been transfered the caller can return to the Bilink
  132.      Menu or be automatically logged-off the BBS while all RBBS-PC files are
  133.      updated with the file transfer statistics.
  134.  
  135.  
  136.  
  137.  
  138.  
  139.  
  140. FEATURES:
  141.  
  142.  
  143.                *  Easy to Install on RBBS-PC.
  144.  
  145.                *  Com 1 - 4 support.
  146.  
  147.                *  Configured for multiple node operation.
  148.  
  149.                *  Callers can specify files to be transfered from
  150.                   within the Bilink program.  No other Bimodem
  151.                   interface program allows this.
  152.  
  153.                *  Automatic log-off when transfers are complete or 
  154.                   return to board.
  155.  
  156.                *  Updates all RBBS-PC Users and Callers files with
  157.                   file transfer statistics.
  158.  
  159.                *  Monitors carrier and re-starts RBBS if carrier is
  160.                   lost.
  161.  
  162.  
  163.  
  164.  
  165.                                      - 2 -
  166.  
  167.  
  168.  
  169. FILES:
  170.  
  171.  
  172.       BILINK 1.5 includes the following files in this archive:
  173.  
  174.            BILINK.EXE   -  The main doorway program.
  175.  
  176.            BILINK.CFG   -  A sample Bilink configuration file.
  177.  
  178.            BILINK.DOC   -  You are reading it now.
  179.  
  180.            READ.ME      -  Last minute notes.
  181.  
  182.            REGISTER.DOC -  Registration form for Bilink.
  183.  
  184.            1.BAT        -  A sample batch file for running Bilink.
  185.  
  186.            BIDOOR.DEF   -  A sample RBBS def. file for Bilink.
  187.  
  188.            DOORS.DEF    -  A sample door def. file for RBBS door programs.
  189.  
  190.            MENU5        -  A sample door menu for RBBS door programs.
  191.  
  192.            BILIST       -  A sample BIMODEM/BILINK download file list.
  193.  
  194.  
  195.      The Sample files are included to show how Bilink should be set up for
  196.      RBBS.  They can be easily modified to suit your board, or simply include
  197.      the applicable lines in your own files in order to use Bilink.
  198.  
  199.  
  200.  
  201. LICENSING AGREEMENT:
  202.  
  203.      BILINK is Copyright 1989, 1990 by MW Systems, Inc. and M.E. Wittl,
  204.      1998 Lullwater Circle, Jonesboro, Georgia  30236.
  205.  
  206.      BILINK is made available through Shareware on a trial basis only.
  207.      Regular use of BILINK requires registration as described later
  208.      in this manual.  Use of unregistered copies of BILINK by any
  209.      individual, business, corporation, government agency, or any
  210.      other institution is prohibited.  
  211.  
  212.      Registration entitles the user to install BILINK 1.5 on one computer
  213.      at a time.  Each computer using BILINK must have its own registered
  214.      copy of BILINK.
  215.  
  216.      In accordance with the Shareware distribution method, all users
  217.      are granted a limited license to copy BILINK for the trial use
  218.      of others providing that:
  219.  
  220.            - BILINK must be copyied in its original archive form.
  221.  
  222.            - BILINK may not be modified in any way and must be 
  223.              distributed with the full and unmodified documentation
  224.              and registration information.
  225.  
  226.                                      - 3 -
  227.  
  228.  
  229.  
  230.  
  231.  
  232.  
  233. CONTINUATION OF LICENSING AGREEMENT:
  234.  
  235.  
  236.  
  237.  
  238.  
  239.            - BILINK may not be sold or traded for money or any other
  240.              consideration by any party other than MW Systems, Inc. or
  241.              M.E. Wittl.
  242.  
  243.            - BILINK may not be distributed in conjunction with any 
  244.              other product or software without the written consent of
  245.              M.E. Wittl.
  246.  
  247.      Failure to abide by this limited license by sale or modification
  248.      of BILINK is a violation  of the U.S. Copyright Act.  
  249.  
  250.  
  251.  
  252.      Electronic Bulletin Board Systems, PC User Groups and Clubs may 
  253.      add BILINK to their Shareware library subject to the conditions
  254.      above.
  255.  
  256.      Shareware distributors may add BILINK to their libraries subject
  257.      to the conditions above, only after receiving written consent from
  258.      M.E. Wittl.  It must also be prominently stated that:
  259.  
  260.             - BILINK is Shareware.
  261.  
  262.             - BILINK requires registration with MW Systems, Inc.
  263.  
  264.             - BILINK registration is $25.00 payable directly to
  265.               the author: M.E. Wittl, 1998 Lullwater Circle,
  266.               Jonesboro, Georgia  30236.
  267.  
  268.  
  269.  
  270. WARRANTY:
  271.  
  272.  
  273.      MW Systems, Inc., M.E. Wittl, and BILINK make no warranty, expressed
  274.      or implied, concerning this programs merchantability or fitness for
  275.      any particular use.  In no event is MW Systems, Inc. or M.E. Wittl
  276.      liable for any damages resulting from your use of the program.
  277.  
  278.  
  279.  
  280.  
  281.  
  282.  
  283.  
  284.  
  285.  
  286.  
  287.                                      - 4 -
  288.  
  289.  
  290.  
  291.  
  292.  
  293.  
  294.  
  295. INSTALLATION - GENERAL:
  296.  
  297.  
  298.  
  299.      1.)  Make a subdirectory for the BILINK files and un-archive
  300.           BILINK into this subdirectory.  An example of my subdirectory
  301.           for BILINK is:   C:\RBBS\DOORS\BIMOD   This subdirectory contains
  302.           all BILINK and BIMODEM files and is illustrated in the following
  303.           diagram:
  304.  
  305.           
  306.  
  307.                                         ROOT 
  308.                                           │
  309.                                           │
  310.                                     ┌─────┴───────────┬──────┐
  311.           (RBBS Subdirectory)      RBBS             LOTUS   ETC.
  312.                                     │
  313.                         ┌───┬───┬───┴──┬───┬────┐
  314.                         │   │   │      │   │    │
  315.        (Download        1   2   3      4   5    │
  316.         Subdirectories)                       DOORS    (Door Subdirectory)
  317.                                                 │
  318.                                                 │
  319.                                        ┌────────┴────────┐   (Door Programs
  320.                                        │                 │    Subdirectories)
  321.         (BILINK Subdirectory)        BIMOD─┐           CHESS
  322.                                            │ (FILES)
  323.                                            ├ BILINK.EXE
  324.                                            ├ BILINK.CFG
  325.                                            ├ BIMODEM.COM
  326.                                            ├ BIMODEM.CFG
  327.                                            ├ BIBAT.COM
  328.                                            ├ BICONFIG.COM
  329.                                            ├ BIMENU.COM
  330.                                            ├ BISETUP.COM
  331.                                            ├ BIPATH.COM
  332.                                            ├ BILIST  (Download path file)
  333.                                            └ BILINK.DAT (Created by RBBS)
  334.  
  335.  
  336.  
  337. INSTALLATION - CONFIGURING BILINK:
  338.  
  339.  
  340.      2.)  Modify the sample BILINK.CFG to reflect your system.  This file
  341.           is an ASCII text file containing exactly 13 lines each ending
  342.           with a <CR> <LF> sequence.   The information for each line is
  343.           laid out on the following page.
  344.  
  345.  
  346.  
  347.  
  348.                                      - 5 -
  349.  
  350.  
  351.      
  352.  
  353.  
  354. INSTALLATION - BILINK.CFG:
  355.  
  356.  
  357.  
  358.             Line #1:  Complete Drive:\Path\  to the Subdirectory
  359.                       created in step #1.  BE SURE TO END WITH "\".
  360.  
  361.             Line #2:  Complete Drive:\Path\Filename of the BIMODEM
  362.                       file listing of all download directories.  This
  363.                       name is specified when you configure BIMODEM.
  364.                       Do NOT end with a slash.
  365.  
  366.             Line #3:  Complete Drive:\Path\Filename of the RBBS USERS
  367.                       file.  This should be listed exactly as in the
  368.                       RBBS CONFIG utility item #87 - "System file for
  369.                       recording users."  Do NOT end with a slash.
  370.  
  371.             Line #4:  Complete Drive:\Path\Filename of the RBBS CALLERS
  372.                       file.  This should be listed exactly as in the
  373.                       RBBS CONFIG utility item #90 - "System file for
  374.                       'callers'".  Do NOT end with a slash.
  375.  
  376.             Line #5:  Complete Drive:\Path\Filename of the RBBS MESSAGE
  377.                       file.  This should be listed exactly as in the
  378.                       RBBS CONFIG utility item #86 - "System file 
  379.                       containing messages."  Do NOT end with a slash.
  380.  
  381.             Line #6:  Complete Drive:\Path\Filename of the BIMODEM PATH
  382.                       file.  This name is specified when you configure
  383.                       BIMODEM.  The default name is BIMODEM.PTH.  Do NOT
  384.                       end with a slash.
  385.  
  386.             Line #7:  Complete Drive:\Path\Filename of the RBBS UPLOAD
  387.                       description file.  This is the file where file
  388.                       descriptions are posted.  Do NOT end with a slash.
  389.  
  390.             Line #8:  Complete Drive:\Path\ of the subdirectory where
  391.                       new uploads are placed.  BE SURE TO END WITH A "\".
  392.  
  393.             Line #9:  Complete Drive:\Path of the subdirectory where the
  394.                       majority of the RBBS programs reside.  BE SURE TO
  395.                       END WITH A "\".
  396.  
  397.             Line #10: The filename BIMODEM.LOG  .  This does not need a
  398.                       a drive or path and should NOT be changed since it
  399.                       is hardcoded into the BILINK program.
  400.  
  401.             Line #11: The name of your BBS (50 Characters Max.).
  402.  
  403.             Line #12: The First name used to log on as SYSOP.
  404.  
  405.             Line #13: The Last name used to log on as SYSOP.
  406.  
  407.  
  408.  
  409.                                      - 6 -
  410.  
  411.  
  412.  
  413.          
  414. INSTALLATION - CONFIGURING BILINK (CONT):
  415.  
  416.  
  417.  
  418.      EXAMPLE - BILINK.CFG:
  419.  
  420.  
  421.  
  422.                     C:\RBBS\DOORS\BIMOD\             
  423.                     C:\RBBS\DOORS\BIMOD\BILIST
  424.                     C:\RBBS\USERS
  425.                     C:\RBBS\CALLERS
  426.                     C:\RBBS\MESSAGES
  427.                     C:\RBBS\DOORS\BIMOD\BIMODEM.PTH
  428.                     C:\RBBS\NEW\99.DIR
  429.                     C:\RBBS\NEW\
  430.                     C:\RBBS\
  431.                     BIMODEM.LOG
  432.                     Your BBS Name Here
  433.                     MARK
  434.                     WITTL
  435.  
  436.  
  437.  
  438.  
  439.  
  440. INSTALLATION - CONFIGURING RBBS-PC:
  441.  
  442.  
  443.  
  444.      3.)  If your RBBS is currently set-up to run "Doors" you may skip this
  445.           step and continue the installation with step #4.
  446.  
  447.           Run the RBBS-PC utility program "CONFIG".  If you are running
  448.           version CP17.2A or B use the <F6> key to bring up the configuration
  449.           screen for door programs.  
  450.  
  451.           Complete the RBBS-PC configuration questions 101-109.  Question
  452.           #102 should list the complete path/name of "MENU5".  This file was
  453.           sent as a sample in the BILINK package and is the menu screen for 
  454.           door programs.  
  455.  
  456.           Question #109 should list the complete path/name of "DOORS.DEF".
  457.           This file was also sent as a sample in the BILINK package and is
  458.           a control file for door programs.
  459.  
  460.  
  461.  
  462.      4.)  If you are using any of the sample RBBS files included with BILINK,
  463.           move the following files to the main RBBS-PC subdirectory:
  464.  
  465.                *  1.BAT
  466.                *  DOORS.DEF
  467.                *  MENU5
  468.                *  BIDOOR.DEF
  469.  
  470.                                      - 7 -
  471.  
  472.  
  473.  
  474.  
  475.           If you are not going to use the sample RBBS files, simply delete
  476.           them.  Be sure your own files pass the same information in the
  477.           same order as 1.BAT, DOORS.DEF, and BIDOOR.DEF.
  478.  
  479.           SYNTAX for BILINK:    BILINK node        
  480.  
  481.           A.)  1.BAT - EXAMPLE:
  482.  
  483.  
  484.                                @echo off
  485.                                cd \rbbs\doors\bimod
  486.                                bilink %1
  487.                                cd \rbbs
  488.                                rbbs
  489.  
  490.  
  491.                 The Batch file that runs BILINK should pass the NODE as
  492.                 the only parameter.  Note that a slash or dash is NOT to
  493.                 be used before this parameter.
  494.  
  495.  
  496.            B.)  DOORS.DEF - EXAMPLE:
  497.  
  498.  
  499.                    1,20,c:\rbbs\bidoor.def,d,"1.bat [NODE]",N,,{TR
  500.  
  501.  
  502.                 This file is the control file for door programs used
  503.                 by RBBS and is the file designated in RBBS CONFIG
  504.                 question #109.  If you are already running doors on
  505.                 your BBS you can simply add the above line to your
  506.                 DOOR.DEF file. The important parameters that need to
  507.                 be passed are [NODE] and {TR.  All commas are significant.
  508.  
  509.  
  510.            C.)  BIDOOR.DEF - EXAMPLE:
  511.  
  512.  
  513.    c:\rbbs\doors\bimod\bilink.dat,20
  514.    *
  515.    *                                              
  516.    *     ███              ████████████████████████████              ███
  517.    *    ███░              ███████    BILINK    ███████░              ███░
  518.    *   ███░               ███░░░░░░░░░░░░░░░░░░░░░░███░               ███░
  519.    *  ███████████████████████░░   THE BIMODEM    ░░███████████████████████░
  520.    * ██▓▓▓▓▓▓ UPLOAD ▓▓▓▓▓███░░     DOORWAY      ░░███▓▓▓▓ DOWNLOAD ▓▓▓▓███░
  521.    *  ███████████████████████░░   FOR RBBS-PC    ░░███████████████████████░
  522.    *   ███░░░░░░░░░░░░░░░░███░░░░░░░░░░░░░░░░░░░░░░███░░░░░░░░░░░░░░░░███░
  523.    *    ███░              ████████████████████████████░              ███░
  524.    *     ███░             ████████████████████████████░             ███░
  525.    *      ░░░              ░░░░░░░░░░░░░░░░░░░░░░░░░░░░              ░░░
  526.    *                                            
  527.    *
  528.    *
  529.    *Loading BILINK...
  530.    :
  531.                                      - 8 -
  532.  
  533.  
  534.  
  535.  
  536.  
  537.            D.)  MENU5 - EXAMPLE:
  538.  
  539.  
  540.  
  541.  
  542.     ██████ Door Programs ██████████████████████████████████████████████████████
  543.     █                                                                         █
  544.     █                        █▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀█                          █
  545.     █                        █                     █                          █
  546.     █   1 - BiLink BiModem   █   █▀▀▀▀▀▀█▀▀▀▀▀▀█   █                          █
  547.     █       Transfer Door.   █   █      █      █   █                          █
  548.     █                        █   █      █      █   █                          █
  549.     █                        █   █▄▄▄▄▄▄█▄▄▄▄▄▄█   █                          █
  550.     █                        █   █      █      █   █                          █
  551.     █                        █   █      █      █   █                          █
  552.     █                        █   █▄▄▄▄▄▄█▄▄▄▄▄▄█   █                          █
  553.     █                        █                   O █                          █
  554.     █                        █                     █                          █
  555.     █                        █                     █                          █
  556.     █                        █                     █                          █
  557.     █                        █                     █                          █
  558.     █▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄█                     █▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄█
  559.  
  560.  
  561.  
  562.  
  563.  
  564.  
  565.  
  566. INSTALLATION - BIMODEM CONFIGURATION:
  567.  
  568.  
  569.      5.)  Get the latest copy of BIMODEM and install it according to the
  570.           BIMODEM directions in the BILINK directory.
  571.  
  572.           The following BIMODEM files are all that are needed:
  573.  
  574.                *  BIMODEM.COM
  575.                *  BIMODEM.CFG
  576.                *  BIPATH.COM
  577.                *  BIBAT.COM
  578.                *  BICONFIG.COM
  579.                *  BIMENU.COM
  580.                *  BISETUP.COM
  581.  
  582.  
  583.      6.)  Configure BIMODEM to suit your needs; however, be sure to leave
  584.           the log file name blank and answer NO to both log file questions.
  585.  
  586.  
  587.  
  588.      7.)  Use the name BILIST for the file that contains the list of all
  589.           download directory path names.
  590.  
  591.  
  592.                                      - 9 -
  593.  
  594.  
  595.  
  596.  
  597.  
  598.  
  599. INSTALLATION - BIMODEM CONFIGURATION (CONT):
  600.  
  601.  
  602.  
  603.  
  604.      8.)  Create an ASCII text file called BILIST and enter all download
  605.           directory drive:\paths in this file.  End each path with a "\"
  606.           and each line should end with a <CR> <LF> sequence.
  607.  
  608.           EXAMPLE:  
  609.  
  610.                           c:\rbbs\1\
  611.                           c:\rbbs\2\
  612.                           c:\rbbs\3\
  613.                           c:\rbbs\4\
  614.                           c:\rbbs\5\
  615.                           c:\rbbs\6\
  616.                           c:\rbbs\7\
  617.                           c:\rbbs\new\
  618.  
  619.            This is the list BIMODEM and BILINK will use to search for
  620.            download requests.  
  621.  
  622.  
  623.  
  624.  
  625.  
  626. USING BILINK:
  627.  
  628.      
  629.  
  630.      Callers who wish to use the BIMODEM file transfer protocol select
  631.      the BILINK door from MENU5 or from your own RBBS door menu.  The
  632.      node is passed to the BILINK program and RBBS handles the callers time
  633.      in the doorway.
  634.  
  635.      The BILINK program gets certain operating information from the RBBS
  636.      system files, and caller information from the DORINFO#.DEF file that
  637.      RBBS produces.  Callers will need ANSI to use the BILINK program since
  638.      it uses "escape" sequences for the display.
  639.  
  640.      When the BILINK program starts, the caller is presented with a menu
  641.      with the following selections:
  642.  
  643.  
  644.  
  645.          *  (B)imodem File Transfer  -  Used to start the BIMODEM transfer
  646.                                         after files have been specified.
  647.                                         This selection will return the
  648.                                         caller to the menu after the
  649.                                         transfer is complete.
  650.  
  651.  
  652.  
  653.                                     - 10 -
  654.  
  655.  
  656.  
  657.  
  658.  
  659.  
  660. USING BILINK (CONT):
  661.  
  662.  
  663.  
  664.          *  (T)ranfer and Log Off    -  Used to start the BIMODEM transfer
  665.                                         after files have been specified.
  666.                                         This selection will log the caller
  667.                                         off after the transfer is complete.
  668.                                         The log-off count down can be 
  669.                                         cancelled by the caller or the SYSOP.
  670.  
  671.          *  (C)reate Transfer List   -  Used to create a transfer list of
  672.                                         files for uploading or downloading.
  673.                                         The caller can enter filenames to
  674.                                         download and/or complete path names
  675.                                         of upload files.  For uploads, the
  676.                                         caller is also prompted for upload
  677.                                         file descriptions.  After files have
  678.                                         been designated the caller is returned
  679.                                         to the main BILINK menu to begin the
  680.                                         transfer.
  681.  
  682.          *  (Q)uit Back to BBS       -  Used to return to the main BBS 
  683.                                         program.
  684.  
  685.     
  686.  
  687.  
  688.      Upon completion of the BIMODEM transfer, BILINK will update all RBBS
  689.      system files for number of uploads, downloads, and bytes transferred.
  690.      It will also update the upload file list with any upload file descipt-
  691.      ions and will place uploads in the upload directory.
  692.  
  693.      
  694.  
  695.  
  696.  
  697. BILINK ERROR MESSAGES:
  698.  
  699.  
  700.   
  701.  
  702.      BILINK will create an error file called BILINK.ERR in the event of any
  703.      file errors.  Please report the contents of this file to MW Systems, Inc.
  704.    
  705.      Most non-critical errors will allow the caller to continue with the file
  706.      transfer after first acknowledging with a key-press.  Critical errors
  707.      will simply abort the BILINK program and return the caller to RBBS.
  708.  
  709.  
  710.  
  711.  
  712.  
  713.  
  714.                                     - 11 -
  715.  
  716.  
  717.  
  718.  
  719.  
  720.    BILINK is Copyright (c) 1989,1990 by MW Systems, Inc. and M.E. Wittl
  721.  
  722.    Use of BILINK requires registration.
  723.  
  724.    Print and send this form along with your check or money order.
  725.  
  726. ------------------------------------------------------------------------------
  727. |                                                                            |
  728. |    Registration Form for BILINK 1.5:  RBBS Doorway for BIMODEM.            |
  729. |                                                                            |
  730. |                                                                            |
  731. |  Name: ___________________________________________________________________ |
  732. |                                                                            |
  733. |  Name to Appear on Registration: _________________________________________ |
  734. |                                                                            |
  735. |  Address: ________________________________________________________________ |
  736. |                                                                            |
  737. |  City: _____________________  State/Prov: _______ Zip/Code: ______________ |
  738. |                                         _               _                  |
  739. |  Phone: (_______) ______-____________  |_| Voice #     |_| Data #          |
  740. |                                                                            |
  741. |                                                                            |
  742. |   By filling out information in this form, and enclosing a check or        |
  743. |   money order, I hereby certify that I will use the BILINK program         |
  744. |   on a single computer.  I will not make unauthorized copies of BILINK     |
  745. |   or modify the program in any way including removing the copyright        |
  746. |   notice.                                                                  |
  747. |                                                                            |
  748. |                                                                            |
  749. |   Signature: ____________________________ Date: ____/____/____             |
  750. |                                                                            |
  751. |                                                                            |
  752. |   Price List:                                                              |
  753. |                                                                            |
  754. |  _                                                                         |
  755. | |_| BILINK 1.5 Registration .(each copy)...............  $ 25.00 (U.S.)    |
  756. |                                                                            |
  757. |                                                                            |
  758. |                                           Total Enclosed:  ____________    |
  759. |                                                                            |
  760. |     A registered Master Diskette will be sent to you for each copy         |
  761. |     ordered.                                                               |
  762. |                                                                            |
  763. |                                                                            |
  764. |                                                                            |
  765. |     Make Checks payable to:    Mark Wittl                                  |
  766. |                                1998 Lullwater Circle                       |
  767. |                                Jonesboro, Georgia  30236                   |
  768. |                                U.S.A.                                      |
  769. |                                                                            |
  770. |                                                                            |
  771. ------------------------------------------------------------------------------
  772.  
  773.  
  774.  
  775.                                     - 12 -
  776.  
  777.  
  778.  
  779.