home *** CD-ROM | disk | FTP | other *** search
/ Hacker Chronicles 2 / HACKER2.BIN / 618.PARAFIL.DOC < prev    next >
Text File  |  1989-01-27  |  9KB  |  180 lines

  1.                               
  2.  
  3.  
  4.  
  5.  
  6.  
  7.  
  8.  
  9.                               P A R A F I L . E X E
  10.                                
  11.                       A PARAGON MEMORY CHANNEL FILE UTILITY
  12.       
  13.                                  C A U T I O N !
  14.       
  15.                     THE PROGRAM ASSUMES THAT THE RADIO IS ON.
  16.                     DO NOT LEAVE THE RADIO IN ANY WAIT STATE.
  17.       
  18.               Use the ESCAPE key to EXIT a function when uncertain.
  19.       
  20.               This program can be used as a stand along program for
  21.               memory  management or as a complete  utility  for the
  22.               radio. If you do not have a serial board installed DO
  23.               NOT try to Connect to the radio.
  24.       
  25.         RECORD DATA:  Each PMF file can contain 62 memories. Each  memory
  26.         record is 24 bytes or 1,488 bytes for each file.
  27.  
  28.       
  29.                              I N S T A L L A T I O N
  30.                          -------------------------------
  31.              Type  PARAFIL <ENTER>. On startup you will be asked for  the
  32.         following four entries for the PARAGON.USR file:
  33.        
  34.              Callsign:  Enter your call.  The  letters A-Z, numerals 0-9,
  35.                         and  the slash '/' are to be used in  the  normal
  36.                         convention.
  37.            Fast Delay:  .477 is the default value.
  38.           Voice Delay:  8.1 is the default value.
  39.           Verify: "Y":  Verify enabled or ON. The program will prompt the
  40.                         the  user either before or after an entry.  It is
  41.                         suggested  that  the  default value be used until
  42.                         you are accustomed to the program.    
  43.                   "N":  Verify disabled, almost all of the  prompts  will
  44.                         be OFF.  The  ERASE all  memory  query  is always
  45.                         ON.  Follow  the prompts. The  main  screen  will
  46.                         show the state of the above.
  47.  
  48.              If you give the program to someone else, or later find  that
  49.         the file needs to be changed, just delete it and run the program.
  50.         This file is used for two programs, PARAFIL and PAR-XL.
  51.              The program assumes that the PARAGON.USR file along with any
  52.         .PMF memory files are in the current directory and/or drive.
  53.      
  54.         Page1
  55.                           
  56.                               * PARAFIL MAIN MENU *
  57.                ╔═════════════════════════════════════════════════╗
  58.                ║  C)onnect to PARAGON        O)pen a PFM file    ║
  59.                ║  A)dd to memory file        E)dit memory file   ║
  60.                ║  L)oad PMF file             P)rint memory file  ║
  61.                ║  S)ave PARAGON memories     Q)uit    Verify     ║
  62.                ╚═════════════════════════════════════════════════╝
  63.         CONNECT:
  64.              Opens  the  serial port (COM1:), extracts,  and  prints  the
  65.         current data in the status frame.
  66.  
  67.         OPEN:
  68.              Enter the file name with no extension. If no name is entered
  69.         the   default  name  PARAGON.PMF is used. When a file  is  opened
  70.         any previous file loaded will be closed.
  71.  
  72.         ADD:
  73.              The  add screen will appear along with the next record  num-
  74.         ber.  No duplicate channel numbers are allowed.  Please  remember
  75.         that  the  channel number takes  precedence  over  the  frequency
  76.         when using the scan/memory tune function/s. All but  the   alpha-
  77.         numeric  tag  has to be entered. When  entering the  frequency  a
  78.         decimal  need  not  be entered for a whole number  and  only  one
  79.         decimal  is  allowed, formatting is automatic. The  frequency  is
  80.         also retained for the next record as a reminder. The default  for
  81.         MODE is  USB, and the crystal FILTER is 6.0.  See EDIT below.
  82.              When the record is correct "F10= Confirm  ESC= Exit" will be
  83.         appear. On pressing F10 you will be asked to either S)ave, E)dit,
  84.         or Q)uit. If saved the record will be written, form cleared,  and
  85.         ready  for  the next entry. Upon exiting, if  any  records  where
  86.         added, an indexing will take place.
  87.  
  88.         EDIT:
  89.              The  program  uses only the over-type  mode  while  editing.
  90.         Please  use the below editing commands. If you are in the  middle
  91.         of a edit and you wish to exit, put the cursor on the first field
  92.         and press F10 or ESC.
  93.  
  94.                             CURSOR MOVEMENT COMMANDS:
  95.                                 [PgUp] - Move to the first field
  96.                                 [PgDn] - Move to last field
  97.         [DnAr],[Tab],[Enter],[^M],[^X] - Move down a field
  98.                            [UpAr],[^E] - Move up a field
  99.                            [^S],[LfAr] - Move a character left
  100.                            [^D],[RtAr] - Move a character right
  101.                             [^F],[End] - Move to end of field
  102.                            [^A],[Home] - Move to beginning of field
  103.                          
  104.                           DATA INSERT/DELETE COMMANDS:
  105.                  [Del],[BSP],[^G],[^H] - delete a single character
  106.                                   [^Y] - delete entire line
  107.                                   [^T] - delete to end of line
  108.                                  [Ins] - insert space at cursor position
  109.  
  110.              If  a field was changed while editing a check mark  will  be
  111.         placed  at the side of the field. If a mistake was made  and  you
  112.         wish to restore the field to the original entry do the following:
  113.              1. Go to the field to be restored.
  114.              2. Press ^Y to clear it.
  115.              3. Press <ENTER> and the original entry will be shown.
  116.                 This feature is not available for the alpha tag. (more)
  117.     
  118.         Page 2
  119.          
  120.              After  you edit a record  you will be  asked for an  OK,  if
  121.         so, then it will be rewritten. If the channel number was changed,
  122.         and  no duplicate was found, you will again be asked for  an  OK.
  123.         Just an added precaution. Follow the prompts. See ADD above.
  124.       
  125.              Note: No entry deletion is available. You can use the PAR-XL
  126.         program,  or manually erase a memory channel/s and then save  the
  127.         new version. Experiment.
  128.  
  129.         LOAD:
  130.              Used  to load a .PMF file into the PARAGON. When a  file  is
  131.         loaded  into memory only the channels in the file are  used.  Any
  132.         memory channel in memory of a different number are unaffected.
  133.       
  134.         PRINT Console / Printer:
  135.              Console:  Listing is by channel number only.
  136.              Printer:  You can list by records,  frequency,  or by memory
  137.         channel number.
  138.       
  139.         SAVE:
  140.              Enter the name of the memory file or us the default name. If
  141.         a  file  exists with the same name you be  notified.  All  memory
  142.         channels  are read, checked, and if in use written to the  file.
  143.         The format is the same as Sto-Enter. Patience OM.
  144.            
  145.         QUIT:
  146.              You guessed it!
  147.  
  148.         ERASE:
  149.              The erase all PARAGON memory function is activated by press-
  150.         ing ^Z. All the memory channels will be cleared from the PARAGON,
  151.         whether in use or not. If you use the PAR-XL program  after doing
  152.         a complete erasure, DO NOT USE THE MEMORY TUNE MODE. Enter two or
  153.         memories before using this function. The scratch-pad channel (62)
  154.         will remain in memory, if entered.
  155.              A  PARAGON  memory file is indexed/sorted  twice  under  the
  156.         following  conditions: when it is loaded, if any  additional  re-
  157.         cord/s where added, and after an editing session.
  158.  
  159.         Timing:
  160.              If  an  hangup  occurs try changing  the  fast/voice values.
  161.         DO NOT LEAVE THE  PARAGON  IN A WAIT STATE.  Complete any  manual
  162.         operations before using any software function. Run the program on
  163.         disk called 'TIMDEF' to check against your machine.
  164.       
  165.         Printer:
  166.              The program uses the following codes;
  167.                        ASCII code:   SI (Select condensed)
  168.                           Decimal:   15
  169.                        ASCII code:  DC2 (Cancel condensed)
  170.                           Decimal:   18
  171.                        ASCII code:   FF (Form feed)
  172.                           Decimal:   12
  173.         Comments:
  174.              Please address any comments or ideas to:
  175.              J. F. Masur, Route 2, Box 855, Perkins, OK 74059
  176.                           
  177.         Signed "Joe" KD5LQ                                        1/27/89
  178.  
  179.  
  180.