  1. SB-007
  2.  
  3. Service Notes on T-599A/D                            11-2-77
  4.  
  5. 1.  No ALC - Drive 10 Meters: Check for loose contact at
  6.     oscillator wafer on coil pack.
  7.  
  8. 2.  No TX any band:  Check T-1 on generator board 
  9.     (X52-0009-00).
  10.  
  11. 3.  No TX:  Bad driver FET Q1 3SK22 (GR) on X47-0004-00.
  12.  
  13. 4.  No relay action when TX:  Bad Q8 2SA562 (Y).  When 
  14.     replacing Q8 change resistor R16 to 4.7 ohms.
  15.  
  16. 5.  Rubber belt slipping on drive and load.  TKC has chain
  17.     modification kit.
  18.  
  19. 6.  No drive when shock:  Check for loose output terminal at 
  20.     carrier unit (X50-0002-00).
  21.  
  22. 7.  Low Power 75 Meters:  Check for shorting terminals at
  23.     final rotary switch (S10-1002-05).
  24.  
  25. 8.  No output on any band:  Check T-2 on GEN unit (X42-0009-00).
  26.  
  27. 9.  No TX:  Check final relay for burned contacts.  (S51-4017-15).
  28.  
  29. 10. Bias current too high and blows fuse.  Check for bad S-2001A and
  30.     shorted cathode resistors, 10 ohm.
  31.  
  32. 11. Cannot neutralize:  Make sure shield is properly installed on driver
  33.     12BY7A.
  34.  
  35. 12. No output from generator unit (X52-0009-00):  Bad Q4 TA7045.
  36.  
  37. 13. No 9 volt out at AVR (X43-010-00):  Check Q1 2SA606 (L).
  38.  
  39. 14. Low output power:  If American 12BY7 is used in driver circuit, this
  40.     can cause parasitic oscillation.  Please use standard Kenwood
  41.     replacement tubes.
  42.  
  43. 15. Blows Fuse:  Check for shorted electrolytics at power supply 
  44.     (X43-011-00).
  45.  
  46. 16. AC hum on SSB transmission: Send for TKC bulletin.
  47.  
  48. (c) 11277TKC
  49.  
  50. Downloaded From P-80 International Information Systems 304-744-2253