  1.                   STANDARD MICROSYSTEMS CORPORATION
  2.  
  3.                 Novell NetWare 386 v4.x Server Driver
  4.          For EtherPower, EtherPower^2, and the EtherPower 10/100 Family
  5.                         of PCI Network Adapters
  6.  
  7.                           INSTALLATION GUIDE
  8.  
  9.    This software is licensed by SMC for use by its customers only.
  10.         Copyright (c) 1996 Standard Microsystems Corporation.
  11.                          All rights reserved.
  12.  
  13.  
  14. This installation guide describes:
  15.  
  16. o  An overview
  17.  
  18. o  Supported adapters
  19.  
  20. o  Preinstallation hardware and software requirements
  21.  
  22. o  Supplied files
  23.  
  24. o  Adapter installation notes
  25.  
  26. o  Using EZStart to copy the Novell NetWare 386 v4.x server 
  27.    driver (SMCPWR.LAN) from the SuperDisk to your server
  28.  
  29. o  Loading the LAN driver and establishing a network connection
  30.  
  31. o  Driver command line parameters
  32.  
  33. o  Installing multiple adapters
  34.  
  35. o  Troubleshooting
  36.  
  37. o  Error messages
  38.  
  39.  
  40. OVERVIEW
  41.  
  42. This file explains how to install and load the Novell NetWare 386
  43. v4.x server driver.
  44.  
  45.  
  46. SUPPORTED ADAPTERS
  47.  
  48. o  EtherPower Ethernet PCI adapters (8432 board types)
  49. o  EtherPower^2 Dual-Channel PCI Ethernet adapters (8434 board types)
  50. o  EtherPower 10/100 Fast Ethernet PCI adapters (9332 board types)
  51.  
  52.  
  53. PREINSTALLATION HARDWARE AND SOFTWARE REQUIREMENTS
  54.  
  55. Hardware Requirements:
  56.  
  57. - An IBM-compatible personal computer with 80386 or higher
  58.   microprocessor and PCI bus supporting bus master mode.
  59.  
  60. - An EtherPower, EtherPower^2, OR EtherPower 10/100
  61.   PCI adapter for that bus.
  62.  
  63. Software Requirements:
  64.  
  65. - Novell NetWare 386 v4.x
  66.  
  67.  
  68. SUPPLIED FILES
  69.  
  70. General files
  71.  
  72. o  INSTALL.DOC      This file.
  73. o  RELEASE.DOC      Release notes for this version of the driver.
  74.  
  75. Files to install the Novell NetWare 386 v4.x driver
  76.  
  77. o  SAMPLE.4X
  78. o  SMCPWR.LAN
  79. o  SMCPWR.LDI
  80. o  SMCNLM.EXE     Self-extracting *NLM Server software for basic
  81.                                    connectivity.
  82.  
  83. * NLM files are copyrighted by Novell. Do not distribute these 
  84.   files without permission from Novell.
  85.  
  86.  
  87. ADAPTER INSTALLATION NOTES
  88.  
  89. Refer to the user guide for complete installation instructions.
  90.  
  91. When installing an SMC PCI adapter in a PCI computer, make sure
  92. the slot you select supports bus master operations.
  93.  
  94. o  Motherboards with bus master jumpers and interrupt jumpers for 
  95.    PCI slots:
  96.  
  97.    1. Enable bus master operations to the selected PCI slot using the
  98.       appropriate motherboard jumper.
  99.    2. Select interrupt to the selected PCI slot using the appropriate
  100.       motherboard jumper.
  101.    3. Enter the computer's setup menu and:
  102.       - Enable bus master on the PCI slot.
  103.       - Enable I/O on the PCI slot.
  104.       - Define interrupt number on the PCI slot.
  105.  
  106. o Motherboards with automatic PCI parameterization:
  107.  
  108.    1. No specific setup is needed.
  109.  
  110.  
  111. EtherPower 10/100 Users Only:
  112.  
  113.       Ensure that the data rate (10 Mbps [MB10] or 100 Mbps [MB100])
  114.       configured for the adapter matches the speed of the hub to which
  115.       it is attached. 
  116.  
  117. EtherPower 10/100 B Only:
  118.  
  119.       This adapter supports NWAY (Auto-Negotiation). Setting the 
  120.       SIA_MODE to AUTOSENSE will allow the driver to automatically 
  121.       detect the line speed (10 Mbps [MB10] or 100 Mbps [MB100]) and 
  122.       operate at the highest possible data rate.
  123.  
  124.       The methods used to manually specify the data rate of the adapter
  125.       will vary depending on your networking software, the driver 
  126.       being used, and the hub (or concentrator) you are connecting to.
  127.       All SMC drivers for the EtherPower 10/100 B adapter support five
  128.       different data rate settings.
  129.  
  130.       AUTOSENSE -  when using this default setting, the driver
  131.       will automatically detect the line speed of the attached hub 
  132.       and set the adapter to operate at the highest possible data rate
  133.  
  134.       10 Mbps
  135.       Full duplex - adapter operates at 10 Mbps only
  136.  
  137.       10 Mbps
  138.       Half duplex - adapter operates at 10 Mbps only
  139.  
  140.       100 Mbps
  141.       full duplex - adapter operates at 100 Mbps only
  142.  
  143.       100 Mbps
  144.       half duplex - adapter operates at 100 Mbps only
  145.  
  146.  
  147. COPYING THE DRIVER FILES
  148.  
  149. From the Driver Installation screen, select 'Copy Files' to copy all 
  150. the files used by this driver from the SuperDisk to the Destination
  151. Directory recommended by EZStart, or to a different directory that 
  152. you specify.
  153.  
  154.  
  155. LOADING THE DRIVER
  156.  
  157. Installing the LAN driver is part of the NetWare installation 
  158. process. Use the following instructions with those 
  159. in the NetWare 386 installation manual to install the driver. 
  160. You will need the SuperDisk during this procedure.
  161.  
  162. 1. Refer to the "Load LAN driver module" section in the Novell 
  163.    NetWare 386 v4.x installation manual for instructions on 
  164.    installing NetWare.
  165.  
  166. 2. Follow the instructions on starting NetWare and configuring 
  167.    the server. Use the Load command to load the LAN driver.
  168.    If the LAN driver is not located in the default directory,
  169.    specify the path to the file on the command line. The 
  170.    Load command will prompt you for configuration parameters 
  171.    if they are not supplied on the command line. 
  172.  
  173.    The Load command line parameters may be saved in an 
  174.    AUTOEXEC.NCF file, so they execute automatically every time 
  175.    the server starts. Refer to the NetWare 386 installation 
  176.    manual on how to create an AUTOEXEC.NCF file.
  177.  
  178. 3. From the command line on the server, type: LOAD MSM.NLM.
  179.  
  180. 4. Press the Enter key to load MSM.NLM.
  181.  
  182. 5. From the command line on the server, type: LOAD ETHERTSM.NLM.
  183.  
  184. 6. Press the Enter key to load ETHERTSM.NLM.
  185.  
  186.    Note: The following steps are specific to loading SMCPWR.LAN.
  187.          For examples, please refer to the SAMPLE.4X demo file on
  188.          this diskette.
  189.  
  190.          ETHERPOWER 10/100 USERS ONLY:
  191.  
  192.          Default line speed of the adapter is 100 Mbps. To change the
  193.          line speed to 10 Mbps, add the following to the command line
  194.          load string:
  195.  
  196.          "LOAD SMCPWR LINE_SPEED=10"
  197.  
  198. 7. If the adapter is installed into PCI slot 17, add the following
  199.    command line load string:
  200.  
  201.    "LOAD SMCPWR SLOT=17"
  202.  
  203. 8. At this point, a protocol must be bound to the driver. For example:
  204.  
  205.    BIND IPX TO SMCPWR NET=XX
  206.  
  207.    where xx is the logical network address for the frame type
  208.    indicated in your load command.
  209.  
  210.  
  211. DRIVER COMMAND LINE PARAMETERS
  212.  
  213.    The only required parameter is the slot number if the adapter is
  214.    not installed in slot 3.
  215.  
  216.    Example: load C:SMCPWR SLOT=4<Enter> 
  217.  
  218.    ISA/EISA slots for this driver are counted from 1 to 15, PCI slots 
  219.    for this driver are counted from 3. The first PCI adapter installed 
  220.    in your computer will be treated as if it is installed in slot 3, 
  221.    the next one will be in slot 4, and so on.
  222.    
  223.  
  224. INSTALLING MULTIPLE ADAPTERS
  225.  
  226. If you have only one PCI adapter in the server, there is no need to
  227. specify slot number in the LOAD command line. If there is more than
  228. one PCI adapter, the driver will detect it and ask you for a slot
  229. selection, or you can specify slot number in the LOAD command line.
  230. For examples, please refer to the SAMPLE.4X demo file on this 
  231. diskette.
  232.  
  233.  
  234. TROUBLESHOOTING
  235.  
  236. If you experience excessive 'Tx FIFO Underflow' or 'Rx FIFO 
  237. Overflow' counts in your server Monitor program in the LAN/WAN menu 
  238. in your driver custom counters, and you have a PCI computer with 
  239. Saturn or Mercury chipset, try using the TURBO keyword when you 
  240. load your driver.
  241.  
  242. Example:
  243.  
  244.      load SMCPWR frame=ethernet_II TP TURBO
  245.  
  246. Note that some PCI computers may not correctly support 32-bit 
  247. protected mode PCI bios calls. To load the driver on these 
  248. computers, use the BIOS16 keyword in the driver invocation line. 
  249. This will cause the driver to access the computer's BIOS in real 
  250. mode fashion.
  251.  
  252. Note that accessing the PCI BIOS in 32-bit protected mode is the 
  253. native mode in 32-bit protected mode operating systems.
  254.  
  255.  
  256. ERROR MESSAGES
  257.  
  258. o 50 - No EISA nor PCI board found in machine!
  259.  
  260.   Driver could not detect a supported adapter.
  261.  
  262. o 73 - Unable to allocate memory
  263.  
  264.   Driver failed to allocate needed memory from the operating system
  265.   (receive/transmit descriptors or needed transmit buffers).
  266.  
  267. o 200 - Timeout when initializing DecChip 21X4 with setup packet!
  268.  
  269.   Occurs when the PCI slot does not support DMA. Check that BIOS 
  270.   setup or motherboard switches are set to enable DMA and/or bus 
  271.   master operation for the slot.
  272.  
  273. o 210 - Driver failed to locate either EISA or PCI bus!
  274.  
  275.   The computer is not identified as an EISA- or PCI-bus computer.
  276.  
  277. o 213 - Unexpected OS behavior. Driver supports 3.11 and later
  278.  
  279.   Identifies a failed assumption regarding the operating system 
  280.   behavior.
  281.  
  282. o 227 - Internal CRC table corrupted
  283.  
  284.   Driver found an error in internal CRC table.
  285.  
  286. o 228 - Could not handle chipset bug workaround successfully
  287.  
  288.   Failed to operate chipset bug workaround because PCI BIOS returned
  289.   a fail status in one of the calls that operates this mechanism.
  290.  
  291. o 229 - This machine Host to PCI bridge has a known bug. Driver 
  292.   limits DC21X4 bursts as a workaround.
  293.  
  294.   This message indicates that your computer does not correctly 
  295.   support the PCI Local Bus Specification (v2.0). The SMC driver 
  296.   will work in this environment, but you are urged to contact the 
  297.   computer manufacturer to determine if your BIOS correctly supports 
  298.   the features of the PCI Local Bus Specification (v2.0).
  299.  
  300. o 240 - Unable to locate or read the Ethernet ROM address on board!
  301.  
  302.   Could be caused by corrupt data stored in the IEEE serial ROM.
  303.  
  304. o 244 - Serial ROM-Read Failed
  305.  
  306.   Driver failed to read the IEEE serial flash ROM due to hardware
  307.   handshake failure. Make sure the IEEE flash ROM on your adapter
  308.   is operational using EZStart's Basic Adapter Test.
  309.  
  310.  
  311. This commercial computer software and documentation is provided with
  312. RESTRICTED RIGHTS.  Use, duplication, or disclosure by the
  313. Government is subject to restrictions set forth in subparagraph
  314. (c) (1) (ii) of the Rights in Technical Data and Computer Software
  315. clause at DFARS 252.227-7013, or subparagraphs (c) (1) and (2) of the
  316. Commercial Computer Software -- Restricted Rights clause at
  317. FAR 52.227-19, or Alternate III of the Rights in Data -- General
  318. clause at FAR 52.227-14, as applicable.  The manufacturer /
  319. subcontractor is Standard Microsystems Corporation,   80 Arkay Drive,
  320. Hauppauge,  NY    11788. 
  321.  
  322. SMC and Standard Microsystems are registered trademarks; and EtherPower,
  323. EtherPower^2, EtherPower 10/100, EtherPower 10/100 B, EZStart, and 
  324. SuperDisk are trademarks of Standard Microsystems Corporation. Other 